Schneider Electric TeSys Ultra Overload Relay

Description

Overview

Schneider Electric TeSys Ultra is an overload relay built for industrial and commercial electrical installations in Oman and across the GCC. It combines rugged construction with proven motor overload protection performance, making it a dependable choice for panel builders and facility engineers on new installations and retrofits alike. The design accounts for the high ambient temperatures and dust loading typical of Gulf industrial sites, and technical support is available through Schneider Electric’s regional engineering network.

With fast quotation turnaround and technical support, Seven Star LLC supplies the Schneider Electric TeSys Ultra with manufacturer documentation and local technical support throughout Oman, Muscat, and the broader GCC. Buyers can source the Schneider Electric TeSys Ultra through Seven Star LLC with a formal quotation, the manufacturer datasheet and technical support with selection.

Operating Principle

The Schneider Electric TeSys Ultra continuously monitors current drawn by a connected motor across all three phases, comparing measured values against a configured thermal model that closely replicates the motor’s actual heating and cooling behaviour rather than relying on a simple fixed time-current curve. When sustained overcurrent conditions indicate a developing overload, the relay trips the associated contactor before winding temperatures reach damaging levels, protecting the motor investment.

In practice, this operating principle gives the TeSys Ultra consistent, repeatable performance over a long service life with minimal maintenance. Behaviour stays predictable under varying load and environmental conditions, and the unit integrates easily into new or existing Schneider Electric systems, including EcoStruxure-enabled monitoring architectures where applicable. That makes it a sound long-term choice for motor overload protection duties in facilities where unplanned downtime is costly.

Engineering Design of the Schneider Electric TeSys Ultra

Housed in a compact, DIN-rail or contactor-mountable enclosure, the Schneider Electric TeSys Ultra integrates adjustable current-setting dials or digital configuration alongside manual and automatic reset options, giving maintenance teams flexibility in how a tripped motor circuit is restored to service. Trip-class selection allows the relay to be matched precisely to the starting characteristics of the driven load.

Each unit goes through Schneider Electric’s standard quality and type-test regime, covering dimensional consistency, insulation performance and mechanical durability over the rated operating life. Installers in Sohar, Salalah and the Muscat governorate report straightforward commissioning and reliable long-term operation when the TeSys Ultra is installed to Schneider Electric guidelines. Seven Star LLC’s technical team can advise on sizing and installation practice before you order.

Key Features

The Schneider Electric TeSys Ultra delivers a combination of engineering benefits that make it a preferred choice for Schneider Electric motor overload protection specifiers across the region:

  • Thermal-modeled overload protection closely matching real motor heating behaviour.
  • Adjustable current settings and selectable trip classes for precise motor matching.
  • Manual or automatic reset options suited to different operational requirements.
  • Compact DIN-rail or direct contactor-mounting for space-efficient panel design.
  • Phase-loss and phase-unbalance protection safeguarding against common supply faults.
  • Clear trip indication simplifying fault diagnosis and maintenance response.
  • Compatibility with the broader Schneider Electric TeSys contactor range.
  • Long service life validated for continuous industrial duty cycles.

Industrial Applications

Pump, fan, and compressor motor circuits across Oman’s water treatment, oil and gas, and manufacturing facilities rely on the Schneider Electric TeSys Ultra to prevent costly motor burnout from sustained overload conditions. Panel builders across Muscat, Sohar, and Salalah specify the Schneider Electric TeSys Ultra as a standard companion to Schneider Electric TeSys contactors in motor starter assemblies.

Seven Star LLC supplies the TeSys Ultra to EPC contractors, panel builders and end users in Oman’s oil and gas, petrochemical, water desalination, district cooling and commercial real estate sectors. From commercial towers in Muscat to the Sohar and Salalah free zones, it is specified for greenfield projects and brownfield upgrades alike, backed by regional supply and support.

Technical Specifications

The table below summarizes the principal technical characteristics of the Schneider Electric TeSys Ultra as published by Schneider Electric; compatible accessories, mounting variants, and rating options for the Schneider Electric TeSys Ultra are available through Seven Star LLC on request.

Parameter Specification
Model Schneider Electric TeSys Ultra
Current Range 0.1–120A (variant dependent)
Trip Class Selectable 10A/10/20/30
Reset Mode Manual or automatic
Protection Type Thermal overload, phase loss, unbalance
Mounting DIN-rail or direct contactor mount
Auxiliary Contacts 1NO+1NC standard
Standard IEC 60947-4-1
Operating Temperature -25°C to +60°C

Request a Quote for Schneider Electric TeSys Ultra Overload Relay

To request a formal RFQ for the Schneider Electric TeSys Ultra, contact Seven Star LLC. We supply Schneider Electric equipment across Oman and the GCC with lead time confirmed at quotation, provide full technical datasheets on request, and offer application engineering support and technical support through our instrumentation and electrical distribution division. Units are supplied with manufacturer documentation, and multi-unit orders for larger projects are welcome.

