Brand: ABB
ABB 1SBL297501R1300 AF38-22-00-13 4-Pole Contactor, 55 A AC-1
Description
ABB 1SBL297501R1300: the largest four-pole AF38 contactor in the 22 series
The AF38-22-00-13, order code 1SBL297501R1300, tops the four-pole 22 group in the AF38 frame. It has two normally open and two normally closed main poles and is described by ABB as a contactor for non-inductive and slightly inductive loads up to 690 V AC and 440 V DC. The headline number is the AC-1 current: 55 A at 40 degrees C, 45 A at 60 degrees C and 37 A at 70 degrees C, with a thermal current of 55 A on 16 mm2 conductors.
Everything a user touches is on the large side of the AF09-AF38 range. Main terminals are M4.5 screws torqued to 2.5 Nm, rigid and flexible conductors of 1.5 to 16 mm2 are accepted, and the UL general use rating is 55 A at 600 V AC on AWG 6 wire. The coil is the 100-250 V 50/60 Hz and DC type, with an electronic interface and built-in surge protection.
What the 1SBL297501R1300 brings to a heating panel
- 55 A AC-1 for resistive banks, with 63 A gG fuse protection up to 500 V.
- Four poles for simultaneous phase and neutral switching or for N.O./N.C. changeover.
- Short-time withstand of 450 A for 1 s.
- Power loss of 2.3 W per pole at full AC-1 current.
- Weight 0.360 kg.
1SBL297501R1300 technical table
| Order code | 1SBL297501R1300 |
|---|---|
| Type | AF38-22-00-13 |
| Main poles | 2 N.O. + 2 N.C. |
| Control voltage | 100-250 V AC 50/60 Hz and DC |
| Rated voltage Ue | 690 V |
| Thermal current Ith | 55 A, 16 mm2 |
| AC-1 at 40 / 60 / 70 C | 55 A / 45 A / 37 A |
| gG fuse up to 500 V | 63 A |
| Short-time current 1 s | 450 A |
| Loss per pole at AC-1 | 2.3 W |
| UL general use 600 V AC | 55 A (AWG 6) |
| Main screws | M4.5, 2.5 Nm |
| Conductor range | 1.5-16 mm2 |
| Stripping length | 12 mm |
| Impulse withstand | 6 kV |
| Altitude limit | 3000 m |
| Mechanical life | 10 million cycles |
| Weight | 0.360 kg |
Why choose AF38-22-00-13 instead of AF26-22 or AF16-40
The AF26-22 is the same size and shares its terminals; its AC-1 current is 45 A at 40 degrees C. AF38-22-00-13 raises the current to 55 A but increases the power loss per pole from 1.6 W to 2.3 W, which matters in a closed panel. The gG fuse increases from 50 A to 63 A. If your load needs the neutral switched with four N.O. poles, the four-pole N.O. contactors are the AF16-40 (30 A) and AF26-40 or AF38-40 versions; the 22 layout used here has two N.C. poles, so it is the right choice only when changeover action is needed.
Field applications
A 55 A resistive switching rating covers heater banks of about 38 kW at 400 V three-phase, which is typical for electric boilers, oil heaters and process air heaters in Omani industry. The N.C. poles suit duty and standby heaters, where one set is opened as the other is closed, and for discharge of loads on de-energisation. Check the loss in the panel: four poles at 2.3 W add roughly 9 W of heat at full current.
Notes on installation
Mounting on rail or screws is as for the other AF frames; the datasheet states that the contactors can be assembled side by side. Use ferrules on stranded conductors, tighten main terminals to 2.5 Nm and coil terminals to 1.2 Nm. The ambient limit without an overload relay is -40 to +70 degrees C and at 70 degrees C the AC-1 current falls to 37 A. The AF coil needs an average of 50 VA to pull in, and the drop-out voltage is 60 percent or less of the minimum coil voltage.
Electrical details that help the control designer: the coil holds with 2.2 VA or 2 W, the N.O. poles close 40 to 95 ms after the coil is energised and open 11 to 95 ms after it is released, and the maximum switching frequency at AC-1 is 600 cycles per hour. Terminals are delivered open and the screws of unused terminals must be tightened before the unit is put into service. The contactor can be operated at up to 3000 m, in climatic category B of IEC 60947-1, and the rated insulation voltage is 690 V (600 V for UL and CSA), so the unit can sit on the same panel as other 690 V equipment without a derating study.
Maintenance
Inspect the four poles for wear on each shutdown and compare operating time with the 40 to 95 ms pull-in range. Since this contactor often switches heaters under continuous load, thermal discoloration on terminals is the commonest fault: re-torque terminals after the first load cycle. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SBL297501R1300
What is the AC-1 rating of 1SBL297501R1300? 55 A at 40 degrees C, 45 A at 60 degrees C and 37 A at 70 degrees C.
How are the poles of 1SBL297501R1300 arranged? Two normally open and two normally closed main poles.
Which fuse protects 1SBL297501R1300? A gG fuse of 63 A for supply up to 500 V AC when used without an overload relay.
What wire size can I connect to 1SBL297501R1300? 1.5 to 16 mm2 rigid or flexible, stripped 12 mm, on M4.5 screws.
What UL rating does 1SBL297501R1300 have? A general use rating of 55 A at 600 V AC on AWG 6 wire.
Documents and quotation
The technical datasheet for 1SBL297501R1300 is provided on this page. Send an RFQ with part number 1SBL297501R1300, the quantity and the delivery location to receive a quotation.
Ordering Checklist for the ABB 1SBL297501R1300
Before you ask for a quotation for the ABB 1SBL297501R1300, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the contactors & overload relays already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Other Models in the Abb Af Range
Seven Star LLC supplies models from the Abb Af range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SBL237001R1311 AF26-30-11-13 Contactor 11 kW, 1 N.O. + 1 N.C. | Contactors & Overload Relays | View details |
| ABB 1SBL157001R1301 AF12-30-01-13 Contactor 5.5 kW, 1 N.C. Built-in | Contactors & Overload Relays | View details |
| ABB 1SBL137501R1300 AF09-22-00-13 4-Pole Contactor, 2 N.O. + 2 N.C. | Contactors & Overload Relays | View details |
| ABB 1SBL297501R1300 AF38-22-00-13 4-Pole Contactor, 55 A AC-1 | Contactors & Overload Relays | You are viewing this model |
| ABB 1SBL237501R1300 AF26-22-00-13 4-Pole Contactor, 45 A AC-1 | Contactors & Overload Relays | View details |
| ABB 1SBL177201R1300 AF16-40-00-13 4-Pole Contactor, 4 N.O., 30 A AC-1 | Contactors & Overload Relays | View details |
Datasheets & Documents
- Datasheet ABB 1SBL297501R1300 AF38-22-00-13 4-Pole Contactor, 55 A AC-1 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SBL297501R1300 AF38-22-00-13 4-Pole Contactor,
Answers from our engineering team on installation, compatibility and integration.
01What is the AC-1 rating of 1SBL297501R1300?
55 A at 40 degrees C, 45 A at 60 degrees C and 37 A at 70 degrees C.
02How are the poles of 1SBL297501R1300 arranged?
Two normally open and two normally closed main poles.
03Which fuse protects 1SBL297501R1300?
A gG fuse of 63 A for supply up to 500 V AC when used without an overload relay.
04What wire size can I connect to 1SBL297501R1300?
1.5 to 16 mm2 rigid or flexible, stripped 12 mm, on M4.5 screws.
05What UL rating does 1SBL297501R1300 have?
A general use rating of 55 A at 600 V AC on AWG 6 wire.