Brand:

SICK WTB4FP-22161100A00 W4 Background Suppression Sensor

Description

WTB4FP-22161100A00, part no. 1124609, is a SICK W4 background suppression sensor that switches on objects inside its sensing range regardless of the colour of the surface behind them. The catalogue summary lists: sensing range min. / max.: 4 mm / 220 mm; functional principle: Photoelectric proximity sensor; functional principle detail: Background suppression; switching output: Push-pull: PNP/NPN; switching mode: Light/dark switching.

Understanding the WTB4FP-22161100A00 before you specify it

A background suppression sensor works by triangulation: the light spot is received by two receiver elements, and the ratio of their signals tells the sensor how far away the object is. Darker or shinier objects change the usable range and the distance needed between object and background, so test with your real product before fixing the setting.

Dust, oil mist and condensation on the front screen reduce the received signal over time, and sensors mounted at an angle to shiny surfaces can pick up unwanted reflections, so a slightly tilted mounting is common practice. After the setting has been made, a locked or protected adjustment avoids accidental changes by passing staff.

Technical specifications

Parameter Specification
Type code WTB4FP-22161100A00
Part number 1124609
Product family W4
Functional principle Photoelectric proximity sensor
Functional principle detail Background suppression
Sensing range: Sensing range min. 4 mm
Sensing range: Sensing range max. 220 mm
Sensing range: Adjustable switching threshold for background suppression 15 mm … 220 mm
Sensing range: Reference object Object with 90% remission factor (complies with standard white according to DIN 5033)
Sensing range: Minimum distance between set sensing range and background (black 6% / white 90%) 3 mm, at a distance of 80 mm
Sensing range: Recommended sensing range for the best performance 40 mm … 140 mm
Emitted beam: Light source PinPoint LED
Emitted beam: Type of light Visible red light
Emitted beam: Shape of light spot Point-shaped
Emitted beam: Light spot size (distance) Ø 4.2 mm (130 mm)
Emitted beam: Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) < +/- 1.5° (at TU = +23 °C)
Key LED figures: Normative reference EN 62471:2008-09 | IEC 62471:2006, modified
Key LED figures: LED risk group marking Free group
Key LED figures: Wave length 635 nm
Key LED figures: Average service life 100,000 h at Ta = +25 °C
Adjustment: IO-Link For configuring the sensor parameters and Smart Task functions
MTTFD 642 years
DCavg 0 %
IO-Link ✔ , IO-Link V1.1
Data transmission rate COM2 (38,4 kBaud)
Process data length 16 Bit
Process data structure Bit 0 = switching signal QL1
VendorID 26
DeviceID HEX 0x8002F3
DeviceID DEC 8389363
Declarations and certificates in the data sheet EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; Moroccan declaration of conformity; China RoHS; China Compulsory Product Certification (CCC) exempt; ECOLAB certificate; cULus certificate; IO-Link certificate; Photobiological safety (DIN EN 62471) certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854)

Type code WTB4FP-22161100A00 and what to check before ordering

Wiring data to note: range of 4 mm; response time of ≤ 500 µs; current of ≤ 25 mA, without load. At UB = 24 V; frequency of 1,000 Hz; supply of 10 V DC … 30 V DC.

Housing and environmental limits listed: operating temperature –40 °C … +60 °C; dimensions 16 mm x 40.1 mm x 12.1 mm; light source pinPoint LED; vibration 10 Hz … 1,000 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6)); weight approx. 30 g; enclosure rating IP66 (EN 60529); IP67 (EN 60529); IP69 (EN 60529); wavelength 635 nm.

Before ordering, confirm the sensing range and the adjustable switching distance, the light type (visible red LED or laser), the output type (PNP or NPN or push-pull), the connection (cable or connector and its pin count) and the housing size.

For installation, align the sensor so the object passes through the middle of the sensing range, keep the front screen clean and fix the bracket firmly; vibration of the mount moves the spot as much as it moves the object.

Documents and quotation

You can download the SICK data sheet for WTB4FP-22161100A00 (part no. 1124609) from this page. Send the type code, quantity and delivery location through the RFQ form and Seven Star LLC, an independent supplier in Muscat, will respond with a quotation. Similar products sit under Sensors & Transmitters. Confirm the full code against the device it replaces; if this page and the data sheet ever disagree, follow the data sheet.

Datasheets & Documents
  • PDF Datasheet SICK WTB4FP-22161100A00 official data sheet (part no. 1124609) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Facts checked against SICK's published company history and annual figures, October 2026.

Frequently Asked Questions

What is the SICK WTB4FP-22161100A00?
It is a SICK background suppression sensor (W4), part no. 1124609. The catalogue summary reads: Sensing range min. / max.: 4 mm / 220 mm; Functional principle: Photoelectric proximity sensor; Functional principle detail: Background suppression; Switching output: Push-pull: PNP/NPN.
Which supply voltage applies to the WTB4FP-22161100A00?
Supply voltage is 10 V DC ... 30 V DC. Check the output and interface rows in the table for the signal levels.
What protection rating and temperature range are given?
Enclosure rating: IP66 (EN 60529); IP67 (EN 60529); IP69 (EN 60529). Ambient operating temperature: –40 °C ... +60 °C. Confirm both against the site before ordering.
Does the page include the data sheet?
Yes. The official SICK data sheet for part no. 1124609 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
What should be confirmed before ordering the WTB4FP-22161100A00?
Compare the full type code and part number 1124609 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.