Brand:

Mitsubishi A3NMCA16 Memory Cassette

Description

Function and application

The Mitsubishi A3NMCA16 is a 128 kbyte memory cassette identified in the SV22 programming documentation for the specified A273UHCPU virtual-cam application.

Memory-cassette selection depends on the controller and required program function. The reviewed documentation states that the cam-axis one-revolution limit-output function requires A3NMCA24 or a higher specified cassette.

Technical specifications

Parameter Specification
Model A3NMCA16
Component Memory cassette
Capacity 128 kbytes
Reviewed application Specified A273UHCPU virtual-cam use
Function restriction Cam-axis one-revolution limit output requires A3NMCA24 or higher as specified

Selection and installation

Check the complete motion-controller code, software arrangement and memory requirements before selecting a cassette. The capacity does not establish compatibility with every motion CPU.

Record the existing cassette label, controller and intended cam functions. A larger cassette or another reference remains a separate component selection.

Quotation enquiries

Send Seven Star LLC the A3NMCA16 reference, quantity, controller and base-unit codes, and photographs of the existing label and connections. Identify any required terminal block, cable or accessory separately.

For an installed-system replacement, include the current station configuration and application requirements. Matching a module outline or channel count alone does not establish electrical, software or mechanical compatibility.

Datasheets & Documents
  • PDF Manual SV22 Programming Manual — IB0300029A Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Laboratories that run an NSX-2100 trace sulfur, nitrogen or chlorine analyzer usually know it as a Mitsubishi instrument. The nameplate reads Mitsubishi Chemical Analytech, a name later changed to Nittoseiko Analytech. Seven Star LLC lists the TN6RPC gas tube dryer set for this analyzer and sources NSX-2100 consumables for refinery and fuel-testing laboratories in Oman and the GCC.

Mitsubishi NSX-2100 parts

The NSX-2100 was built with a horizontal or a vertical furnace, and one furnace can serve several detectors. The dryer set removes water from the combustion gas before it reaches the detector. Like the connection kits, it is a consumable, and its part code changes with the analyzer variant.

Ordering NSX-2100 consumables: what we need

Send the part code, for example TN6RPC, together with the exact analyzer model shown on the nameplate (the letters after NSX-2100 indicate furnace type and detectors), the serial number and the detectors fitted. Some original part codes have been replaced by newer ones, so we check each code against the manufacturer's current parts list before quoting.

Frequently Asked Questions

What capacity is listed?
128 kbytes.
What application was reviewed?
The specified A273UHCPU virtual-cam application.
Is compatibility universal across motion CPUs?
No. Match the controller and applicable programming documentation.
Can it provide the described one-revolution limit-output function?
The reviewed manual requires A3NMCA24 or a higher specified cassette for that function.
What details help with an enquiry?
Provide the cassette code, controller, program function and memory requirements.