Brand:

Danfoss 060-216466 KP 34 Boiler Pressure Switch

Description

Danfoss 060-216466: KP 34 low-pressure switch for boilers and heating plant

Danfoss 060-216466 is the boiler-version KP 34 with automatic reset. It is built for very low pressures: the setting range is 0.1 to 1.0 bar, the differential is adjustable from 0.1 to 0.4 bar, and the connection is a G 1/2 A thread rather than the G 1/4 A of the refrigeration-style KP 35. The product page lists boilers as the application and gives a net weight of 0.481 kg.

The KP 34 is relevant wherever low-pressure steam or hot-water systems need pressure control, such as small steam boilers, calorifiers and heating plants in hotels and hospitals. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Boiler-version construction

The datasheet groups the boiler versions with a stainless steel bellows and a nickel-plated free-cutting steel connector and states that they can handle steam, air, gaseous media and liquids. The larger G 1/2 A connection offers an easier, bulkier impulse pipe connection suited to a siphon loop.

The switch is a single-pole double-throw design with silver contacts and a snap action.

Technical specification for 060-216466

Parameter Value
Code number 060-216466
Type KP 34, boiler version
Reset Automatic
Setting range 0.1 to 1.0 bar
Differential 0.1 to 0.4 bar
Connection G 1/2 A
Max. working pressure 4 bar (product page)
Contacts SPDT silver
Contact rating 16 A resistive at 240 V single phase, 8 FLA 48 LRA at 240 V, 120 V 16 FLA 96 LRA, 3 A pilot duty (product page, UL basis)
Datasheet contact load AC-1 16 A 400 V, AC-3 16 A 400 V, AC-15 10 A 400 V, DC-13 12 W 220 V
Fluids Steam, air, gas, liquids
Enclosure IP30
Ambient -40 to 65 C
Net weight 0.481 kg
Approvals CE, CCC, EAC, RINA, UL 353 and UL 873
EAN 5702428365383

Where 060-216466 is used in Oman

Gulf hotels and hospitals operate steam boilers and hot-water generators for laundry and sterilisation, and food factories use low-pressure steam for cooking and cleaning. A pressure switch with a 0.1 to 1.0 bar window can restart a burner at a few hundred millibar, give a cut-out for a low-pressure steam header, or signal low water pressure in a closed heating loop.

As the setting is made on a scale the contractor can adjust in the field, and the differential is adjustable, the switch suits plant with different operating pressures.

How 060-216466 differs from other boiler-version KP switches

Parameter Value
060-216466 KP 34, 0.1 to 1.0 bar, differential 0.1 to 0.4 bar, automatic reset, test pressure 4.0 bar in datasheet
060-216366 KP 34, 0.1 to 1.0 bar, fixed differential 0.2 bar, manual reset
060-216666 KP 35, 0.4 to 3.4 bar, differential 0.4 to 2.2 bar, automatic reset, 10 bar test
060-215966 KP 36, 1.0 to 10.0 bar, automatic reset, 17 bar
060-216166 KP 37, 4.0 to 20.0 bar, automatic reset, 28 bar

This one is the lowest range in the boiler family, and it has its own housing drawing in the datasheet.

Selection and installation of 060-216466

Use a siphon so that live steam does not touch the bellows, and keep the temperature at the switch below the 100 C media limit given for these switches. Mount the unit upright on a wall bracket or flat plate, connect to the G 1/2 A port with a flat seal, and keep the impulse line short. The cable goes through a rubber gland for 6 to 14 mm cable.

Observe local boiler regulations: a pressure switch for control is not automatically a certified safety limiter.

Setting 060-216466

With automatic reset, set the cut-out on the range scale and the differential on the DIFF scale. The restart pressure for a high-pressure duty is cut-out minus differential. For example, a cut-out of 0.8 bar with a differential of 0.3 bar gives a restart at 0.5 bar. Always check with an accurate gauge.

Maintenance

Inspect the siphon and impulse line for scale, test the contact with the manual trip, and replace the switch if the scale and the gauge disagree. The unit is not repairable.

Ordering

State 060-216466 in full. Other KP 34 codes differ in reset function.

Electrical notes for 060-216466

The product page lists UL-style contact ratings: 16 A resistive single-phase at 240 V, 8 full-load amps and 48 locked-rotor amps at 240 V, and 16 full-load amps with 96 locked-rotor amps at 120 V with 3 A pilot duty. The datasheet gives IEC ratings for the boiler version. Insulation is 400 V with pollution degree 3 and a 4 kV impulse rating, and a 16 A fuse is recommended. Terminals accept 0.75 to 2.5 mm2 wire. The unit is approved to UL 353 and UL 873, and is CE, CCC, EAC and RINA marked, which helps when documenting marine or industrial installations.

Practical cautions with a 1 bar switch

At a setting window below 1 bar every piece of pipe geometry matters. A 3 m vertical impulse pipe filled with condensate adds about 0.3 bar of static head, which is as large as the whole differential of this switch, so mount the unit at the same level as the tapping or correct the setting for the height difference. Keep the impulse line free from air pockets and from dirt that could cause slow response.

Because the pressure is low, the switch also reacts to boiler pulsation during burner firing. If the contacts chatter, use a small restrictor or a siphon with a throttling needle valve. Record the final cut-out and restart pressures in the plant log so that later maintenance personnel can compare them with the original figures.

Documents and quotation

The datasheet covering the KP and KPI industrial range is attached. Send an RFQ with the part number and quantity.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Danfoss 060-216466 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Danfoss equipment can be planned around it.

Datasheets & Documents
  • PDF Datasheet Danfoss 060-216466 KP 34 Boiler Pressure Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-216466 KP 34 Boiler Pressure Switch

Answers from our engineering team on installation, compatibility and integration.

01What pressure range does Danfoss 060-216466 cover?
The KP 34 boiler version has a setting range of 0.1 to 1.0 bar and an adjustable differential of 0.1 to 0.4 bar.
02What is the connection thread of 060-216466?
G 1/2 A, which is larger than the G 1/4 A used by KP 35 and KP 36 refrigeration-type switches.
03Does 060-216466 reset automatically?
Yes, it is the automatic reset version; 060-216366 is the manual reset variant with a fixed 0.2 bar differential.
04What fluids may 060-216466 sense?
Steam, air, gaseous media and liquids, with stainless steel bellows and a nickel-plated steel connector.
05What is the maximum working pressure of 060-216466?
The Danfoss product page shows a maximum working pressure of 4 bar.