Brand: Endress+Hauser (E & H)
Endress+Hauser 8H5B Promass H 500 Corrosion-Resistant Flowmeter
Description
Why buyers search for 8H5B: tantalum and zirconium Coriolis measurement
When a line carries hot acid, chlorinated solvent or another medium that attacks stainless steel, the Endress+Hauser 8H5B is the Coriolis meter that the manufacturer positions for the job. TI01283D describes the Proline Promass H 500 as a chemically resistant single-tube flowmeter, in a remote version with up to 4 I/Os. Its measuring tube is made of zirconium or tantalum, so wetted metal resists far more aggressive fluids than the stainless tubes in the E or F series.
The remote transmitter is the other half of the pitch: it can be mounted away from corrosive atmospheres and from heat, and it connects through a standard cable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; we supply the 8H5B against a full order code supplied by you.
Features of the 8H5B at a glance
- Zirconium 702 or tantalum 2.5W measuring tube for corrosion-resistant wetted parts
- Nominal diameters from DN 8 to 50, with medium temperature up to 205 degC for zirconium
- Liquid mass flow accuracy of 0.10 % of reading and repeatability of 0.05 %
- Remote transmitter, up to four I/Os, touch display with WLAN access
- Heartbeat Technology for verification
- Multivariable output: flow, density and temperature from one point
8H5B data sheet values
The figures that follow are taken from the technical information. Full scale values apply to the tantalum version, as the datasheet itself notes; confirm zirconium ranges in the document before ordering.
| Parameter | Value for 8H5B |
|---|---|
| Product root | 8H5B, Proline Promass H 500 (TI01283D, 2025-11-11) |
| Sensor design | Single-tube sensor, remote transmitter, standard cable |
| Measuring tube materials | Zirconium 702 (UNS R60702) or tantalum 2.5W |
| Nominal diameters | DN 8 to 50 (3/8 to 2 inch): 8, 15, 25, 40, 50 |
| Full scale, tantalum DN 8 | 0 to 2 000 kg/h |
| Full scale, tantalum DN 15 | 0 to 6 500 kg/h |
| Full scale, tantalum DN 25 | 0 to 18 000 kg/h |
| Full scale, tantalum DN 40 | 0 to 45 000 kg/h |
| Full scale, tantalum DN 50 | 0 to 70 000 kg/h |
| Liquid mass and volume flow accuracy | Plus/minus 0.10 % of reading |
| Gas mass flow accuracy | Plus/minus 0.50 % of reading (tantalum) |
| Liquid density accuracy | 0.0005 g/cm3 reference; 0.02 g/cm3 standard; 0.002 g/cm3 with Special density package EE |
| Repeatability, liquids | Plus/minus 0.05 % of reading; gases 0.25 % (tantalum) |
| Medium temperature, zirconium | -50 to +205 degC (-58 to +401 degF), option DA |
| Medium temperature, tantalum | -50 to +150 degC (-58 to +302 degF), option EA |
| Medium density | 0 to 5 000 kg/m3 |
| Process connections | Fixed flanges: EN 1092-1 (DIN 2501), EN 1092-1 (DIN 2512N), ASME B16.5, JIS B2220 |
| Transmitter housings | Polycarbonate, coated aluminum AlSi10Mg, or cast stainless 1.4409 (CF3M) |
| Transmitter weight | 1.4 kg digital polycarbonate; 2.4 kg digital aluminum; 6.5 kg aluminum; 15.6 kg cast stainless |
| Sensor weight, PN 40 flanges | DN 8: 10 kg; DN 15: 11 kg; DN 25: 17 kg (aluminum connection housing) |
| Cast housing add-on | Plus 3.7 kg for stainless cast sensor connection housing |
| Hazardous area | EPL Gb, Zone 1 in the measuring tube for the listed approval and electronics codes |
| Current output | 4 to 20 mA HART, load 250 to 700 ohm, 0.38 microampere resolution |
Typical duties for the 8H5B in the Gulf
Petrochemical and chemical sites on the Omani coast handle hydrochloric, sulfuric and organic acids, bromine-based compounds and chlorinated intermediates. These are the services in which a tantalum tube pays back. Fertilizer and specialty chemical lines add further corrosive duty. For water treatment, the 8H5B can meter concentrated disinfectant and caustic feeds that would pit ordinary alloys.
