- Automation & ControlView all 3,051 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric TeSys D LC1D Contactor
Description
Overview
The Schneider Electric LC1D contactor, sold under the TeSys D range, is the reference IEC electromechanical contactor for motor control and general-purpose switching, spanning the LC1D09 through LC1D150 range at 9–150 A (AC-3). The Schneider Electric LC1D is the most specified contactor family in industrial panel-building because its compact 45–120 mm frame widths cover the overwhelming majority of three-phase motor starters, pump and fan control circuits, and general load switching duties found on a typical process, utility, or building-services site.
With engineering support in Muscat, Seven Star LLC supplies the full Schneider Electric LC1D range on request, with technical support for engineering, procurement, and maintenance teams across Oman and the wider GCC. Each Schneider Electric LC1D order is sourced on request and supplied with manufacturer documentation, with availability and lead time confirmed at quotation.
Operating Principle of the Schneider Electric LC1D Contactor
The Schneider Electric LC1D is an electromagnetically actuated switching device. Energizing the integral coil pulls a moving armature that closes three main power poles simultaneously, connecting the load circuit through silver-alloy contacts rated for repeated make-and-break cycling under AC-3 duty (motor starting and running current). Because the switching action is magnetic rather than manual, the contactor can be commanded remotely from a PLC digital output, a pushbutton station, a motor protection relay, or a building management system, making it the standard interface between low-power control logic and high-power three-phase loads.
When de-energized, spring pressure returns the armature and opens all three poles simultaneously, breaking the circuit cleanly with no risk of contact welding under normal load conditions. The built-in 1 NO + 1 NC auxiliary contact block provides feedback of contactor state to the control system, confirming actual load engagement rather than assuming it from the command signal – a distinction that matters for interlocking, sequencing, and safety-circuit logic. The mechanism requires no routine lubrication and tolerates the dust, vibration, and thermal cycling typical of GCC industrial environments.
Engineering Design of the Schneider Electric LC1D
The Schneider Electric LC1D housing is molded from self-extinguishing thermoplastic with a V1 flame-retardance rating to UL 94 that resists tracking and arc erosion across thousands of switching cycles. Power terminals accept screw clamp or spring (Everlink-ready on select ratings) termination for flat, Phillips, or Pozidriv drivers, and the body mounts on standard 35 mm DIN rail or directly by screw fixing where panel space is constrained. A clear coil-voltage label and a laser-marked model reference on the front face keep field identification fast during panel audits or replacement work.
Coils are available across 24 V DC through 690 V AC, with a low inrush, low-power-consumption design that reduces heat load inside enclosed control cabinets – a genuine advantage in Oman’s high ambient temperatures. Add-on auxiliary contact blocks (front-mount LADN, side-mount LAD8N), timer modules, and surge suppressor modules snap onto the body without tools, letting panel builders configure a base unit into a full motor starter or interlocked switching assembly on the bench rather than in the field.
Key Features of the Schneider Electric LC1D
The Schneider Electric LC1D contactor combines a broad current range with field-proven reliability, and the following features summarize why it remains the default specification across GCC panel shops:
- The Schneider Electric LC1D covers 9 A to 150 A (AC-3) across a single mechanically consistent platform, simplifying spares holding and panel standardization.
- Rated for up to 690 V AC operation with IEC 60947-4-1 and UL/CSA certification for dual-standard export projects.
- Built-in 1 NO + 1 NC auxiliary contacts confirm actual pole state for interlocking and remote monitoring.
- Screw clamp or spring terminal options accommodate both traditional wiring practice and fast tool-free termination.
- Compact 45–120 mm frame width reduces panel footprint versus competing contactor platforms in the same current class.
- Field-installable auxiliary blocks, timer modules, and coil suppressors extend one base contactor into multiple starter configurations.
- Self-extinguishing UL 94 V1 housing withstands high ambient temperature and dust ingress typical of Gulf industrial sites.
- DIN-rail or direct screw mounting supports both new panel builds and retrofit replacement of failed contactors.
Industrial Applications of the Schneider Electric LC1D
Across Oman and the GCC, the Schneider Electric LC1D is the default contactor for direct-on-line and star-delta motor starters driving pumps, compressors, conveyors, and HVAC fans in facilities ranging from district cooling plants and commercial buildings in Muscat to RO desalination trains and utility water networks. Its wide current range means the same platform serves everything from a small dosing pump motor to a mid-size process blower, which simplifies both design standardization and spare-parts inventory for maintenance teams running multi-site operations.
Backed by manufacturer datasheet documentation, Seven Star LLC distributes the Schneider Electric LC1D range to EPC contractors, panel builders, and plant maintenance departments serving the Sohar and Salalah economic zones, where petrochemical, metals, and logistics facilities depend on dependable motor control switching. The Schneider Electric LC1D is equally common in hospitality and hospital electrical rooms across the Sultanate, switching chiller pumps, fresh-air handling units, and standby generator auxiliary loads where uptime and fast local parts availability are operational priorities.
