Brand:

Danfoss VLT AQUA Drive FC 202 Variable Frequency Drive

Description

Overview

Danfoss VLT AQUA Drive FC 202 is a variable frequency drive purpose-built for water and wastewater applications, covering a power range from 0.25 kW up to 90 kW across 200-240V, 380-500V, and 525-600V supply voltages. Unlike a general-purpose drive adapted for pumping duty, the AQUA Drive is engineered from the ground up around the specific failure modes of water utilities and building water systems — dry-running pumps, clogged impellers, water-hammer risk, and cascaded multi-pump stations — and includes dedicated software functions that address each one without requiring an external PLC or additional controller hardware.

As a regional supplier of Danfoss products, Seven Star LLC proudly supplies the VLT AQUA Drive FC 202 to industrial and municipal buyers across Oman and the wider GCC, with application engineering support delivered from within the region. Municipal water authorities, district cooling operators, and RO desalination plants across Muscat, Sohar, and Salalah rely on this traceable supply chain to keep AQUA Drive-controlled pumping stations running reliably.

Operating Principle

The Danfoss VLT AQUA Drive FC 202 operates as a pulse-width-modulated (PWM) frequency converter: it rectifies incoming AC mains to a DC bus, then uses insulated-gate bipolar transistors (IGBTs) to synthesize a variable-frequency, variable-voltage AC output that continuously adjusts motor speed to match actual process demand. Because centrifugal pump power consumption follows the cube of speed, even a modest reduction in speed to match real-time flow or pressure setpoints yields a disproportionately large energy saving compared with a fixed-speed pump throttled by a control valve, which is the core efficiency argument for variable-speed pumping in any water or HVAC circulation system.

What distinguishes the AQUA Drive’s operating principle from a general-purpose VFD is its built-in process intelligence layer. A no-flow/dry-pump detection algorithm monitors motor power and speed signatures to shut a pump down before it runs dry and damages seals or bearings; an end-of-curve detection function protects against operating a pump outside its designed hydraulic curve; a pipe-fill function ramps flow gradually into empty pipework to prevent water-hammer surge; and a built-in cascade controller sequences up to eight pumps in a station to alternate duty and match aggregate output to demand, all executed inside the drive itself without external logic.

Engineering Design of the Danfoss VLT AQUA Drive FC 202

Mechanically and electrically, the Danfoss VLT AQUA Drive FC 202 shares its rugged enclosure and backplate-mounting architecture with the wider Danfoss VLT platform, available in IP20/21 chassis form for panel integration or IP54/55/66 enclosed form for direct installation in a pump room or outdoor pump station without an additional cabinet. The drive is fitted with an integral RFI filter and, on most ratings, a built-in DC choke to suppress harmonic distortion back onto the supply network, which matters in a utility or industrial installation where multiple drives share a common transformer.

The control interface uses the same Local Control Panel (LCP) and menu structure found across the VLT family, so a plant technician already trained on a Danfoss AutomationDrive or HVAC Drive can operate an AQUA Drive with no additional training. Communication options include Modbus RTU as standard with Profibus, Profinet, EtherNet/IP, and BACnet available as fieldbus options, allowing the drive to integrate directly into a SCADA system or building management system used to supervise a water treatment plant, lift station, or district cooling pump house.

Key Features

The VLT AQUA Drive FC 202 packages water-industry-specific intelligence into a standard VLT chassis, reducing the need for external control logic. Its key features include:

  • Power range from 0.25 kW to 90 kW across 200-240V, 380-500V, and 525-600V supply options.
  • Built-in dry-pump and no-flow detection that stops a pump before seal or bearing damage occurs.
  • End-of-curve detection to prevent sustained operation outside the pump’s designed hydraulic curve.
  • Pipe-fill function that ramps flow gradually into empty pipework to prevent water-hammer damage.
  • Integrated cascade controller sequencing up to eight pumps without an external PLC.
  • IP20/21 chassis or IP54/55/66 enclosed variants for panel or direct field installation.
  • Integral RFI filter and DC choke on most ratings for harmonic and supply-quality compliance.
  • Modbus RTU as standard, with Profibus, Profinet, EtherNet/IP, and BACnet options for SCADA/BMS integration.

