Brand: Gent
Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Fire Alarm Panel
Description
VIGPLUS-24: Gent Vigilon Plus addressable fire alarm control panel, 1 to 4 loops
The Gent VIGPLUS-24 is a Vigilon Plus analogue addressable fire alarm control panel supplied with one loop card and an integral printer. It is expandable to four detection loops, is designed to EN 54 parts 2 and 4, and forms the core of a fire detection system for buildings and industrial sites.
Within the Gent range the code identifies the 1 to 4 loop panel with one loop card and printer; the sister code VIGPLUS-24-NP is the same panel without a printer, and VIGPLUS-72 is the larger 1 to 6 loop panel with a 72-hour standby option. Seven Star LLC supplies the VIGPLUS-24 in Oman and the GCC as an independent supplier in Muscat.
VIGPLUS-24 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Gent (Honeywell) / VIGPLUS-24 |
| Type | Analogue addressable fire alarm control panel |
| Loops | 1 loop card supplied; expandable to 4 loops (additional card VIG-LPC-EN) |
| Standards | EN 54 parts 2 and 4 |
| Devices per loop | Up to 200 addressable devices |
| Loop cable length | Up to 2 km of approved fire-rated cable; up to 2.5 km with 2.5 mm² |
| Display | 40 characters x 8 lines, back-lit |
| Printer | 40-character thermal printer (integral, on this variant) |
| Keypad | Internal, full QWERTY keyboard |
| Zonal indicators | 32 “secret until lit” zone indicators |
| Sounder circuits | 2 x 400 mA, 24 V, monitored |
| Auxiliary outputs | 2 x DPCO volt-free programmable contacts; 1 x SPCO manned centre link |
| Serial port | RS232/RS485 (additional card needed) |
| Networking | RS485 network card; up to 31 panels per domain, up to 200 panels on a multi-domain network |
| Addressing | SAFE or soft addressing |
| Memory | Flash memory card for commissioning and extended event log |
| Standby | Integral charger and monitored sealed lead-acid cells for 24 hours plus 30 minutes in alarm |
| Mounting | Surface, or flush with the VIG-24-Flush surround |
How the VIGPLUS-24 works
Each detector on the loop sends analogue values to the panel in digital form. The panel monitors the background conditions every 80 seconds and, when a sensor reaches a threshold, takes 256 data readings, using fast scanning to locate threshold outstations within 0.5 seconds. Addresses are set by the panel (soft addressed) rather than by switches on the devices.
Short or open circuit faults on the loop are isolated by isolators in the devices, so the rest of the loop keeps working. Features such as co-incidence and multi-level detection, programmable output delays, timers to switch sensor states, and 255 non-fire programmable commands support site-specific cause-and-effect logic.
System fit and related Vigilon parts
A VIGPLUS-24 panel can be extended with additional loop cards VIG-LPC-EN, a copper network card VIG-NC or a fibre card VIG-NC-FO, and the VIG-IOC-DOM card for external communications. Field devices include S-Quad optical, heat and multi-sensor detectors, beam detectors, manual call points, sounders, visual alarm devices and loop-powered interface units. Fully functional loop repeater panels and mimic panels can be added on each loop.
For compact installations the 1 to 2 loop Compact Plus is the smaller panel, while the VIGPLUS-72 extends the platform to six loops and 72-hour standby.
Loop capacity planning with the VIGPLUS-24
Each loop can carry up to 200 addressable devices, including up to 200 loop-powered sounders, 100 visual alarm devices and 125 sensors with integral sounder, subject to loop loading. Up to 16 beam sensor pairs, 170 four-channel interfaces and four mimic or repeat panels can sit on one loop. Because the number of mixed devices is limited by loop current, the design should be checked with the manufacturer’s loop calculator before the cable route is fixed.
Spreading devices across loops by building zone or floor makes faults easier to isolate, and leaving spare capacity of 10 to 20 percent on every loop keeps future extension simple.
Selection and ordering checklist
- Number of loops and devices now and in the future (limit 4 loops on this panel).
- Printer required (VIGPLUS-24) or not (VIGPLUS-24-NP).
- Networking: copper or fibre network cards, number of panels.
- Standby battery duration against the project specification.
- Repeater, mimic and interface requirements.
- Surface or flush mounting.
Installation, commissioning and maintenance
Mount the cabinet on a firm wall at a suitable height with clear access, wire the mains supply through a dedicated fused spur, and connect the standby batteries last. Install loop cabling to the manufacturer’s recommendations, test insulation and loop resistance, then allocate addresses from the panel or commissioning software. The flash memory card supports commissioning and extended event log storage.
Maintenance follows the local fire code: periodic detector tests, battery checks (the panel reports charger or battery faults individually), cleaning of sensors in dusty environments and review of the event log.
