- Automation & ControlView all 2,220 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Industrial Computers
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric ABL8RPM24200 Phaseo 24 V 20 A Power Supply
Description
ABL8RPM24200: Phaseo regulated switch mode supply, 24 V DC 20 A
The ABL8RPM24200 is a 480 W Phaseo supply that is aimed at larger panels, accepting either 100–120 V single phase or 200–240 V phase to phase. It is a regulated switch mode power supply in Schneider Electric’s Modicon Power Supply (Phaseo) offer, giving 24 V DC at 20 A, equal to 480 W. At 20 A it can feed a full PLC rack plus field devices from a single module, which cuts the number of supplies to inspect during maintenance. Seven Star LLC supplies the ABL8RPM24200 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: ABL8 is the Phaseo prefix, the letters RPM identify the model line, 24 the output voltage, and the final digits (200) correspond to the rated output current in tenths of an amp (here 20 A). This is our reading of the pattern and the datasheet remains the reference for ordering.
Where the ABL8RPM24200 fits in Oman and the GCC
This unit is suited to PLC cabinets, large instrument racks and process skids where one 20 A rail replaces several small supplies. The wide input window of Phaseo supplies is practical in the region because industrial plants mix 230 V, 400 V and sometimes 415 V sources, and imported machines arrive with their own voltage assumptions. High ambient temperatures are the main design consideration: the unit is rated for 50 °C without derating, so cabinets in direct sun, desalination plant rooms or switch rooms without air conditioning should be checked against that value, with ventilation or sunshields where needed.
Supplying the ABL8RPM24200: input bands, inrush and filtering
The datasheet lists the nominal input as 100–120 V AC single phase, terminal(s): N-L1; 200–240 V AC phase to phase, terminal(s): L1-L2, with accepted limits of 85–132 V AC and 170–264 V AC. Choose between the single-phase 100–120 V connection (N and L1) and the phase-to-phase 200–240 V connection (L1 and L2) when you wire the unit. The inrush current is 30 A and efficiency is 88 %, which leaves 57.6 W of heat inside the housing at full load.
A power factor correction filter conforming to IEC 61000-3-2 is listed as provided equipment, together with an anti-harmonic filter for low-frequency harmonic currents; the quoted power factor is 0.68 at 240 V AC and 0.69 at 120 V AC. Terminals are screw type: 3 × 0.5–3 × 4 mm² (22–12 AWG) for the input, and 4 × 0.5–4 × 4 mm² (22–12 AWG) for the output.
ABL8RPM24200 technical data
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / ABL8RPM24200 |
| Range | Modicon Power Supply |
| Type | Regulated switch mode |
| Nominal input voltage | 100–120 V AC single phase, terminal(s): N-L1 ; 200–240 V AC phase to phase, terminal(s): L1-L2 |
| Input voltage limits | 85–132 V AC and 170–264 V AC |
| Rated power | 480 W |
| Output voltage / current | 24 V DC / 20 A |
| Output voltage adjustment | 24–28.8 V |
| Temporary boost current | 1.5 × In for 4 s |
| Efficiency | 88 % |
| Power dissipation | 57.6 W |
| Inrush current | 30 A |
| Power factor | 0.68 at 240 V AC; 0.69 at 120 V AC |
| Output coupling | Series / Parallel |
| Mounting | 35 × 7.5 mm symmetrical DIN rail / 35 × 15 mm symmetrical DIN rail |
| Operating position | Vertical |
| Dimensions (W × H × D) | 146 × 125 × 145 mm |
| Net weight | 1.6 kg |
| Protection degree | IP20 conforming to IEC 60529; IP10 |
| Operating temperature | 50–60 °C with derating factor mounting position A < 2000 m ; −25–50 °C without derating mounting position A < 2000 m |
| Operating altitude | 2000 m |
Mounting and cooling the ABL8RPM24200
The unit measures 146 × 125 × 145 mm and weighs 1.6 kg. It clips onto a 35 × 7.5 mm or 35 × 15 mm DIN rail and must be mounted vertically. The nominal ambient temperature for the universal Phaseo supplies is 50 °C, with derating up to a maximum of 60 °C; the datasheet text for this reference reads 50–60 °C with derating factor mounting position A < 2000 m and −25–50 °C without derating mounting position A < 2000 m. Protection is IP20, so the unit belongs inside an enclosure, and the altitude limit is 2000 m.
