GESTRA NRG 16-51 High-Level Alarm Electrode PN 40
Description
GESTRA NRG 16-51 High-Level Alarm Electrode PN 40: overview
The GESTRA NRG 16-51 is the high-level alarm electrode in the NRG 1…-51 family. It works with the NRS 1-51 level switch to stop the water level from exceeding the preset maximum, for instance by switching off the feedwater supply before water can be carried over into the steam system.
When the level rises and the electrode rod enters the water, the NRS 1-51 raises the alarm. The switchpoint is set by the length of the electrode rod, so the correct length has to be specified with the order. As with the low-water electrode, the unit monitors itself and also alarms if the insulation is dirty or leaking or if the wiring has a fault.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the NRG 16-51 for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before asking for a quotation. The facts below are condensed from the manufacturer datasheet, and where a value is not stated there, we leave it out rather than guess.
Level and conductivity electrodes sit at the heart of every boiler protection and control loop. A boiler house runs for years between shutdowns, so the sensor is often one of the first parts to need replacement, and buyers usually need the exact type designation to be sure the new part fits the existing standpipe, thread and evaluation unit. Quote the full designation NRG 16-51 together with the nameplate data of the old unit, and we can check the details before a quotation is prepared.
Key features of the NRG 16-51
- Conductive measuring principle with self-monitoring of insulation and wiring
- PEEK electrode insulation on the PN 40 type
- Three standard lengths: 500, 1000 and 1500 mm
- Four-pole plug connector, or an F version with an aluminium terminal box for outdoor use
- G 3/4 A screw-in thread to ISO 228-1
- Can share a protection tube or external level pot with one GESTRA water level limiting electrode
GESTRA NRG 16-51 technical specifications
| Parameter | Value |
|---|---|
| Type | NRG 16-51 |
| Function | High-level alarm electrode, used with NRS 1-51 |
| Nominal pressure | PN 40 |
| Service pressure | 32 bar at 238 °C |
| Mechanical connection | Screwed G 3/4 A, ISO 228-1 |
| Screw-in body | 1.4571 (X6CrNiMoTi17-12-2) |
| Measuring electrode | 1.4571 |
| Electrode tip | 1.4401 (X5CrNiMo17-12-2) |
| Electrode insulation | PEEK |
| Lengths available | 500, 1000 and 1500 mm |
| Electrical connection | Four-pole plug connector (polyamide), cable gland M19 (PG 11) |
| Protection | IP 65 to EN 60529 |
| Max. ambient temperature | 70 °C |
| Weight | Approx. 1.2 kg without extension; approx. 2.1 kg for the F version |
All values above come from the manufacturer datasheet for the NRG 16-51 and its family. Related types named in the datasheet, such as NRG 17-51, NRG 19-51 and NRG 111-51, have their own ratings, so check the type designation before ordering.
Typical applications in Oman and the GCC
Process steam and hot water are everywhere in the region. Food and beverage plants, hospitals, hotels and laundries run package boilers; refineries, petrochemical sites and utility stations in Oman and the wider Gulf operate larger steam generators and thermal desalination units. In hot and dusty climates, cabinet temperature, cable routing and the condition of connectors deserve extra attention, and a spare unit on the shelf can shorten an outage considerably.
- Feedwater control chains in steam boiler plants where an independent maximum-level alarm is needed
- Boiler houses in district cooling, desalination and power utilities that must prevent water carry-over
- Pressurised hot-water systems that need a high-level alarm contact
- Refurbishment of older GESTRA level monitoring where the earlier electrode is no longer available
Selection and compatibility notes for the NRG 16-51
- Match the pressure class: the NRG 16-51 is PN 40. The NRG 17-51 is rated 46 bar at 260 °C, the NRG 19-51 100 bar at 311 °C and the NRG 111-51 183 bar at 357 °C.
- The high-level switchpoint is defined by the rod length, so specify it in millimetres.
- For outdoor use pick the F version with the aluminium terminal box.
- Combine it only with the NRS 1-51 level switch; the low-water duty belongs to the NRG 16-50 and NRS 1-50 pair.
If you are unsure which variant of the NRG 16-51 you have, photograph the nameplate and send the full text. The type, the pressure class or supply voltage and any suffix letters are what we need to match the right part.
Planning a spare is straightforward if you note a few details when the plant is down. Record the type designation, the installed length, the thread and the cable connection, and keep a photograph of the nameplate. Because the switchpoint or measuring range of an electrode depends on its rod length, a part of the right type but the wrong length will not behave like the part it replaces. For a critical boiler, many operators keep one spare electrode of each installed type and length, which makes a failed test during an inspection a short job instead of a long wait.
