Brand:

SICK MLG10A-0740B10801 MLG-2 Measuring Light Grid

Description

MLG10A-0740B10801, part no. 1221116, belongs to the SICK MLG-2 range of measuring automation light grids for object and profile detection. The catalogue summary lists: device version: Pro – Extended functionality; inputs/outputs: 2 x analog + 2 x Q (IO-Link); option: None; beam separation: 10 mm; operating range: 8.5 m.

Understanding the MLG10A-0740B10801 before you specify it

It watches the shadow of an object across many beams, so one device gives height, position or the number of objects passing through. The data sheet gives the beam separation, operating range, detection height and response time.

These determine the smallest object that can be resolved and how fast the line may run. It is described in the operating instructions. Many closely spaced beams give a profile of height or position, while a few beams only indicate presence.

Technical specifications

Parameter Specification
Type code MLG10A-0740B10801
Part number 1221116
Product family MLG-2
Device version Pro – Extended functionality
Sensor principle Sender/receiver
Minimum detectable object (MDO) 10 mm; 14 mm;
Beam separation 10 mm
Type of synchronization Cable
Number of beams 75
Detection height 740 mm
Software features (default): QA1 Number of broken beams/NBB
Software features (default): QA2 Height measurement (last beam)/LBB
Software features (default): Q1 Presence detection
Software features (default): Q2 / IN Teach input
Software features (default): Teach Standard mode
Operating mode: Standard Yes
Operating mode: Transparent Yes
Operating mode: Dust- and sunlight-resistant Yes
Function: Cross beam Yes
Function: Beam blanking Yes
Function: High-speed scan Yes
Function: High measurement accuracy Yes
Applications: Switching output Object detection/object width; Object recognition; Height classification; Hole detection/hole size; Outside/inside dimension; Object position; Hole position; Zone definition
Included with delivery 1 × sender; 1 × receiver
Part number of individual components 2101919 MLGT10A-0740F10201, 2079532 MLGR10A-0740B10201
Light source LED, Infrared light
Supply voltage Vs DC 19.2 V … 28.8 V
Power consumption sender 58.75 mA
Power consumption receiver 135 mA
Output current Imax. 100 mA
Declarations and certificates in the data sheet EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; Moroccan declaration of conformity; China RoHS; cULus certificate; IO-Link certificate; Photobiological safety (IEC EN 62471)

Type code MLG10A-0740B10801 and what to check before ordering

For the control cabinet and the cable run, the relevant figures are response time of 7.1 ms; power draw of 58.75 mA; supply of DC 19.2 V … 28.8 V; current of 100 mA.

For the mounting location, note housing Aluminum; weight 1.749 kg; light source LED, Infrared light; operating temperature –30 °C … +55 °C; enclosure rating IP65, IP67;; vibration sinusoidal oscillation 10-150 Hz 5 g; wavelength 850 nm.

For installation, align sender and receiver parallel, protect the optics from dust and condensation and avoid reflective background surfaces.

Check the output and measuring modes against the controller before ordering.

Documents and quotation

You can download the SICK data sheet for MLG10A-0740B10801 (part no. 1221116) from this page. Send the type code, quantity and delivery location through the RFQ form and Seven Star LLC, an independent supplier in Muscat, will respond with a quotation. Similar products sit under Sensors & Transmitters. Confirm the full code against the device it replaces; if this page and the data sheet ever disagree, follow the data sheet.

Datasheets & Documents
  • PDF Data Sheet SICK MLG10A-0740B10801 official data sheet (part no. 1221116) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Facts checked against SICK's published company history and annual figures, October 2026.

Frequently Asked Questions

What is the SICK MLG10A-0740B10801?
It is a SICK measuring light grid (MLG-2), part no. 1221116. The catalogue summary reads: Device version: Pro - Extended functionality; Inputs/outputs: 2 x analog + 2 x Q (IO-Link); Option: None; Beam separation: 10 mm.
Which supply voltage applies to the MLG10A-0740B10801?
Supply voltage is DC 19.2 V ... 28.8 V. Check the output and interface rows in the table for the signal levels.
What protection rating and temperature range are given?
Enclosure rating: IP65, IP67;. Ambient operating temperature: –30 °C ... +55 °C. Confirm both against the site before ordering.
Does the page include the data sheet?
Yes. The official SICK data sheet for part no. 1221116 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
What should be confirmed before ordering the MLG10A-0740B10801?
Compare the full type code and part number 1221116 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.