Schneider Electric LC1D09M7 TeSys D 9 A Contactor 220 V AC

Description

LC1D09M7 contactor: 9 A TeSys D contactor with a 220 V AC coil

The LC1D09M7 is a Schneider Electric TeSys D contactor with three normally open power poles, rated 9 A in AC-3 up to 440 V, with a 220 V AC 50/60 Hz coil. It is one of the smallest frames of the LC1D series and the datasheet range line reads TeSys Deca Advanced. The LC1D09M7 also has a built-in auxiliary set of 1 NO + 1 NC. Seven Star LLC supplies the LC1D09M7 in Oman and the GCC as an independent supplier based in Muscat.

Decoding the reference: LC1D is the TeSys D contactor, 09 is the 9 A frame, and M7 is the 220 V AC 50/60 Hz coil code that the title states. The datasheet title mentions AC-3, a voltage of up to 440 V and 9 A, so the three figures together describe a small motor starter contactor.

Technical specifications of the LC1D09M7

Parameter Specification
Manufacturer / part number Schneider Electric / LC1D09M7
Description Product datasheet TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 220 V AC coil
Range of product TeSys Deca Advanced
Product or component type Contactor
Device short name LC1D
Contactor application Motor control; Resistive load
Utilisation category AC-3; AC-3e; AC-1; AC-4
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25 to 400 Hz; Power circuit: <= 300 V DC
[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Motor power kW 2.2 kW at 220/230 V AC 50/60 Hz (AC-3); 4 kW at 380/400 V AC 50/60 Hz (AC-3); 4 kW at 415/440 V AC 50/60 Hz (AC-3); 5.5 kW at 500 V AC 50/60 Hz (AC-3)
Motor power hp 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal 25 A (at 60 °C) for power circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947; are subject to change – check with your local distributor.
[Icw] rated short-time withstand 105 A 40 °C – 10 s for power circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1; 25 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit
Power dissipation per pole 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 0.6 Mcycles 25 A AC-1 at Ue <= 440 V; 2 Mcycles 9 A AC-3 at Ue <= 440 V; 2 Mcycles 9 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3 to 0.6 Uc (-40 to 70 °C):drop-out AC 50/60 Hz; 0.8 to 1.1 Uc (-40 to 60 °C):operational AC 50 Hz; 0.85 to 1.1 Uc (-40 to 60 °C):operational AC 60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2 to 3 W at 50/60 Hz

Motor ratings of the LC1D09M7 by voltage

The datasheet gives AC-3 motor power as 2.2 kW at 220/230 V, 4 kW at 380/400 V, 4 kW at 415/440 V, 5.5 kW at 500 V and 5.5 kW at 660/690 V, all at 50/60 Hz. The same values are listed under AC-3e. In horsepower, the datasheet lists 1 hp at 230/240 V single phase, 2 hp at 200/208 V and 230/240 V three phase, 5 hp at 460/480 V and 7.5 hp at 575/600 V.

Resistive duty is listed under AC-1 at 25 A up to 440 V, which is where the large gap between 9 A and 25 A comes from: motor starting currents are many times the running current, while resistive loads have none.

Coil, timing and durability data for the LC1D09M7

The coil of the LC1D09M7 is 220 V AC at 50/60 Hz, with an inrush of 70 VA at 50 Hz and cos phi 0.75, and a hold-in of 7 VA at 50 Hz and cos phi 0.3. Operating limits are 0.8 to 1.1 Uc at 50 Hz and 0.85 to 1.1 Uc at 60 Hz up to 60 °C, with drop-out between 0.3 and 0.6 Uc. The datasheet states that the coil has no built-in suppressor module. Operating time is 12 to 22 ms closing and 4 to 19 ms opening.

Mechanical durability of the LC1D09M7 is 15 Mcycles. Electrical durability is 2 Mcycles at 9 A AC-3 and 0.6 Mcycles at 25 A AC-1, both at up to 440 V. The maximum rate is 3600 cycles per hour at 60 °C.