Installation and commissioning
- Install in a protection tube or external level pot with an inside diameter of 100 mm when sharing the space with a limiter electrode.
- Keep at least 40 mm from the upper vent hole when the electrode is fitted inside the vessel.
- Do not exceed 45 degrees of inclination, and limit the rod length to 1000 mm when inclined.
- With the 0.5 microsiemens setting on the NRS 1-51, use a measuring surface extension and a double-screened low-capacitance data cable up to 30 m.
- Not for use in potentially explosive atmospheres.
Always follow the manufacturer manual and the safety rules of your site and boiler inspection body during installation and commissioning. Isolate and depressurise the plant before any work on pressure-bearing parts and lock off the electrical supply before opening a terminal box or cabinet.
Maintenance and service
- Simulate a high-level alarm at the NRS 1-51 as part of the periodic function test.
- Inspect the plug connector and cable gland for moisture ingress at each outage.
- Clean deposits from the insulation section if the alarm behaviour changes.
Record each test of the NRG 16-51 in the plant log. A written history of tests and replacements helps the inspector, shortens fault finding and gives you a clear basis for deciding when a spare should be ordered.
Related products and ordering notes
Typical companions are the NRS 1-51 level switch and the NRG 16-50 low-water electrode. If an external level pot is used, ask about the SRL logic unit as well.
When you order a NRG 16-51, state the quantity, the full type designation and any option or length that applies, and tell us the plant tag or project if you have it. Lead times depend on stock and on the manufacturer, so please ask early for planned shutdowns.
Frequently asked questions
What is the NRG 16-51 used for? It is the electrode for a high-level alarm. With an NRS 1-51 it raises an alarm when the water level exceeds the maximum and can be used to switch off the feedwater supply.
What is the pressure rating of the NRG 16-51? It is the PN 40 type with a service pressure of 32 bar at 238 °C.
Which lengths are available? The datasheet lists 500, 1000 and 1500 mm.
What is the insulation material? The NRG 16-51 uses PEEK electrode insulation; the NRG 111-51 uses a special ceramic.
Can I use it outdoors? Yes, in the F version with an aluminium terminal box, which has an M20 cable gland.
Documents and quotation
The manufacturer datasheet for the NRG 16-51 is available from us on request and is attached to this listing where file size allows. To receive a quotation, send an RFQ with the part number NRG 16-51, the quantity and your delivery location in Oman or the GCC, and our team will reply with availability and lead time.
Datasheets & Documents
- Datasheet GESTRA NRG 16-51 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.
Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.
GESTRA company profile
| Established | 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907 |
|---|---|
| Ownership history | Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017 |
| Product families | Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature |
| Applications | Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants |
Milestones
- 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
- 1907: The company is renamed Gustav F. Gerdts KG.
- 1987: It becomes a stock corporation, GESTRA AG.
- 2002: Flowserve takes over GESTRA.
- 2017: GESTRA becomes part of the Spirax Sarco group.
GESTRA products we list
| Series | Type | What it does |
|---|---|---|
| UNA 45, UNA 16, UNA 38 | Ball float steam traps | Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100) |
| BK 45 | Bimetallic steam trap | Robust trap for steam main drainage and tracing, resistant to water hammer |
| MK 45, TK 23, SMK 22-81 | Thermostatic steam traps | Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam |
| MPA 46 | Rapid-action blowdown valve | Short, intermittent bottom blowdown that removes sludge from the boiler |
| NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 | Boiler level controls | Water level limiting, feedwater control and continuous level measurement |
| LRGT 16-1, LRR 1-50 | Conductivity measurement and control | Keeps boiler water conductivity in range through continuous blowdown |
| TRS 5-50 | Safety temperature limiter | SIL 3 temperature limiting for boilers and hot water systems |
The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.
Where GESTRA products are used
In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.
Ordering GESTRA parts: what we need
Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.
Facts checked against GESTRA company history and Bremen city records, October 2026.
Browse GESTRA products by category: Liquid Analysis Sensors.
FAQ
Questions about the GESTRA NRG 16-51 High-Level Alarm Electrode PN 40
Answers from our engineering team on installation, compatibility and integration.
01What is the NRG 16-51 used for?
It is the electrode for a high-level alarm. With an NRS 1-51 it raises an alarm when the water level exceeds the maximum and can be used to switch off the feedwater supply.
02What is the pressure rating of the NRG 16-51?
It is the PN 40 type with a service pressure of 32 bar at 238 °C.
03Which lengths are available?
The datasheet lists 500, 1000 and 1500 mm.
04What is the insulation material?
The NRG 16-51 uses PEEK electrode insulation; the NRG 111-51 uses a special ceramic.
05Can I use it outdoors?
Yes, in the F version with an aluminium terminal box, which has an M20 cable gland.