Endress+Hauser 40E Promass 40E Compact Coriolis Flowmeter

Description

40E at a glance

Among the Coriolis meters of Endress+Hauser, the 40E was the basic one. TI00055D presents the Proline Promass 40E as the flowmeter for minimized cost of ownership combined with a compact field transmitter, for highly accurate measurement of liquids and gases in standard applications. It has a compact dual-tube system, a medium temperature up to 140 degC, process pressure up to 100 bar, and a two-line backlit display without local operation. Only the compact version is offered.

Accuracy is stated as 0.50 percent of reading for liquids and 1.00 percent for gases, which is wide enough for utility and batching jobs and well below the 0.1 percent class of later devices. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We handle the 40E by order code.

40E properties

  • Dual-tube sensor in sizes DN 8 to DN 80
  • Medium temperature up to 140 degC and pressure up to 100 bar
  • Mass flow, density-independent measurement of liquids and gases
  • Sanitary and industrial process connection range, including VCO
  • Two-line backlit display, IEC, EN and NAMUR compliance

40E data table

Parameter Value for 40E
Product root 40E, Proline Promass 40E (TI00055D, edition 14.18)
Positioning Flowmeter for minimized cost of ownership with a compact field transmitter
Sensor design Compact dual-tube system, compact version only
Nominal diameters DN 8, 15, 25, 40, 50, 80 (3/8 to 3 inch)
Full scale DN 8 0 to 2 000 kg/h
Full scale DN 15 0 to 6 500 kg/h
Full scale DN 25 0 to 18 000 kg/h
Full scale DN 40 0 to 45 000 kg/h
Full scale DN 50 0 to 70 000 kg/h
Full scale DN 80 0 to 180 000 kg/h
Liquid flow accuracy 0.50 % of reading
Gas mass flow accuracy 1.00 % of reading
Repeatability Liquids 0.25 % of reading; gases 0.50 %
Temperature accuracy 0.5 degC plus 0.005 times T degC
Medium temperature Up to +140 degC (+284 degF)
Process pressure Up to 100 bar (1 450 psi)
Sensor housing Stainless steel 1.4301 (304), acid and alkali-resistant surface
Process connection material Stainless steel 1.4404 (F316/F316L)
Connections Flanges EN 1092-1, NE 132 Namur lengths, ASME B16.5, JIS B2220; VCO; Tri-Clamp; DIN 11851, SMS 1145, ISO 2853, DIN 11864-1 threads; DIN 11864-2 flange
Surface Not polished or Ra max 0.8 micrometer mechanically polished
Display Two-line backlit, without local operation
Supply 85 to 260 V AC; 20 to 55 V AC; 16 to 62 V DC
Ambient temperature -20 to +60 degC; optional -40 to +60 degC
Protection class IP67 (NEMA 4X)
Weight DN 8 / 15 / 25 8 / 8 / 10 kg
Weight DN 40 / 50 / 80 15 / 22 / 31 kg (PN 40 flanges)

Where the 40E is used in the Gulf

Compact Coriolis meters of this class are common on chemical dosing skids, fuel and lube transfer, boiler fuel and water-treatment additive lines. Basic standard applications dominate: transfer metering of oils and solvents, batch loading, steam-boiler chemical feed, and monitoring of compressed gas consumption. In sanitary versions with Tri-Clamp or DIN 11851 connections it can also meter syrups and juice concentrates.

How 40E differs from other Promass versions

The Promass 40E is accuracy-limited by design: liquid flow 0.50 percent of reading, against 0.15 percent for Promass E 500 (8E5B) at the same DN 8 to 80 sizing, and 0.10 percent for the Promass H 500 and I 500. It has no remote version and lists only HART on its cover page, whereas the Promass 83X offers HART, PROFIBUS PA/DP, Modbus RS485, FOUNDATION Fieldbus and EtherNet/IP. It shares with the later E-line (E 500) the six nominal diameters and the full scale figures of 2 000 to 180 000 kg per hour.

Specifying the 40E

Pick the diameter from the full-scale table, choose the surface (not polished or mechanically polished to Ra 0.8 micrometer) and the connection family. Flanges to NE 132 Namur lengths help replace older meters without piping changes. Choose supply voltage and ambient range option, then send the code to Seven Star LLC.

Installing 40E

No inlet or outlet runs are needed. Ensure that static pressure is high enough to prevent outgassing and cavitation, avoid mounting at the highest point of a vertical pipe, and respect the special installation instructions for the rupture disk where applicable. The ambient range of minus 20 to plus 60 degC applies to sensor and transmitter.

Maintenance of 40E

Verify zero at no flow after installation, check cable entries and keep the sensor free of build-up. If the display shows diagnostics, follow the error list in the operating manual.

A word on procurement. The 40E sits in the legacy part of the catalogue, so spare sensors and transmitters are usually requested by the root printed on the nameplate, together with the nominal diameter and the connection type. If the existing line used Namur-length flanges, say so, because the face-to-face length is then fixed by NE 132 and a replacement must respect it. The transmitter is a field housing in powder-coated die-cast aluminum with a glass or polycarbonate window, and the sensor housing is acid and alkali-resistant stainless steel 1.4301, which suits most industrial atmospheres in the Gulf.

Quick answers on 40E

The 40E weighs 8 kg at DN 8 and DN 15 up to 31 kg at DN 80. It is powered from 85 to 260 V AC, 20 to 55 V AC or 16 to 62 V DC. The current output is active or passive with a time constant from 0.05 to 100 seconds. Zero point stability is given per size in the datasheet.

Documents and quotation

Technical Information TI00055D is the datasheet for the 40E. Send an RFQ to Seven Star LLC with part number 40E, nominal diameter, connection and quantity.

Spares and Lifecycle Considerations

For critical service, many plants hold one Endress+Hauser 40E as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical ultrasonic flowmeters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Delivery to Sites in Oman and the GCC

Delivery of the Endress+Hauser 40E is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive ultrasonic flowmeters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser 40E Promass 40E Compact Coriolis Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser 40E Promass 40E Compact Coriolis

Answers from our engineering team on installation, compatibility and integration.

01What is the Promass 40E?
A compact dual-tube Coriolis flowmeter positioned for minimized cost of ownership, with a compact field transmitter and two-line backlit display.
02What sizes does the 40E offer?
DN 8, 15, 25, 40, 50 and 80 (3/8 to 3 inch), with liquid full scale from 2 000 to 180 000 kg/h.
03What are the temperature and pressure limits of the 40E?
Medium temperature up to plus 140 degC and process pressure up to 100 bar (1 450 psi) per the cover page.
04What accuracy does the 40E state?
Plus/minus 0.50 percent of reading for liquids and 1.00 percent for gases.
05How do I quote the 40E?
Send an RFQ to Seven Star LLC with 40E, nominal diameter, connection type and quantity.