Schneider Electric RE17LAMW Harmony Timer Relay

Description

RE17LAMW: modular timing relay with 0.1 s to 100 h timing

The RE17LAMW is a Schneider Electric Harmony timer relay in the modular timing relay format, component name RE17L. It offers a single timing function (A), a solid state output, a rated supply of 24–240 V AC/DC, and a body 17.5 mm wide. Time can be set from 0.1 s to 100 h through 7 selectable ranges. Seven Star LLC supplies the RE17LAMW in Oman and the GCC as an independent supplier based in Muscat.

Mounting, terminals and environment for the RE17LAMW

The body is 17.5 mm wide, 90 mm high and 72 mm deep and weighs 0.068 kg. It fits a 35 mm DIN rail conforming to IEC 60715. Field wiring uses Screw terminals, 1 × 0.5–1 × 3.3 mm² (20 AWG–12 AWG) solid without cable end, among other permitted conductor combinations, tightened to 0.6–1 N.m conforming to IEC 60947-1.

Protection degrees are listed as IP20 (terminal block) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP50 (front panel) conforming to IEC 60529. Humidity tolerance is 93 % without condensation conforming to IEC 60068-2-30. Vibration resistance is 20 m/s² (f= 10–150 Hz) conforming to IEC 60068-2-6. Operation is listed over -20–60 °C and storage over -30–60 °C. Inside a closed Gulf enclosure in summer the air around a timer sits well above room temperature, so leave space around this unit and keep it away from contactor coils and drives.

Timing functions and time ranges of the RE17LAMW

This unit lists the following timing function, each named by its datasheet code.

  • A: Power on-delay. The timing period begins when the supply is applied, and the output changes state only after it has run out.

The setting covers 0.1 s to 100 h in total, split across these ranges: 0.1 to 1 s; 1 to 10 s; 6 to 60 s; 1 to 10 min; 6 to 60 min; 1 to 10 h; 10 to 100 h. The datasheet gives a setting accuracy of ± 10 % of full scale at 25 °C conforming to IEC 61812-1 and a repeat accuracy of ± 0.5 % conforming to IEC 61812-1, with drift of ± 0.05 %/°C against temperature and ± 0.2 %/V against supply voltage. Pick the range whose upper end is closest above the time you need, because accuracy is quoted as a share of full scale.

Technical specifications of the RE17LAMW

Parameter Specification
Manufacturer / part number Schneider Electric / RE17LAMW
Range of product Harmony Timer Relays
Product type Modular timing relay
Component name RE17L
Number of functions 1
Output type Solid state
Rated supply voltage [Us] 24–240 V AC/DC
Power consumption 0–3 VA at 240 V AC
Repeat accuracy ± 0.5 % conforming to IEC 61812-1
Setting accuracy ± 10 % of full scale at 25 °C conforming to IEC 61812-1
Control type Selector switch front panel; Without test button
Electrical durability 100000000 cycles
Width 17.5 mm
Height / depth 90 mm / 72 mm
Mounting 35 mm DIN rail conforming to IEC 60715
Net weight 0.068 kg
Product certifications GL; CSA; cULus
IP degree of protection IP20 (terminal block) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP50 (front panel) conforming to IEC 60529
Operating temperature -20–60 °C
Relative humidity 93 % without condensation conforming to IEC 60068-2-30
Warranty 18 months

Selection and installation checklist for the RE17LAMW

  • Function: confirm the timing mode (A) against the sequence diagram on the datasheet.
  • Time: choose a range between 0.1 s to 100 h with the upper limit just above your set point.
  • Supply: 24–240 V AC/DC, with the wiring and source verified before energising.
  • Output: solid state output, checked against the real load current and voltage.
  • Fit: 17.5 mm wide, with the mounting type matching the panel.
  • Front panel: Selector switch front panel; Without test button.

Isolate and prove dead before wiring, mount this unit, connect the supply and output terminals, set the function and range, then run the sequence with a test load before the plant is released. Re-check the set time after any change to supply voltage or ambient conditions, and keep a record of the final setting on the panel drawing.

