VEGA VEGACAP 98 Polypropylene Capacitive Rod Level Switch
Description
An economical all-plastic rod switch for unpressurised tanks
The VEGACAP 98 is VEGA’s adjustment-free, economical capacitive level switch for liquids and bulk solids, and the specification sheet singles out overfill protection and dry-run protection in adhesive, conductive products as the typical jobs. Its wetted parts are made completely of PP (polypropylene), the rod is up to 2 m long and the switch works in products from a dielectric constant of 1.5. Because it is limited to unpressurised operation and -40 to +80 °C, it is aimed at plain storage and day tanks, chemical dosing vessels and sumps rather than hot or pressurised process vessels.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | VEGACAP 98, capacitive rod electrode for level detection, relay (DPDT) |
| Sensor length | Up to 2 m (6.562 ft) |
| Process fitting | Thread G1½, 1½ NPT |
| Process pressure | Unpressurised operation |
| Process temperature | -40…+80 °C (-40…+176 °F) |
| Ambient, storage, transport | -40…+80 °C (-40…+176 °F) |
| Operating voltage | 20…253 V AC 50/60 Hz; 20…72 V DC |
| Power consumption | 1…8 VA (AC); approx. 1.5 W (DC) |
| Switching voltage / current | Min. 10 mV, max. 253 V AC/DC; min. 10 µA, max. 3 A AC, 1 A DC |
| Breaking capacity | Min. 50 mW; max. 750 VA AC, 54 W DC |
| Switching delay | 0.7 s (on/off) |
| Wetted parts | Completely PP |
| Housing | Plastic or aluminium, up to IP67 |
| Approval (as printed) | Overfill protection system acc. to Water Resources Act (WRA) |
Why an all-polypropylene rod
With no metal and no coating, the wetted surface is one material, which removes the question of whether a PTFE film or a stainless rod is compatible with a particular acid, alkali or cleaning chemical. The trade-off is range: the rod is shorter than in the metal-cored VEGACAP 62 or 64 and the rating stops at unpressurised service and +80 °C. VEGA presents the exact switching point under strong buildup and the low maintenance of the mechanical construction as the user benefits.
Setup, wiring and ordering
No filling of the vessel is needed to commission it. On the electronics module a DIL switch sets the mode (min or max) and a potentiometer sets the switching point, while a lamp shows the state. The relay has two changeover contacts, so one contact can feed a pump or valve and the other an alarm or PLC input, within the 3 A AC or 1 A DC limits printed in the sheet. A broad supply range of 20 to 253 V AC or 20 to 72 V DC lets the same module run in 24 V DC panels and on 230 V AC mains.
For an RFQ give the rod length, thread, medium and its dielectric constant, supply voltage and housing material. VEGA’s sheet refers to its online configurator for the full list of materials, seals and approvals, so please confirm those details, and whether the WRA approval applies to your exact version, with the manufacturer before ordering.
Related VEGA products: VEGA VEGACAP 64 PTFE Insulated Capacitive Rod Level Switch, VEGA VEGACAP 62 Capacitive Rod Point Level Switch up to 6 m, VEGA VEGACAL 63 Capacitive Rod Level Probe, VEGA VEGAPOINT 21 Compact Capacitive Point Level Switch, VEGA VEGACAP 65 Capacitive Cable Level Switch up to 32 m and VEGA VEGAPOINT 31 Capacitive Level Switch for Powders.
Documents and quotation
The official VEGA VEGACAP 98 (relay DPDT) specification sheet (34674-EN, version 160112) is attached to this page for download and covers the technical data, dimensions and wiring summarised above.
RFQs are welcome with the tag number, medium, process conditions and electrical requirements. Seven Star LLC is an independent supplier based in Muscat and will answer with a quotation; compare alternatives in our level instrumentation section. Ordering details such as configuration, approvals and connection should be confirmed with the manufacturer before purchase.
Datasheets & Documents
- Datasheet VEGA VEGACAP 98 Specification Sheet (34674-EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.
Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.
VEGA at a glance
| Origin | Founded by Bruno Grieshaber in 1959 in Triberg, Germany |
|---|---|
| Headquarters | Schiltach, Black Forest, Germany (since 1975) |
| Ownership | Family-owned company: VEGA Grieshaber KG |
| Milestones | First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids |
| Product families | VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning |
VEGA sensor and instrument series
| Series | Type | Typical use |
|---|---|---|
| VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 | Process radar level transmitters (80 GHz) | Storage and process tanks, reactors with agitators, silos and bulk solids |
| VEGAPULS 11, 21, 31, 42 | Compact radar sensors | Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration |
| VEGAPULS C 21, C 11, C 22, C 23 | Radar sensors with fixed cable, IP68 | Wet wells, pumping stations, open channels and river levels |
| VEGAFLEX 81, 82, 83, 86 | Guided wave radar (TDR) | Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86) |
| VEGASWING 61, 63, VEGAPOINT 21 | Vibrating and capacitive point level switches | Overfill protection, dry-run protection and high or low level alarms |
| VEGACAL 62 to VEGACAL 67 | Capacitive rod and cable probes | Point and continuous level in solids and conductive or adhesive liquids |
| VEGABAR 82, 83, 28, 29, 38 | Pressure transmitters, ceramic or metallic cell | Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities |
| VEGADIF 85 | Differential pressure transmitter | DP flow, filter monitoring and level in pressurised vessels |
| VEGAMET 841, VEGADIS 176 | Controller and loop display | Level display, pump control and remote indication of 4-20 mA signals |
Where VEGA instruments are used
VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.
Ordering VEGA instruments: what we need
The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.
Facts checked against VEGA company and product information, October 2026.
Browse VEGA products by category: Level Transmitter, Pressure Instrumentation, Controllers and Data Acquisition.
FAQ
Questions about the VEGA VEGACAP 98 Polypropylene Capacitive Rod Level
Answers from our engineering team on installation, compatibility and integration.
01What does the VEGACAP 98 do?
It is a capacitive point level switch for liquids and bulk solids, used for overfill and dry-run protection.
02What are its wetted materials?
Completely PP, according to the specification sheet.
03What are the process limits?
Unpressurised operation and -40…+80 °C.
04Which supply and output does it use?
20…253 V AC or 20…72 V DC with a DPDT relay output.
05What approval is mentioned?
Overfill protection system acc. to the Water Resources Act (WRA).