Because the meter also returns density, a plant can monitor acid concentration drift and detect a batch change without a second instrument. In hazardous zones, the Ex section lists versions with equipment protection level Gb, Zone 1 in the measuring tube, subject to the XA safety document.
How 8H5B differs from other Promass H variants
The H 100 and H 300 put electronics on the sensor; the 8H5B takes the transmitter off the pipe. Its accuracy of 0.10 % and its tube materials are shared with the family, but the remote design brings a choice of four transmitter housings, from a 1.4 kg polycarbonate digital unit to a 15.6 kg cast stainless one. Against the Promass E 500 (8E5B), which is dual-tube, mid-range and limited to 150 degC, the 8H5B reaches 205 degC with zirconium and stops at DN 50 instead of DN 80.
Flange options are narrower too: the 8H5B lists only fixed flange connections (EN 1092-1, ASME B16.5, JIS B2220), where hygienic sensors such as the I 500 add clamp and thread couplings.
Choosing a configuration for 8H5B
Decide the tube first. Zirconium 702 (order option DA) carries the higher temperature limit of 205 degC; tantalum 2.5W (option EA) is limited to 150 degC but is the datasheet basis for gas measurement at 0.50 %. Next select the diameter against the flow table, then the flange standard. The special density package EE narrows density error to 0.002 g/cm3 within 0 to 2 g/cm3 and +10 to +80 degC.
Finally choose transmitter housing and sensor connection housing. For a coastal plant with salt-laden air, the cast stainless transmitter (1.4409, similar to 316L) is the heavier but more resistant option.
Mounting and start-up of the 8H5B
Keep the sensor filled and free of gas pockets; the datasheet advises installing at a low point or downstream of a pump so static pressure prevents outgassing. Zero-point checks are most worthwhile at low flow or very high process temperature. Support heavy flanged pipework so the sensor does not carry pipe stress. Wire the remote cable with the manufacturer terminal assignment and ground per the instructions, then configure the current output and display through the touch screen.
Care and verification of 8H5B
Tantalum and zirconium tubes should never be exposed to fluids outside their approved chemical range, so keep a record of cleaning agents. Run Heartbeat Verification on a schedule and store the report. Inspect gaskets whenever the line is opened.
Documents and quotation
The datasheet attached to this page is Technical Information TI01283D. Send your RFQ to Seven Star LLC with part number 8H5B, the complete order code, nominal diameter, flange standard and quantity, and we will confirm availability.
Other Models in the Promass 500 Range
Seven Star LLC supplies models from the Promass 500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser 8I5B Promass I 500 Straight-Tube Coriolis Meter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 8E5B Promass E 500 Remote Coriolis Flowmeter | Ultrasonic Flowmeters | View details |
| Endress+Hauser 8H5B Promass H 500 Corrosion-Resistant Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser 8H5B Promass H 500 Corrosion-Resistant Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser 8H5B Promass H 500
Answers from our engineering team on installation, compatibility and integration.
01What is the measuring tube of the 8H5B made of?
Zirconium 702 (UNS R60702) or tantalum 2.5W, which gives the Promass H 500 its high resistance to aggressive chemicals.
02What is the maximum medium temperature for the 8H5B?
Up to 205 degC with zirconium (option DA) and up to 150 degC with tantalum (option EA), per TI01283D.
03Which line sizes does the 8H5B cover?
DN 8, 15, 25, 40 and 50, which equals 3/8 to 2 inch, with tantalum full scale from 2 000 to 70 000 kg/h.
04Is the 8H5B transmitter remote?
Yes. The 500 platform separates the transmitter from the sensor and provides up to four I/Os plus a backlit touch display with WLAN.
05How should I request the 8H5B?
Send an RFQ to Seven Star LLC with 8H5B, the full order code, tube material, flange standard and quantity.