Other Models in the Schneider Electric TeSys Motor Control Range

Seven Star LLC supplies models from the Schneider Electric TeSys Motor Control range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TeSys Deca LC1D ContactorElectrical & PowerView details
Schneider Electric TeSys D LC1D ContactorElectrical & PowerView details
Schneider Electric TeSys F LC1F400 ContactorElectrical & PowerView details
Schneider Electric TeSys Giga LC1G High-Power ContactorElectrical & PowerView details
Schneider Electric TeSys LRD Thermal Overload RelayElectrical & PowerView details
Schneider Electric TeSys Ultra Overload RelayElectrical & PowerYou are viewing this model
Schneider Electric TeSys Vario Disconnect SwitchCircuit BreakersView details
Schneider Electric TeSys Q Motor Disconnect SwitchCircuit BreakersView details
Schneider Electric TeSys Track Condition Monitoring SystemMotor Soft StartersView details

Related Products

Where the Schneider Electric TeSys Ultra is used

  • Motor starters
  • Pump motors
  • Fan motors
  • Industrial panels
  • Commercial installations

Selection checklist for the Schneider Electric TeSys Ultra

  • Motor current
  • Current setting range
  • Contactor type
  • Setting method
  • Reset mode
  • Mounting method
  • Control voltage
  • Panel space

Installation, commissioning and maintenance notes for the Schneider Electric TeSys Ultra

Mount the relay on the DIN rail or on the contactor and connect the motor circuit. Set the motor current and check the trip path. Check the setting and the connections at regular intervals.

Requesting a quotation for the Schneider Electric TeSys Ultra

Please send the motor data and the control details. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

TeSys Ultra relay type

It is an overload relay.

TeSys Ultra maker

It is made by Schneider Electric.

TeSys Ultra sites

It is built for industrial and commercial electrical installations.

TeSys Ultra users

Panel builders and facility engineers use it on new installations and retrofits.

TeSys Ultra duty

It is used for motor overload protection.

TeSys Ultra current monitoring

It monitors the current drawn by the motor on all three phases.

TeSys Ultra thermal model

It compares the current with a configured thermal model.

TeSys Ultra model basis

The model follows the heating and cooling behaviour of the motor.

TeSys Ultra fixed curve

It does not rely on a simple fixed time-current curve.

TeSys Ultra overload trip

Sustained overcurrent trips the associated contactor.

TeSys Ultra winding protection

The trip comes before the windings reach damaging temperatures.

TeSys Ultra motor protection

Early tripping protects the motor investment.

TeSys Ultra enclosure

It is housed in a compact, DIN-rail or contactor-mountable enclosure.

TeSys Ultra settings

It has adjustable current-setting dials or digital configuration.

TeSys Ultra service life

It gives consistent, repeatable performance over a long service life.

TeSys Ultra maintenance

It needs little maintenance in service.

TeSys Ultra systems

It integrates into new or existing Schneider Electric systems.

TeSys Ultra monitoring

It fits EcoStruxure-enabled monitoring architectures where applicable.

TeSys Ultra environment

The design accounts for high ambient temperatures and dust in Gulf industrial sites.

TeSys Ultra downtime

Reliable protection helps limit unplanned downtime.

TeSys Ultra documentation

Manufacturer documentation is supplied with a quotation.

TeSys Ultra support

Seven Star LLC gives local technical support with selection.

TeSys Ultra delivery

Delivery is arranged to Muscat, Sohar, Salalah and beyond.

Relay records for the Schneider Electric TeSys Ultra

Record the motor current, the relay setting and the date of each check.

Choosing the right Schneider Electric TeSys Ultra setting range

Choose the relay from the motor full-load current and the starter layout.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Circuit breakers make up the largest part of our Schneider Electric listing, from Acti9 modular devices through ComPacT NSX molded case breakers to MasterPact air circuit breakers. Schneider Electric, which dates from 1836 and is headquartered in Rueil-Malmaison, France, is equally established in drives, PLCs and power metering.

Seven Star LLC is an independent supplier of Schneider Electric circuit breakers, Altivar drives, Modicon I/O, power meters, soft starters and dry-type transformers to panel builders and plants in Oman and the GCC.

Schneider Electric product families on this page

Low voltage protection covers Acti9 miniature breakers and their communicating system, ComPacT NSX and PowerPacT H-frame molded case breakers and MasterPact NW air circuit breakers. Altivar 320 variable speed drives appear in several ratings, for example the ATV320U22N4C at 2.2 kW and the ATV320U75N4B at 7.5 kW. Automation is represented by Modicon TM3 expansion modules such as the TM3TM thermocouple input module. Metering includes the EasyLogic PM2000 power meter and iEM2000 modular energy meters. Trihal cast resin transformers and Spacial enclosure accessories complete the electrical distribution side.

Where Schneider Electric equipment is used

Main and distribution switchboards in buildings, utilities and industrial plants carry the breakers and meters. Altivar drives run pumps, fans, conveyors and packaging machines. Modicon controllers with TM3 I/O are common in machine builders' panels, and Trihal transformers serve indoor substations where a dry-type unit is specified.

Ordering Schneider Electric parts: what we need

The commercial reference printed on the product or its carton is the fastest route. For breakers without a reference send rated current, breaking capacity, number of poles, trip unit type, fixed or drawout construction and the accessories fitted, such as shunt trip, auxiliary contacts or motor mechanism. For drives give motor power, supply voltage and the communication option. For transformers send rated power, primary and secondary voltage, vector group and enclosure rating.

Frequently Asked Questions

What is the TeSys Ultra used for?
It is an advanced motor management relay offering comprehensive protection and remote diagnostics beyond basic overload relays.
Does the TeSys Ultra support communication?
Yes, it communicates motor status and fault data over Modbus for remote diagnostics.
What is monitored by the TeSys Ultra?
It monitors motor current, thermal state, and maintains detailed fault history logs.
How is the TeSys Ultra mounted?
It mounts alongside TeSys contactors in motor control center compartments.
Does Seven Star LLC supply TeSys Ultra relays in Oman?
Yes, Seven Star LLC is a trusted supplier of Schneider Electric products supplying TeSys Ultra relays across Oman and the GCC.