SICK WTB16P-24162120A00 W16 Background Suppression Sensor
Description
WTB16P-24162120A00 is a SICK W16 photoelectric proximity sensor (part no. 1220916) that detects objects up to a set distance and ignores whatever lies behind that distance. The catalogue summary lists: sensing range min. / max.: 10 mm / 1,000 mm; functional principle: Photoelectric proximity sensor; functional principle detail: Background suppression; switching output: Push-pull: PNP/NPN; switching mode: Light/dark switching.
WTB16P-24162120A00: function, principle and typical use
Plain diffuse sensors depend on how much light an object reflects, so a white box and a black rubber part at the same distance give very different signals. The sensor needs a clear optical path.
Dust, oil mist and condensation on the front screen reduce the received signal over time, and sensors mounted at an angle to shiny surfaces can pick up unwanted reflections, so a slightly tilted mounting is common practice. Light switching and dark switching refer to whether the output is active when an object is present or absent.
Technical specifications
| Parameter | Specification |
|---|---|
| Type code | WTB16P-24162120A00 |
| Part number | 1220916 |
| Product family | W16 |
| Functional principle | Photoelectric proximity sensor |
| Functional principle detail | Background suppression |
| Sensing range: Sensing range min. | 10 mm |
| Sensing range: Sensing range max. | 1,000 mm |
| Sensing range: Adjustable switching threshold for background suppression | 100 mm … 1,000 mm |
| Sensing range: Reference object | Object with 90% remission factor (complies with standard white according to DIN 5033) |
| Sensing range: Minimum distance between set sensing range and background (black 6% / white 90%) | 25 mm, at a distance of 400 mm |
| Sensing range: Recommended sensing range for the best performance | 100 mm … 400 mm |
| Emitted beam: Light source | PinPoint LED |
| Emitted beam: Type of light | Visible red light |
| Emitted beam: Shape of light spot | Point-shaped |
| Emitted beam: Light spot size (distance) | Ø 6 mm (500 mm) |
| Emitted beam: Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) | < +/- 1.0° (at TU = +23 °C) |
| Key LED figures: Normative reference | EN 62471:2008-09 | IEC 62471:2006, modified |
| Key LED figures: LED risk group marking | Free group |
| Key LED figures: Wave length | 635 nm |
| Key LED figures: Average service life | 100,000 h at Ta = +25 °C |
| Adjustment: Teach-Turn adjustment | BluePilot; For setting the sensing range |
| Adjustment: IO-Link | For configuring the sensor parameters and Smart Task functions |
| MTTFD | 626 years |
| DCavg | 0% |
| IO-Link | ✔ , IO-Link V1.1 |
| Data transmission rate | COM2 (38,4 kBaud) |
| Process data length | 16 Bit |
| Process data structure | Bit 0 = switching signal QL1 |
| VendorID | 26 |
| DeviceID HEX | 0x80015C |
| Declarations and certificates in the data sheet | EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; Moroccan declaration of conformity; China RoHS; China Compulsory Product Certification (CCC) exempt; ECOLAB certificate; cULus certificate; IO-Link certificate; Photobiological safety (DIN EN 62471) certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854) |
Type code WTB16P-24162120A00 and what to check before ordering
For the control cabinet and the cable run, the relevant figures are current of ≤ 30 mA, without load. At UB = 24 V; supply of 10 V DC … 30 V DC; response time of ≤ 500 µs; range of 10 mm; frequency of 1,000 Hz.
For the mounting location, note wavelength 635 nm; weight approx. 50 g; operating temperature –40 °C … +60 °C; enclosure rating IP66 (EN 60529); IP67 (EN 60529); IP69 (EN 60529); light source pinPoint LED; dimensions 20 mm x 55.7 mm x 42 mm.
Before ordering, confirm the sensing range and the adjustable switching distance, the light type (visible red LED or laser), the output type (PNP or NPN or push-pull), the connection (cable or connector and its pin count) and the housing size.
A single character in the type code can change polarity or connector.
Documents and quotation
The official SICK data sheet for WTB16P-24162120A00 (part no. 1220916) is attached as a PDF. Send the type code, quantity and delivery location through the RFQ form and Seven Star LLC, an independent supplier in Muscat, will respond with a quotation. Similar products sit under Sensors & Transmitters. Confirm the full code against the device it replaces; if this page and the data sheet ever disagree, follow the data sheet.
Datasheets & Documents
- Datasheet SICK WTB16P-24162120A00 official data sheet (part no. 1220916) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
Related products
Frequently Asked Questions
It is a SICK background suppression sensor (W16), part no. 1220916. The catalogue summary reads: Sensing range min. / max.: 10 mm / 1,000 mm; Functional principle: Photoelectric proximity sensor; Functional principle detail: Background suppression; Switching output: Push-pull: PNP/NPN.
Supply voltage is 10 V DC ... 30 V DC. Check the output and interface rows in the table for the signal levels.
Enclosure rating: IP66 (EN 60529); IP67 (EN 60529); IP69 (EN 60529). Ambient operating temperature: –40 °C ... +60 °C. Confirm both against the site before ordering.
Yes. The official SICK data sheet for part no. 1220916 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
Compare the full type code and part number 1220916 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.