Brand: Schneider Electric
Schneider Electric LC1K0610M7 6 A TeSys K Contactor 220-230 V AC
Description
LC1K0610M7 contactor: a compact 6 A TeSys K mini contactor
The LC1K0610M7 is a Schneider Electric contactor described in the datasheet as: Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 220 to 230VAC coil. The TeSys K contactor is the small-frame member of the TeSys line, used where space in the cabinet is limited. This reference is a three-pole 6 A AC-3 contactor with one NO auxiliary contact integral. Seven Star LLC supplies the LC1K0610M7 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: LC1K marks the TeSys K three-pole contactor, 06 the 6 A frame, 10 the integral auxiliary configuration (one NO, as the datasheet title states) and M7 a 220 to 230 V AC coil.
Technical specifications of the LC1K0610M7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LC1K0610M7 |
| Description | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 220 to 230VAC coil |
| Range | TeSys |
| Product or Component Type | Contactor |
| Device short name | LC1K |
| Device Application | Control |
| Contactor application | Motor control |
| Utilisation category | AC-3; AC-3e; AC-4 |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit <= 690 V AC <= 400 Hz; Signalling circuit <= 690 V AC <= 400 Hz |
| [Ie] rated operational current | 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Control circuit type | AC 50/60 Hz |
| [Uc] control circuit voltage | 220 to 230 V AC 50/60 Hz |
| Motor power kW | 1.5 kW 220 to 230 V AC 50/60 Hz AC-3; 2.2 kW 380 to 415 V AC 50/60 Hz AC-3; 3 kW 440/690 V AC 50/60 Hz AC-3 |
| Auxiliary contact composition | 1 NO |
| [Uimp] rated impulse withstand | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal | 20 A (at 60 °C) for power circuit |
| current | 85 A 50 °C – 5 s for power circuit; 80 A 50 °C – 10 s for power circuit; 60 A 50 °C – 30 s for power circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220 to 230 V conforming to IEC 60947; 110 A at 380 to 400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947 |
| [Icw] rated short-time withstand | 90 A 50 °C – 1 s for power circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947 |
| Average impedance | 3 mOhm – Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 20 °C) |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8 to 1.15 Uc (at <50 °C); Drop-out: >= 0.20 Uc (at <50 °C) |
| Connections – terminals | screw clamp terminals 1 1.5 to 4 mm²solid screw clamp terminals 1 0.75 to 4 mm²flexible without cable end screw clamp terminals 1 0.34 to 2.5 mm²flex |
| Maximum operating rate | 3600 cyc/h |
| Coil technology | Without built-in suppressor module |
| Auxiliary contacts type | Instantaneous 1 NO |
| Signalling circuit frequency | <= 400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Mounting Support | Rail; Plate |
| Operating time | 10 to 20 ms coil de-energisation and NO opening; 10 to 20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Non overlap distance | 0.5 mm |
Power circuit and coil data of the LC1K0610M7
Utilisation categories: AC-3; AC-3e; AC-4. Rated operational voltage: Power circuit <= 690 V AC <= 400 Hz; Signalling circuit <= 690 V AC <= 400 Hz. Rated operational current: 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit. Motor power ratings: 1.5 kW 220 to 230 V AC 50/60 Hz AC-3; 2.2 kW 380 to 415 V AC 50/60 Hz AC-3; 3 kW 440/690 V AC 50/60 Hz AC-3. Coil voltage: 220 to 230 V AC 50/60 Hz. Coil operating limits: Operational: 0.8 to 1.15 Uc (at <50 °C); Drop-out: >= 0.20 Uc (at <50 °C). Inrush coil consumption: 30 VA (at 20 °C). Hold-in consumption: 4.5 VA (at 20 °C).
The coil is a low-power AC type without a built-in suppressor module (see the coil technology row); a separate suppressor can be added in front of sensitive PLC outputs.
Where mini contactors save space and where they do not
A TeSys K occupies about 45 mm of rail width and is useful for small motors, relays-in-place, lighting groups and control duties. The ratings in the datasheet (6 A at 440 V AC-3) mean it is for fractional-kilowatt loads, not for compressors.
The reference also has a hold-in consumption of only a few VA, so a control transformer can feed many of them. But at that size the mechanical and electrical life figures are lower than on the larger Deca contactors, so avoid it on loads with frequent starts and use the larger frame.
Choosing the LC1K0610M7: a short selection checklist
- Load current and category: 6 A at 440 V AC-3, or AC-4 at a reduced current.
- Control supply: 220 to 230 V AC coil.
- One built-in NO auxiliary contact; confirm if more auxiliary blocks are needed.
- Rail or plate mounting, and the width available in the panel.
- Overload protection fitted under the contactor.
- Operating rate (cycles per hour) listed in the datasheet.
Mounting, wiring and service life of the LC1K0610M7
Clip onto 35 mm rail or screw to a plate, wire with the screw clamps and tighten to the torque in the datasheet. Keep conductors within the section range stated.
Maintenance is limited to periodic tightening checks. For mini contactors controlling inductive loads, a coil suppressor or RC network reduces noise on adjacent control circuits.
Where the LC1K0610M7 is used in Oman and the GCC
In Oman and the GCC you see these in small pump and fan starters, HVAC control panels, lighting and power distribution control, and as interposing devices in PLC panels. Use IP-rated enclosures outdoors because the contactor itself is protected only at the finger-safe level.
Dimensions, environment and approvals of the LC1K0610M7
For the LC1K0610M7, plan the mounting space from the datasheet: 45 mm (W) x 58 mm (H) x 57 mm (D). The LC1K0610M7 weighs 0.18 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -50 to 80 °C. Ingress protection: IP2X VDE 0106. Operating altitude: 2000 m without derating. Standards listed: EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ. Certifications listed for this reference: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA.
Information to send with an RFQ for the LC1K0610M7
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric LC1K0610M7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LC1K0610M7 6 A TeSys K Contactor
Answers from our engineering team on installation, compatibility and integration.
01What load can the LC1K0610M7 switch?
The datasheet lists 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit.
02What coil voltage does the LC1K0610M7 use?
Listed as 220 to 230 V AC 50/60 Hz.
03What auxiliary contacts has it?
The composition is 1 NO.
04How wide is the LC1K0610M7?
The width is 45 mm.
05What is the electrical life of the LC1K0610M7?
The datasheet lists 1.3 Mcycles 6 A AC-3 <= 440 V; 1.3 Mcycles 6 A AC-3e <= 440 V; 0.05 Mcycles 36 A AC-4 <= 440 V.