Technical Specifications
The table below summarizes the core electrical and mechanical characteristics of the Schneider Electric LC1D range.
| Parameter | Specification |
|---|---|
| Model | LC1D09 to LC1D150 (TeSys D / TeSys Deca range) |
| Rated Operational Current (AC-3) | 9 A to 150 A (at 440 V AC or below) |
| Rated Operational Voltage | Up to 690 V AC |
| Poles | 3P (3 NO), various auxiliary configurations |
| Auxiliary Contacts | 1 NO + 1 NC built-in (expandable) |
| Coil Voltage Range | 24 V DC – 690 V AC (multiple options) |
| Terminal Type | Screw clamp or spring clamp |
| Mounting | 35 mm DIN rail or screw fixing |
| Enclosure Material | Self-extinguishing thermoplastic; flame retardance V1 conforming to UL 94, fire resistance 850°C conforming to IEC 60695-2-1 |
| Standards | IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 14 |
| Operating Temperature | -40 to +60°C (60 to 70°C with derating) |
| Rated Operational Current (AC-1) | 25 A (LC1D09) to 200 A (LC1D150), at <60°C |
| Motor Power at 380/400 V AC (AC-3) | 4 kW (LC1D09) to 75 kW (LC1D150) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (LC1D09), 8 kV (LC1D95), conforming to IEC 60947 |
| Mechanical Durability | 15 million cycles (LC1D09); 4 million cycles (LC1D95); 8 million cycles (LC1D150) |
| Maximum Operating Rate | 3600 cycles/hour at 60°C (LC1D09); 1200 cycles/hour (LC1D150) |
| Degree of Protection | IP20 front face, conforming to IEC 60529 |
| Operating Altitude | 0 to 3000 m |
| Dimensions (H x W x D) / Weight | LC1D09: 77 × 45 × 86 mm, 0.32 kg; LC1D95: 127 × 85 × 130 mm, 1.61 kg; LC1D150: 158 × 120 × 136 mm, 2.5 kg |
Also available: Lapp OLFLEX Classic 110 Flexible Control Cable
Coil Voltage Codes
Ratings and Terminals Across the Range
Request a Quote for Schneider Electric TeSys D LC1D Contactor
Facility engineers and panel builders in Oman and the GCC can request a formal RFQ for the Schneider Electric LC1D contactor directly from Seven Star LLC, with lead time confirmed at quotation and full technical datasheets available on request. Working closely with plant engineers in the region, our instrumentation and automation division supports specification, sizing, and after-sales service for every Schneider Electric LC1D order – contact Seven Star LLC today to confirm availability and lead time.
Other Models in the Schneider Electric TeSys Motor Control Range
Seven Star LLC supplies models from the Schneider Electric TeSys Motor Control range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric TeSys Deca LC1D Contactor | Contactors & Overload Relays | View details |
| Schneider Electric TeSys D LC1D Contactor | Contactors & Overload Relays | You are viewing this model |
| Schneider Electric TeSys F LC1F400 Contactor | Contactors & Overload Relays | View details |
| Schneider Electric TeSys Giga LC1G High-Power Contactor | Contactors & Overload Relays | View details |
| Schneider Electric TeSys LRD Thermal Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric TeSys Ultra Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric TeSys Vario Disconnect Switch | Circuit Breakers | View details |
| Schneider Electric TeSys Q Motor Disconnect Switch | Circuit Breakers | View details |
| Schneider Electric TeSys Track Condition Monitoring System | Motor Soft Starters | View details |
Related Products
- Schneider Electric TeSys LRD Thermal Overload Relay
- Schneider Electric TeSys F LC1F400 Contactor
- Schneider Electric ATS22D17Q Altistart 22 Soft Starter
- Schneider Electric TeSys Ultra Overload Relay
- Schneider Electric TeSys Deca LC1D Contactor
- Schneider Electric TeSys Giga LC1G High-Power Contactor
See also: Schneider Electric LA1KN40 TeSys K 4 NO Front Contact Block; Schneider Electric LC1D115A6LSE 115 A Contactor 200-500 V AC/DC; Schneider Electric LRE02 EasyPact TVS 0.16-0.25 A Overload Relay.
Datasheets & Documents
- manual Schneider Electric TeSys D Contactor LC1D09-D38 Instruction Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric TeSys D LC1D Contactor
Answers from our engineering team on installation, compatibility and integration.
01What current range does the Schneider Electric LC1D contactor cover?
The TeSys D LC1D range spans 9 A to 95 A at AC-3 duty across the LC1D09 through LC1D95 models, covering the majority of three-phase motor starter and general switching applications on a single mechanically consistent platform.
02Is the LC1D suitable for direct panel replacement without rewiring?
Yes. The LC1D uses standard screw clamp or spring terminals and DIN-rail mounting, so it drops into most existing IEC contactor footprints with minimal rewiring, reducing panel downtime during replacement.
03What coil voltages are available for the LC1D contactor?
Coils are available from 24 V DC through 690 V AC across multiple standard options, allowing the same contactor body to be specified against almost any control voltage used in GCC industrial panels.
04Can the LC1D be combined with an overload relay to form a motor starter?
Yes. The LC1D is designed to pair directly with TeSys LRD or LR9 thermal and electronic overload relays, forming a complete direct-on-line motor starter with coordinated short-circuit and overload protection.
05Is Seven Star LLC an experienced supply partner for Schneider Electric products?
Yes, Seven Star LLC is an experienced supplier of Schneider Electric in Oman and the GCC, supplying LC1D contactors on request with technical support.


















Reviews
There are no reviews yet.