Brand:

Honeywell STG83L SmartLine STG800 Gauge Pressure Transmitter

Description

STG83L at a glance

Honeywell STG83L is the lowest-range L-suffix model in the STG800 SmartLine gauge pressure family. It covers minus 14.7 psi up to 50 psi (minus 1.01 to 3.44 bar), with a minimum span of just 0.5 psi (0.034 bar), and it is available with 4 to 20 mA, Honeywell DE, HART 7 or FOUNDATION Fieldbus electronics.

The datasheet puts the STG83L in the same table as the STG830, which shares its range, and describes both as high performance gauge transmitters. The datasheet treats the L-suffix models as the STG80L body style, with 316L stainless steel or Hastelloy C-276 wetted parts, a choice of male or female threaded connections and a weight of only 3.6 lb (1.6 kg) in aluminium housing, against 8.3 lb (3.8 kg) for the STG800. Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer.

STG83L highlights

  • Accuracy 0.0375 percent of span standard and 0.025 percent optional.
  • Reference turndown 16.6:1; accuracy knee C 3 psi (0.20 bar).
  • Total performance 0.071 percent of span at 10 psi, 5:1 turndown.
  • Overpressure limit 75 psi (5.25 bar).
  • Choice of HART, DE, FOUNDATION Fieldbus or analog electronics.

STG83L data table

Parameter Value
Model STG83L (STG800 SmartLine gauge pressure, L-suffix)
Upper / lower range limit 50 psi (3.44 bar) / -14.7 psi (-1.01 bar)
Minimum span 0.5 psi (0.034 bar)
Maximum turndown 100:1
Accuracy (standard / optional) 0.0375 / 0.025 percent of span
Stability (percent of URL per year, 15 years) Up to 0.010 for the STG800 family
Reference turndown (standard / high accuracy) 16.6:1 / 16.6:1
Accuracy knee C 3 psi (0.20 bar)
Temperature coefficients (D / E / F) 0.0325 / 0.030 / 0.006
Total performance example 0.071 percent of span at 10 psi
MAWP 50 psi (3.5 bar)
Overpressure limit 75 psi (5.25 bar)
Output / protocols 4 to 20 mA, Honeywell DE, HART 7 or FOUNDATION Fieldbus
Supply voltage HART: 10.8 to 42.4 VDC (load 0 to 1,440 ohms); DE: 15 to 49.3 VDC; FOUNDATION Fieldbus: 9.0 to 32.0 VDC
Response time As fast as 80 ms
Rated ambient / meter body temperature -40 to 85 degC / -40 to 110 degC (operative limit 125 degC)
Process connections (STG80L inline) 1/2-inch NPT female, 1/2-inch NPT male, 9/16-18 high-pressure cone and thread female, G1/2-B male, DIN 19213 (except STG89L)
Wetted parts (STG80L) 316L stainless steel or Hastelloy C-276 diaphragm and process head
Fill fluid Silicone 200, CTFE, NEOBEE M-20 or Silicone 704
Housing Polyester powder-coated low-copper aluminium, Type 4X / IP66 / IP67; stainless housing optional
Net weight (STG80L) 3.6 lb (1.6 kg) with aluminium housing
Additional features Plugged impulse line detection option; NAMUR NE-107 diagnostics (HART, FF); display languages EN, DE, FR, IT, ES, RU, UK, TR, CN, JP

How STG83L differs from other STG800 L-suffix variants

The STG83L differs from the STG830 in body style rather than range: both reach 50 psi, but the STG83L belongs to the STG80L style, its accuracy knee is 3 psi (0.20 bar) instead of 1.5 psi (0.10 bar) and its reference turndown is 16.6:1 instead of 33.3:1. The datasheet’s total performance at 10 psi is 0.071 percent for the STG83L and 0.059 percent for the STG830.

Within the L-suffix models the STG83L has the narrowest range, and the highest sensitivity: minimum span of 0.5 psi compared with 2.5 psi for the STG84L and 15 psi for the STG87L.