Supply and output of the RE17LAMW

This unit is rated for 24–240 V AC/DC over a range of 0.85–1.1 Us at 50–60 Hz ± 5 %, drawing 0–3 VA at 240 V AC. Because the supply span is wide, a single part can cover several control voltages, though the lowest figure on the span is the practical minimum for a dependable pick-up. The datasheet immunity to microbreaks is 20 ms.

The output is solid state with a nominal current of 0.7 A and a maximum switching voltage of 250 V AC/DC. With no moving contacts the output does not wear mechanically, and the datasheet lists an electrical durability of 100000000 cycles. A solid state stage leaks a little when off, which the datasheet rates at up to 5 mA, so very small loads such as indicator lamps or high-impedance inputs should be checked for false holding.

The RE17LAMW among Harmony timer relays

Width, output type, supply span and function set separate the references. The table compares this unit with its closest neighbours from the same lane.

Part number Functions Width Supply Output Time span
RE17LAMW (this page) A 17.5 mm 24–240 V AC/DC solid state output 0.1 s to 100 h
RE17LCBM C 17.5 mm 24–240 V AC solid state output 0.1 s to 100 h
RE17LHBM H 17.5 mm 24–240 V AC solid state output 0.1 s to 100 h
RE17RAMU A, At 17.5 mm 24–240 V AC / 24 V DC 1 changeover contact 0.1 s to 100 h
RE17RCMU C 17.5 mm 24–240 V AC / 24 V DC 1 changeover contact 0.1 s to 100 h
RE17RLMU L, Li 17.5 mm 24–240 V AC / 24 V DC 1 changeover contact 0.1 s to 100 h

Where the RE17LAMW is used in Oman and the GCC

In Omani and wider GCC plants a timer of this type is typically chosen for delaying the start of fans, pumps or auxiliary drives after a supply is restored so that several loads do not start together, sequencing conveyors, dosing skids and package plant equipment and holding back a permissive until a process has settled. Oil and gas skids, power auxiliaries, desalination and water treatment packages and general industrial panels all use this class of device, and the combination of heat, dust and humidity makes sealed enclosures and clean terminal work important. Where timing is part of a safety function, the project specification and a suitable safety device take precedence over a general-purpose timer.

Information to send with an RFQ for the RE17LAMW

  • Exact reference RE17LAMW and the quantity.
  • Required timing function and set time.
  • Control supply voltage and whether AC or DC.
  • Load type and current on the output.
  • Any matching socket, base or accessory needed.
  • Delivery location and required date.

Documents and quotation

The Schneider Electric datasheet for the RE17LAMW is attached on this page and carries the full specification and function diagrams. Its date is 7 Nov 2026, as printed on the manufacturer’s document, so check the status of the part before ordering.

Send the reference RE17LAMW, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.

Other Models in the Se Timer Relay Range

Seven Star LLC supplies models from the Se Timer Relay range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric RE17LAMW Harmony Timer RelayContactors & Overload RelaysYou are viewing this model
Schneider Electric RE22R1CMR Harmony Timer RelayContactors & Overload RelaysView details
Schneider Electric RE22R1KMR Harmony Timer RelayContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric RE17LAMW Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RE17LAMW Harmony Timer Relay

Answers from our engineering team on installation, compatibility and integration.

01What timing function does the RE17LAMW provide?
The datasheet lists 1 function: A (Power on-delay relay).
02What time range can be set on the RE17LAMW?
The total span is 0.1 s to 100 h, split into 7 ranges: 0.1 to 1 s; 1 to 10 s; 6 to 60 s; 1 to 10 min; 6 to 60 min; 1 to 10 h; 10 to 100 h. Setting accuracy is +/- 10 % of full scale at 25 °C conforming to IEC 61812-1.
03What supply voltage does the RE17LAMW need?
The datasheet gives a rated supply of 24...240 V AC/DC over 0.85...1.1 Us. The unit is 17.5 mm wide.
04What kind of output does the RE17LAMW have?
A solid state output with a nominal current of 0.7 A. Leakage in the off state should be considered for very small loads.
05How is the RE17LAMW mounted?
It clips onto a 35 mm DIN rail conforming to IEC 60715 and is 17.5 mm wide.