Schneider Electric RXM4AB1B7 RXM 4 C/O Relay 24 V AC
Description
RXM4AB1B7: Harmony RXM 4 C/O relay with 24 V AC coil
The RXM4AB1B7 is a Schneider Electric Harmony RXM miniature plug-in relay with four changeover (C/O) contacts and a 24 V AC coil. This version is without a status LED and has a lockable test button. Its datasheet lists a conventional enclosed thermal current of 6 A, flat faston-type pins and a net weight of 37 g. Seven Star LLC supplies the RXM4AB1B7 in Oman and the GCC as an independent supplier based in Muscat.
Reading the references in this family, the digit after RXM identifies the 4 C/O contact set, the letter pair identifies the contact family (AB: 6 A thermal current, AgNi contacts), the next digit separates the versions without LED (1 without LED), and the last two characters are the coil code, here B7 for 24 V AC. This is our reading of the pattern across the references we reviewed, not a published ordering table, so confirm the full reference before ordering.
The RXM4AB1B7 among RXM 4 C/O relays
Siblings in this lane differ in coil voltage, contact rating, LED and test button. The table lists neighbouring references.
| Part number | Coil | Rated thermal current | Status LED | Lockable test button |
|---|---|---|---|---|
| RXM4AB1B7 (this page) | 24 V AC | 6 A | Without | Yes |
| RXM4AB1BD | 24 V DC | 6 A | Without | Yes |
| RXM4AB1E7 | 48 V AC | 6 A | Without | Yes |
| RXM4AB1ED | 48 V DC | 6 A | Without | Yes |
| RXM4AB1F7 | 120 V AC | 6 A | Without | Yes |
| RXM4AB1FD | 110 V DC | 6 A | Without | Yes |
| RXM4AB1JD | 12 V DC | 6 A | Without | Yes |
Sockets such as the RXZE2M114, RXZE2M114M and RXZE2S114M accept RXM2 and RXM4 relays, and the RXZ-series accessories are matched to the same relay body.
Contact capability of the RXM4AB1B7
The four C/O contacts use AgNi material. The datasheet gives 6 A at 250 V AC and 6 A at 28 V DC on the normally open side, with 3 A on the normally closed side, plus UL-based figures of 6 A at 277 V AC and 8 A at 30 V DC. The maximum switching capacity is 1500 VA/168 W and the minimum is 170 mW at 10 mA, 17 V.
The electrical durability entry reads 100000 cycles for resistive load, against a mechanical durability of 10000000 cycles. Inductive loads such as contactor coils and solenoids reduce contact life, so fit RC or varistor suppression across AC loads and a free-wheeling diode across DC loads, and do not read the resistive life as a guarantee for every load.
Technical specifications of the RXM4AB1B7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RXM4AB1B7 |
| Range | Harmony Electromechanical Relays, RXM series |
| Product type | Miniature plug-in relay |
| Contacts | 4 C/O |
| Status LED | Without |
| Control type | Lockable test button |
| Control circuit voltage [Uc] | 24 V AC 50/60 Hz |
| Rated operational voltage limits | 19.2–26.4 V AC V AC |
| Drop-out voltage threshold | ≥ 0.15 Uc |
| Average coil resistance | 180 Ohm at 20 °C ± 15 % |
| Average coil consumption | 1.2 at 60 Hz |
| Conventional enclosed thermal current [Ithe] | 6 A |
| Maximum switching capacity | 1500 VA/168 W |
| Minimum switching capacity | 170 mW at 10 mA, 17 V |
| Contacts material | AgNi |
| Mechanical durability | 10000000 cycles |
| Electrical durability | 100000 cycles for resistive load |
| Insulation voltage [Ui] | 250 V conforming to IEC |
| Pin shape | Flat (faston type) |
| Operating position | Any position |
| Operating rate | ≤ 1200 cycles/hour under load; ≤ 18000 cycles/hour no-load |
| Net weight | 37 g |
| Storage temperature | -40–85 °C |
| Warranty | 18 months |
Selection checklist for the RXM4AB1B7
- Coil: 24 V AC, with the real supply inside 19.2–26.4 V AC V AC.
- Load: up to 6 A thermal current, checked per contact against the AC or DC rating.
- Indication: no LED on this version.
- Manual override: lockable test button present.
- Base: an RXM-compatible socket with the right terminal style.
- Quantity: relays are sold in indivisible quantities, so confirm the pack size with us.
Indication and manual operation on the RXM4AB1B7
The RXM4AB1B7 has a lockable test button but no status LED. The button lets a technician actuate the contacts by hand and lock them over during commissioning, but there is no indicator to show coil status, so a meter or the connected load is the check.
When choosing between versions, remember that these features are fixed on the relay itself. A relay without LED cannot be upgraded and has to be replaced by the LED variant if indication is later required, and the same goes for the test button.
Coil of the RXM4AB1B7: 24 V AC
24 volts is the most common control voltage in PLC cabinets and instrument marshalling panels, so this coil value fits the output of a typical controller or supply directly. The datasheet gives operating voltage limits of 19.2–26.4 V AC V AC, which is the window within which the coil should be driven. A coil resistance of 180 Ohm at 20 °C ± 15 % and a consumption of 1.2 at 60 Hz describe how much the control source must supply.
The drop-out threshold is listed as ≥ 0.15 Uc, meaning the relay releases when the coil voltage falls to that fraction of 24 V AC. On AC circuits, check how the supply behaves during dips and ripple, because a voltage that hovers between pick-up and drop-out causes chatter. AC coils also hum if the supply frequency or waveform is poor.
Information to send with an RFQ for the RXM4AB1B7
- Exact reference RXM4AB1B7 and the quantity.
- Coil supply voltage and type, 24 V AC here.
- Load type and current on the contacts.
- Socket or base type already installed.
- Other coil voltages or LED versions needed in the same order.
- Delivery location and timeline.
For critical duties, keep one tested spare of every relay and base type on site, and label the shelf location in the maintenance system so that outage crews can find it quickly.
If the panel is later modified, update the drawings with the exact references fitted, because mismatches between drawings and hardware cost more time than almost any other documentation fault.
When a project is tendered with alternates, state the exact accepted references in the bill of materials, since mixed substitutions between similar-looking relays and bases are a common cause of rework at site.
Store spares in their original packaging in a dry cabinet, away from direct sun and corrosive atmospheres, so that terminals and pins stay clean until they are needed.
Documents and quotation
The Schneider Electric datasheet for the RXM4AB1B7 is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.
Send us the reference RXM4AB1B7, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric RXM4AB1B7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RXM4AB1B7 RXM 4 C/O Relay 24 V AC
Answers from our engineering team on installation, compatibility and integration.
01What coil does the RXM4AB1B7 use?
A 24 V AC coil with operating voltage limits of 19.2–26.4 V AC V AC. The datasheet lists a drop-out threshold of >= 0.15 Uc and an average coil resistance of 180 Ohm at 20 °C +/- 15 %.
02What contacts does the RXM4AB1B7 have?
Four C/O contacts with AgNi material and a conventional enclosed thermal current of 6 A. The maximum switching capacity is 1500 VA/168 W.
03Does the RXM4AB1B7 have an LED or test button?
Status LED: without. Control type: lockable test button.
04What socket fits the RXM4AB1B7?
The datasheet lists flat faston-type pins and RXM compatibility. Sockets such as RXZE2M114 and RXZE2S114M are listed for RXM4 relays; confirm the terminal style you need.
05How long does the RXM4AB1B7 last?
Mechanical durability is 10000000 cycles. Electrical durability is listed as 100000 cycles for resistive load.


















Reviews