Built-in auxiliary contacts and safety data of the LC1D09M7

The contactor includes a 1 NO + 1 NC auxiliary contact set, described as mechanically linked per IEC 60947-5-1, with the NC contact being a mirror contact per IEC 60947-4-1. The non-overlap time between NC and NO is 1.5 ms. The signalling circuit is protected by a 10 A gG fuse and has a 5 mA, 17 V minimum switching level.

For safety applications the datasheet gives B10d values for the LC1D09M7: 1369863 cycles at nominal load and 20000000 cycles with mechanical load, under EN/ISO 13849-1. These help a machine builder calculate the performance level of a safety function that uses the contactor.

Fitting the LC1D09M7 in a starter: protection and coordination

The datasheet lists associated fuses of 25 A gG for type 1 coordination and 20 A gG for type 2 coordination at up to 690 V. A motor starter is normally built from this contactor, a thermal overload relay or a motor circuit-breaker, and a short-circuit device. The correct combination depends on the motor and is chosen from the coordination tables.

Before ordering the LC1D09M7, run through these points: motor up to 4 kW at 400 V in AC-3; coil 220 V AC 50/60 Hz matching the panel; the built-in 1 NO + 1 NC, with extra blocks such as the LADN22 on the front; an overload relay or motor breaker added; 45 mm of rail width; and the real duty checked against the LC1D09M7 ratings.

The LC1D09M7 mounts on a rail or a plate and measures 77 mm high, 45 mm wide and 86 mm deep with a net weight of 0.32 kg. Power and control terminals are screw clamp types for 1 to 4 mm² flexible wire, tightened at 1.7 N.m.

Environment, approvals and mounting limits of the LC1D09M7

The permissible ambient temperature around the device is -40 to 60 °C, with operation at 60 to 70 °C possible with derating, and altitude is 0 to 3000 m. The datasheet lists IP20 on the front face, protective treatment TH, climatic withstand per IACS E10 and damp heat, fire resistance of 850 °C and flame retardance V1 per UL 94.

Certifications listed are UL, CCC, CSA, Marine, UKCA, EAC and CB Scheme. Because the marine listing appears on the datasheet, the contactor is relevant to shipboard and offshore panels, subject to the approval details of the specific installation.

Where the LC1D09M7 is used in Oman and the GCC

Small three-phase motors up to 4 kW at 400 V are everywhere in the Gulf: circulation pumps, dosing pumps, extraction fans, conveyors and small compressors. The LC1D09M7 is the commodity starter element for these, and its 50/60 Hz coil allows the same unit to serve both 50 Hz local panels and imported 60 Hz equipment.

Hot switchrooms demand attention to ambient derating above 60 °C, and dusty sites need clean enclosures with filters on the ventilation.

Information to send with an RFQ for the LC1D09M7

  • Full reference and quantity required
  • Motor power, voltage and starting duty
  • Coil voltage and frequency available in the panel
  • Overload relay or breaker it will be combined with
  • Delivery location and timing

Documents and quotation

A datasheet for the LC1D09M7 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric LC1D09M7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LC1D09M7 TeSys D 9 A Contactor

Answers from our engineering team on installation, compatibility and integration.

01What is the AC-3 current of the LC1D09M7?
9 A at up to 440 V. See the datasheet linked on this page for the full figures.
02What motor power does the LC1D09M7 handle at 400 V?
4 kW at 380/400 V in AC-3. See the datasheet linked on this page for the full figures.
03What coil does the LC1D09M7 have?
220 V AC at 50/60 Hz. See the datasheet linked on this page for the full figures.
04Does the LC1D09M7 include auxiliary contacts?
Yes, a 1 NO + 1 NC set is built in. Check that this arrangement matches your control circuit before ordering.
05What size is the LC1D09M7?
77 mm high, 45 mm wide, 86 mm deep, 0.32 kg.