Industrial Applications

The Danfoss VLT AQUA Drive FC 202 is specified wherever pumped water or wastewater flow must be controlled precisely and efficiently, including municipal water supply and distribution pumping stations, wastewater lift stations and treatment plant process pumps, RO desalination high-pressure and booster pump control, district cooling chilled-water and condenser-water circulation, and irrigation and agricultural pumping schemes. In each case, the Danfoss VLT AQUA Drive FC 202’s built-in process functions reduce energy consumption, reduce mechanical wear from water hammer and dry running, and simplify multi-pump station control without extra hardware.

As the trusted supplier for Danfoss, Seven Star LLC supplies the VLT AQUA Drive FC 202 to municipal water authorities, RO desalination operators, and district cooling providers across the Sohar and Salalah economic zones and throughout the Sultanate of Oman, as well as industrial and commercial buyers across the wider GCC.

Technical Specifications

The Danfoss VLT AQUA Drive FC 202 table below summarizes the principal electrical and functional parameters, and every Danfoss VLT AQUA Drive FC 202 unit supplied by Seven Star LLC is built to this specification.

Parameter Specification
Model Danfoss VLT AQUA Drive FC 202
Power Range 0.25 kW to 90 kW
Supply Voltage 200-240V, 380-500V, 525-600V, 3-phase
Enclosure Ratings IP20 / IP21 (chassis), IP54 / IP55 / IP66 (enclosed)
Control Method PWM frequency conversion with sensorless flux/VVC+ control
Built-In Functions Dry-pump detection, end-of-curve detection, pipe-fill, cascade control (up to 8 pumps)
Communication Modbus RTU standard; Profibus, Profinet, EtherNet/IP, BACnet optional
EMC Filtering Integral RFI filter and DC choke (most ratings)
Typical Application Water supply, wastewater, RO desalination, district cooling pumping

Request a Quote for Danfoss VLT AQUA Drive FC 202

For the Danfoss VLT AQUA Drive FC 202, Seven Star LLC invites water utility engineers, MEP contractors, and plant managers in Oman and across the GCC to submit a formal RFQ for the Danfoss VLT AQUA Drive FC 202. Common power ratings and enclosure types are supplied on request with lead time confirmed at quotation, complete technical datasheets are available on request, and our instrumentation and drives division can advise on cascade configuration, enclosure rating, and fieldbus selection for your specific pumping station.

Browse the full Danfoss range or see more AC Drives products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF datasheet Danfoss VLT AQUA Drive FC 202 Fact Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss VLT AQUA Drive FC 202 Variable Frequency

Answers from our engineering team on installation, compatibility and integration.

01What makes the VLT AQUA Drive FC 202 different from a general-purpose VFD?
The AQUA Drive FC 202 includes built-in water-industry functions such as dry-pump detection, end-of-curve protection, pipe-fill ramping, and a cascade controller for up to eight pumps, all executed inside the drive without needing an external PLC.
02What power and voltage range does the FC 202 cover?
The FC 202 covers 0.25 kW to 90 kW across 200-240V, 380-500V, and 525-600V three-phase supply options, and is available in IP20/21 chassis or IP54/55/66 enclosed formats.
03Can the FC 202 control multiple pumps in a single station?
Yes. The drive has a built-in cascade controller that can sequence and alternate up to eight pumps to match total station output to demand, without requiring a separate PLC or pump controller.
04How does the FC 202 integrate with an existing SCADA or building management system?
The drive supports Modbus RTU as standard, with Profibus, Profinet, EtherNet/IP, and BACnet fieldbus options available, allowing direct integration with most municipal SCADA platforms and commercial building management systems.
05Is Seven Star LLC a trusted supplier for Danfoss products?
Yes, Seven Star LLC supplies Danfoss products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.