Schneider Electric RXZE1M2C RXZ Socket 2 C/O Mixed

Description

RXZE1M2C: RXZ socket for RXM relays, 2 C/O, mixed contacts

The RXZE1M2C is a Schneider Electric Harmony RXZ socket for plug-in relays. Its datasheet lists 2 C/O contacts, a mixed contact arrangement, a conventional free-air thermal current of 7 A, a width of 22.5 mm and screw clamp terminals. The relays it is listed for are: RXM with 2 C/O contact. Seven Star LLC supplies the RXZE1M2C in Oman and the GCC as an independent supplier based in Muscat.

Sockets are bought separately from relays, so the RXZE1M2C is typically ordered together with a matching RXM relay of the contact count listed above, or with a relay already in use that matches the listed compatibility.

Technical specifications of the RXZE1M2C

Parameter Specification
Manufacturer / part number Schneider Electric / RXZE1M2C
Range Harmony Electromechanical Relays
Product type Socket
Device short name RXZ
Compatible relays RXM with 2 C/O contact
Contacts 2 C/O
Contact terminal arrangement Mixed
Conventional free-air thermal current [Ith] 7 A
Rated operational voltage [Ue] 250 V
Rated impulse withstand [Uimp] 4 kV
Overvoltage category III
Pollution degree 3
Terminal type Screw clamp terminals
Tightening torque < 0.8 N.m for M3 screw(s)
Fixing mode By screw (panel) or clip-on, 35 mm symmetrical DIN rail
Width 22.5 mm
Net weight 34 g
Dielectric strength 2500 V
Standards IEC 61984, CE, UL 508
Operating temperature -40–55 °C
Storage temperature -40–55 °C operation
Sold in indivisible quantities of 10
Warranty 18 months

Mounting the RXZE1M2C

The datasheet lists two fixing methods: by screw on a panel, or clip-on on a 35 mm symmetrical DIN rail. The body is 22.5 mm wide and weighs 34 g net. Where the relay will see vibration, a metal maintaining clamp like the RXZ400 can retain it in the socket, and the 18-month warranty listed applies to the socket itself.

Degree of protection is listed as not stated, so the socket is meant for the inside of a panel, not exposed locations.

Selection checklist for the RXZE1M2C

  • Relay: confirm the relay reference is in the compatibility list (RXM with 2 C/O contact).
  • Contacts: 2 C/O.
  • Current: up to 7 A thermal, with the lowest rating in the circuit governing.
  • Terminals: screw clamp terminals.
  • Width: 22.5 mm on the rail.
  • Pack: sold in indivisible quantities of 10.

Contact arrangement of the RXZE1M2C

The datasheet lists a mixed contact terminal arrangement on this socket. The other RXZ sockets in this group are listed as separate, so the arrangement is one of the points that differ between references. The wiring diagram on the datasheet shows which terminal belongs to which pin and must be followed when wiring.

It is rated for 2 C/O contacts with a thermal current of 7 A, so it handles the relay contact set listed under compatibility and not other pole counts. The datasheet states pollution degree 3, overvoltage category III and a 4 kV impulse withstand, which describe the environment and supply category the socket is designed for.

Where the RXZE1M2C is used in Oman and the GCC

In the region, sockets of this type are mostly found in generator and standby power panels, marshalling and interface cabinets and control panels for pumps and compressors. Plug-in relays on sockets allow quick replacement during shutdowns, which is valuable where heat, dust and humidity shorten relay life.

Wiring the RXZE1M2C: screw clamp terminals

The terminal section of the datasheet lists the conductors the this part accepts:

  • Screw clamp terminals, 1 × 0.2–1 × 1.0 mm² (24 AWG–17 AWG) flexible with cable end
  • Screw clamp terminals, 2 × 0.2–2 × 1.0 mm² (24 AWG–17 AWG) flexible with cable end
  • Screw clamp terminals, 1 × 0.5–1 × 1.5 mm² (20 AWG–16 AWG) solid without cable end
  • Screw clamp terminals, 2 × 0.5–2 × 1.5 mm² (20 AWG–16 AWG) solid without cable end

Tighten to < 0.8 N.m for M3 screw(s) on M3 screws and strip the length stated in the datasheet as listed. Cable ends on flexible conductors are the normal practice, and the datasheet differentiates the sizes allowed with and without ferrules.

The RXZE1M2C among RXZ sockets

The RXZ range includes mixed and separate-contact versions, different widths and screw clamp or screw connector terminals. The table shows the references covered in this group.

Part number Contacts Arrangement Thermal current Width Terminals
RXZE1M2C (this page) 2 C/O Mixed 7 A 22.5 mm Screw clamp
RXZE2M114 4 C/O Mixed 10 A 30 mm Screw clamp
RXZE2M114M 4 C/O Mixed 10 A 27 mm Screw connectors
RXZE2S108M 2 C/O Separate 12 A 27 mm Screw connectors
RXZE2S111M 3 C/O Separate 10 A 27 mm Screw connectors
RXZE2S114M 4 C/O Separate 10 A 27 mm Screw connectors

Information to send with an RFQ for the RXZE1M2C

  • Exact reference this part and the quantity.
  • Relay reference that will sit in the socket.
  • Required contacts, 2, 3 or 4 C/O.
  • Preferred terminal style.
  • Matching relays or retaining clamps needed in the same order.
  • Delivery location and timeline.

For critical duties, keep one tested spare of every relay and base type on site, and label the shelf location in the maintenance system so that outage crews can find it quickly.

If the panel is later modified, update the drawings with the exact references fitted, because mismatches between drawings and hardware cost more time than almost any other documentation fault.

When a project is tendered with alternates, state the exact accepted references in the bill of materials, since mixed substitutions between similar-looking relays and bases are a common cause of rework at site.

Store spares in their original packaging in a dry cabinet, away from direct sun and corrosive atmospheres, so that terminals and pins stay clean until they are needed.

Where several panels use the same reference, standardising on one part number simplifies the spares list and reduces the risk of fitting the wrong version during a shutdown.

Check delivery packaging and the reference printed on the part when it arrives, so that any difference from the order is found before installation work starts.

Before ordering, check that the panel layout leaves room for heat to escape, since closed enclosures in hot rooms run closer to component limits than the rated ambient suggests.

Record the installed reference and coil or relay type on the panel schedule, because later fault investigation and replacement depend on knowing exactly what was fitted.

Keep a spare of this reference for sites that run continuously, since a like-for-like replacement keeps the original design intact after a failure.

Documents and quotation

The Schneider Electric datasheet for the RXZE1M2C is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.

Send us the reference RXZE1M2C, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric RXZE1M2C Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RXZE1M2C RXZ Socket 2 C/O Mixed

Answers from our engineering team on installation, compatibility and integration.

01Which relays fit the RXZE1M2C?
The datasheet compatibility list reads: RXM with 2 C/O contact.
02What current is the RXZE1M2C rated for?
A conventional free-air thermal current of 7 A, with rated operational voltage 250 V. The datasheet gives a rated impulse withstand of 4 kV.
03What terminals does the RXZE1M2C have?
Screw clamp terminals, with a mixed contact terminal arrangement and a tightening torque of < 0.8 N.m for M3 screw(s).
04How is the RXZE1M2C mounted?
By screw on a panel or clip-on on a 35 mm symmetrical DIN rail. It is 22.5 mm wide.
05What temperature range applies to the RXZE1M2C?
Operation is listed from -40 to 55 degrees C, with a dielectric strength of 2500 V.