Typical applications in Oman and the GCC
Addressable panels of this class are used in commercial towers, hospitals, hotels, airports, schools, warehouses, industrial plants and utility buildings. In dusty or hot conditions, select detectors and bases suitable for the environment, and allow for the effect of high ambient temperature on batteries; local civil defence approvals and project specifications decide the final configuration.
Vigilon Plus panel family
| Code | Description |
|---|---|
| Code | Description |
| VIGPLUS-24 | 1 to 4 loop panel with 1 loop card and printer |
| VIGPLUS-24-NP | 1 to 4 loop panel with 1 loop card, no printer |
| VIGPLUS-72 | 1 to 6 loop panel with printer and 72-hour standby option |
| COMPACTPLUS-24 | 1 to 2 loop compact panel |
Information to send with an RFQ
- Part number VIGPLUS-24 and quantity.
- Loop count, device list and network design.
- Add-on cards, batteries and flush surrounds.
- Approvals required by the project.
- Delivery location and schedule.
Related Gent products: Gent VIGPLUS-72 Vigilon Plus 6-Loop Fire Alarm Control Panel, Gent Vigilon Compact Plus 1-2 Loop Fire Alarm Control Panel, Gent VIG-LPC-EN Vigilon Loop Card, Gent S4-34420 Vigilon Loop Powered Interface Range, Gent NANO-24 Nano Single Loop Addressable Fire Alarm Panel (Legacy) and Gent COMPACT-RPT Vigilon LCD Repeat Indicator Panel.
Documents and quotation
Send us the part number VIGPLUS-24 and we will confirm available documents and stock status. Seven Star LLC is an independent supplier serving Oman and the GCC.
Datasheets & Documents
- manual Gent Vigilon Plus 4/6 Loop Control Panel Installation Instructions Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Gent is a British fire detection and alarm brand that traces its history to 1872, when John Thomas Gent started his business in Leicester. Gents' of Leicester made electric bells, signalling equipment and, for more than a century, electric clocks for public buildings and railway stations, before turning to fire and life safety systems. Gent has been part of Honeywell since 2005 and is still based in Leicester.
Seven Star LLC supplies Gent fire alarm panels and system parts to contractors and facility teams in Oman, including Vigilon control panels and loop cards for existing sites.
Gent company profile
| Founded | 1872, Leicester, England, by John Thomas Gent |
|---|---|
| Headquarters | Leicester, United Kingdom |
| Ownership | Honeywell, since 2005 |
| Early products | Electric and pneumatic bells, signals and electric clocks; air raid sirens during the Second World War |
| Product families | Vigilon and Compact addressable fire panels, S-Quad and S4 multi-sensor detectors, voice sounders and beacons, manual call points, interfaces and networking |
Milestones
- 1872: John Thomas Gent starts the company in Leicester.
- 1939: Gents' is commissioned to produce air raid sirens.
- 1981: Chloride takes over the company.
- 1982: It is sold to the MK Electric Group.
- 1993: Caradon (later Novar) acquires Gent.
- 2005: Honeywell takes over Gent.
- 2023: Honeywell Gent marks 150 years.
Gent Vigilon panels and parts listed here
Three of the items on this page are panel parts. The Vigilon Compact Plus is the smaller panel for one or two loops. The Vigilon Plus, listed as VIGPLUS-72, is the larger control panel for one to six loops with 72-hour standby capacity. The VIG-LPC-EN loop card adds or replaces a loop circuit in the VIGPLUS-24 and VIGPLUS-72 panels. On the loops, Gent uses its own device families, notably S-Quad devices that combine multi-sensor detection with sounder, voice and visual alarm options.
Gent products we list
Ordering Gent fire alarm parts: what we need
Gent systems are configured per site, so details matter. Send the part number from the panel or card label, the panel type and number of loops, the panel firmware version if shown, and the device types on the loop. For a new panel, state loops required, network cards, printer or repeater options and battery size. We supply to projects in the GCC and check each part number against the manufacturer's documentation.
Facts checked against Honeywell's Gent 150-year press release and the Science Museum Group archive, October 2026.
Browse Gent products by category: Logic Controller.
FAQ
Questions about the Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Fire Alarm
Answers from our engineering team on installation, compatibility and integration.
01How many loops does the VIGPLUS-24 support?
It ships with one loop card and can be expanded to four loops.
02How many devices fit on one loop?
Up to 200 addressable devices per loop.
03Does it include a printer?
Yes, the VIGPLUS-24 includes an integral 40-character thermal printer; the VIGPLUS-24-NP does not.
04Can panels be networked?
Yes, with network cards up to 31 panels per domain and up to 200 on a multi-domain network.
05Which standard does it follow?
The manufacturer lists EN 54 parts 2 and 4.