Brand:

AMETEK 7001-224-TE WDG-V Convection Loop Kit O2 Only

Description

AMETEK 7001-224-TE overview

AMETEK 7001-224-TE is the convection loop kit with nut and ferrules for the O2-only Thermox WDG-V analyzer. In the manual spare parts list it is described as the long tube version for use without flame arresters, while the companion kit 7001-225-TE is the short tube for use with flame arresters. The convection loop carries sample gas past the zirconia cell by thermal convection, and the correct tube length has to match the way the analyzer is configured, which is why the exact number matters when ordering.

The Thermox WDG-V is AMETEK Process Instruments’ close-coupled extractive analyzer for excess oxygen in flue gas. The datasheet describes a zirconium oxide sensor, measurement redundancy, continual diagnostic functions and SIL 2 capability for burner management systems, with flue gas temperatures up to 1648 degrees C (3000 degrees F) depending on the probe. It is completely field-serviceable, and the manual lists the spare parts by AMETEK part number.

Key features of 7001-224-TE

  • Convection loop with nut and ferrules for O2-only WDG-V analyzers
  • Long tube version, for use without flame arresters per the manual
  • Companion short tube kit is 7001-225-TE for use with flame arresters
  • Supplied with compression hardware for reassembly
  • Part of the sample path around the zirconia cell
  • Photo shows a bent stainless tube with fitting

7001-224-TE technical specifications

Item Detail
Part number 7001-224-TE
Description Kit, convection loop with nut and ferrules, O2 only
Tube length Long tube, for use without flame arresters (manual)
Short tube alternative 7001-225-TE, for use with flame arresters
Flame arrestor assembly 71212SE (manual spare parts list)
Used in Thermox WDG-V O2-only analyzers
Principle (datasheet) Zirconium oxide for excess oxygen
Output range 0-1 percent to 0-100 percent O2
Accuracy Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent, whichever is greater
Response 90 percent of a step change in under 11 seconds with flame arrestors
Aspirator air About 3 SCFH at 3 to 6 psig, instrument air or nitrogen
Outputs Three isolated linear current outputs, five alarms, Modbus RTU, HART option
Enclosure Hinged IP65 (NEMA 4X) stainless steel
Power 115 VAC or 230 VAC, plus or minus 10 percent, 740 VA maximum

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7001-224-TE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

Process heaters, steam boilers and thermal oxidizers are the applications named in the datasheet, and the key markets are refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and across the GCC those applications correspond to refinery heaters, gas processing furnaces, utility boilers and thermal oxidizers on petrochemical and fertilizer sites, where excess oxygen is the primary indicator for burner efficiency and safe combustion.

Where 7001-224-TE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 7001-224-TE

Confirm the analyzer version (O2 only, combustibles, or combustibles and methane), the supply voltage of the unit and, if possible, the AMETEK serial number before ordering. The WDG-V manual spare parts table is the reference that ties each number to a version.

Part number 7001-224-TE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Isolate the process and let the analyzer cool, then release the compression fittings at both ends of the existing convection loop. Fit the new loop with the nut and ferrules supplied in 7001-224-TE, tightening carefully so that the ferrules seat and seal. Check that the choice of tube length agrees with the flame arrestor configuration of the analyzer, because the manual distinguishes the long tube for use without flame arresters from the short tube for use with them. Leak check, reopen the process valves and verify the oxygen reading with a calibration check.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7001-224-TE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

Inspect the loop for corrosion or plugging when the analyzer shows a slow response. The WDG-V datasheet quotes oxygen response of 90 percent of a step change in under 11 seconds with flame arrestors, so a drift in response time is a useful maintenance trigger.

Related products and ordering notes

Review 7001-225-TE, flame arrestor assembly 71212SE and the aspirator kit 7001-216-TE together with 7001-224-TE.

For a spare parts plan, list 7001-224-TE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Operators in Oman and the Gulf work in high ambient temperatures, dust and humidity, and sites often plan turnarounds months ahead, so confirming the exact number of every spare before the shutdown window is valuable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle enquiries for hard-to-find and legacy numbers directly.

Frequently asked questions about 7001-224-TE

  • What is AMETEK 7001-224-TE? It is the convection loop kit with nut and ferrules for the O2-only Thermox WDG-V analyzer, in the long tube version.
  • When is the long tube used? The WDG-V manual describes 7001-224-TE as the long tube for use without flame arresters.
  • What is the short tube kit? The manual lists 7001-225-TE as the flame arrester convection loop, a short tube for use with flame arresters.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7001-224-TE, send the RFQ with the part number 7001-224-TE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK WDG-V Flue Gas Oxygen Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 7001-224-TE WDG-V Convection Loop Kit O2 Only

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 7001-224-TE?
It is the convection loop kit with nut and ferrules for the O2-only Thermox WDG-V analyzer, in the long tube version.
02When is the long tube used?
The WDG-V manual describes 7001-224-TE as the long tube for use without flame arresters.
03What is the short tube kit?
The manual lists 7001-225-TE as the flame arrester convection loop, a short tube for use with flame arresters.
04Is 7001-224-TE for combustibles units?
The AMETEK listing says O2 only, so combustibles and methane units use other block and loop hardware.
05How do I request a quotation for 7001-224-TE?
Send the part number 7001-224-TE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.