Model URL Min span Total performance example
STG83L 50 psi (3.44 bar) 0.5 psi (0.034 bar) 0.071% at 10 psi
STG84L 500 psi (34.47 bar) 2.5 psi (0.17 bar) 0.067% at 100 psi
STG88L 6000 psi (413.68 bar) 30 psi (2.06 bar) 0.081% at 1200 psi

Applications for STG83L in Oman and the GCC

Low-pressure compact transmitters are used on gas blankets, compressor suction lines, vacuum and low-pressure air systems and on skid-mounted instrument tubing where space is limited. In the Gulf they appear on packaged gas conditioning skids, water treatment dosing skids, and tank gas blanket control loops.

Because the STG83L accepts vacuum to minus 14.7 psi it also suits condenser and deaerator monitoring.

Selection and compatibility notes for STG83L

Select the L body when a small, light unit is wanted and the process connection is a male or female thread rather than a pair of process heads. Confirm the thread style against the process piping: NPT, G1/2-B, 9/16-18 cone and thread and DIN 19213 are listed. Check the electronics option against your control system: HART for most, FOUNDATION Fieldbus (9 to 32 VDC) for fieldbus segments, and DE for existing Honeywell systems.

Consider the plugged impulse line detection option if the transmitter is on a long tap.

Installing and configuring STG83L

Fit the process connection with an appropriate sealant, mount above or below the tap according to the medium, and rotate the housing in 90 degree steps if needed. Wire per the wiring drawing, using the polarity-insensitive terminals, and confirm start-up.

Zero the unit at atmosphere and check the display language, selected from ten available.

Maintenance and diagnostics

Verification interval is application dependent; the family datasheet describes 15-year stability up to 0.010 percent of URL per year. Use the NAMUR NE-107 diagnostics (HART, FOUNDATION Fieldbus) to schedule maintenance on actual condition.

Questions about STG83L

What range does the Honeywell STG83L have? It spans minus 14.7 psi to 50 psi (minus 1.01 to 3.44 bar) with a minimum span of 0.5 psi (0.034 bar).

What does the L suffix mean in STG83L? In the STG800 datasheet the L models are listed as the STG80L body style, with their own threaded connection options and a weight of 3.6 lb (1.6 kg) with aluminium housing.

What outputs does the STG83L support? 4 to 20 mA, Honeywell DE, HART 7 and FOUNDATION Fieldbus are listed communication options.

What accuracy does the STG83L offer? Standard accuracy is 0.0375 percent of span with 0.025 percent as the high-accuracy option.

What is the overpressure limit of the STG83L? The datasheet gives 75 psi (5.25 bar) as the overpressure limit.

Documents and quotation

The STG800 specification 34-ST-03-83 gives full details of the STG83L and is available on request.

To request a quotation for Honeywell STG83L, send part number, quantity, range, output protocol, connection and approval to Seven Star LLC.

Other Models in the STG800L Range

Seven Star LLC supplies models from the STG800L range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STG83L SmartLine STG800 Gauge Pressure TransmitterPressure TransmittersYou are viewing this model
Honeywell STG84L SmartLine STG800 Gauge Pressure TransmitterPressure TransmittersView details
Honeywell STG88L SmartLine STG800 Gauge Pressure TransmitterPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Honeywell STG83L SmartLine STG800 Gauge Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STG83L SmartLine STG800 Gauge Pressure

Answers from our engineering team on installation, compatibility and integration.

01What range does the Honeywell STG83L have?
It spans minus 14.7 psi to 50 psi (minus 1.01 to 3.44 bar) with a minimum span of 0.5 psi (0.034 bar).
02What does the L suffix mean in STG83L?
In the STG800 datasheet the L models are listed as the STG80L body style, with their own threaded connection options and a weight of 3.6 lb (1.6 kg) with aluminium housing.
03What outputs does the STG83L support?
4 to 20 mA, Honeywell DE, HART 7 and FOUNDATION Fieldbus are listed communication options.
04What accuracy does the STG83L offer?
Standard accuracy is 0.0375 percent of span with 0.025 percent as the high-accuracy option.
05What is the overpressure limit of the STG83L?
The datasheet gives 75 psi (5.25 bar) as the overpressure limit.