Two LEDs report status: one (green and red) for output voltage and one (green, red and orange) for output current. A removable screw terminal block, 2 x 2.5 mm², is provided for the diagnostic relay, so the supply can report a fault to a PLC input. Dielectric strength is 2500 V between input and ground, 3000 V between input and output, 500 V between output and ground.
Phaseo universal range around the ABL8RPM24200
Within this set the references step up in power: ABL8RPS24030 (72 W), ABL8RPS24050 (120 W), ABL8RPM24200 (480 W) and the three-phase ABL8WPS24400 (960 W). The datasheet allows series or parallel connection of at most two units, only recommended for identical references; for better availability supplies can instead be paralleled through the ABL8RED24400 redundancy module.
| Reference | Nominal input | Rated power | Output current | W × H × D | Weight |
|---|---|---|---|---|---|
| ABL8RPS24030 | 100–120 V AC single phase / 200–500 V AC phase to phase | 72 W | 3 A | 45 × 125 × 125 mm | 0.3 kg |
| ABL8RPS24050 | 100–120 V AC single phase / 200–500 V AC phase to phase | 120 W | 5 A | 56 × 143 × 125 mm | 0.7 kg |
| ABL8RPM24200 | 100–120 V AC single phase / 200–240 V AC phase to phase | 480 W | 20 A | 146 × 125 × 145 mm | 1.6 kg |
| ABL8WPS24400 | 380–500 V AC three phase | 960 W | 40 A | 166 × 143 × 160 mm | 2.7 kg |
Output, boost and protection of the ABL8RPM24200
The output is 24 V DC and can be trimmed over 24–28.8 V, which helps compensate cable drop on long runs. For short overloads the unit supplies a temporary boost of 1.5 times the nominal current for 4 seconds, useful for inrush of solenoid valves and contactors. At the nominal figure the ABL8RPM24200 supplies 20 A; a planning load of 80 % is about 16.0 A.
Protections listed are overload and short-circuit with manual or automatic reset, overvoltage at 30–32 V with manual reset, undervoltage tripping when the output falls below 21.6 V, and thermal protection with automatic reset. The datasheet notes that derating should be considered in extreme conditions: intensive operation near nominal current at high temperature, an output set above 24 V, or parallel connection to increase total power.
Selection checklist for the ABL8RPM24200
- Sum the 24 V load below 20 A and decide how much margin the hottest cabinet needs.
- Match the mains: 100–120 V AC single phase / 200–240 V AC phase to phase; limits 85–132 V AC and 170–264 V AC.
- Check the footprint of 146 × 125 × 145 mm and the vertical mounting rule.
- Decide whether a diagnostic relay is needed and whether two units must run redundantly through a separate redundancy module.
- State the highest ambient temperature so derating can be assessed.
Information to send with an RFQ for the ABL8RPM24200
- Reference ABL8RPM24200 and quantity.
- Mains system at site (single-phase or three-phase) and voltage.
- Total 24 V load and number of units needed, including any redundancy plan.
- Maximum cabinet temperature.
- Delivery location and required date.
Documents and quotation
The manufacturer datasheet for the ABL8RPM24200 is attached on this page and carries the complete specification set, including the dimension drawings and the derating information. Compare the datasheet revision with your project documents before you freeze a bill of materials.
Send us the reference ABL8RPM24200, the quantity and the delivery location, and Seven Star LLC will reply to your request for quotation. We work as an independent supplier based in Muscat and serve customers across Oman and the GCC.
Other Models in the Se Abl8 Range
Seven Star LLC supplies models from the Se Abl8 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric ABL8RPS24100 Phaseo 24 V DC 10 A PSU | Power Modules | View details |
| Schneider Electric ABL8REM24050 Phaseo 24 V DC 5 A Power Supply | Power Modules | View details |
| Schneider Electric ABL8RPM24200 Phaseo 24 V 20 A Power Supply | Power Modules | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric ABL8RPM24200 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric ABL8RPM24200 Phaseo 24 V 20 A
Answers from our engineering team on installation, compatibility and integration.
01What does the ABL8RPM24200 output?
It delivers 24 V DC at 20 A, which is 480 W. The output can be adjusted over 24–28.8 V.
02What supply does the ABL8RPM24200 need?
The datasheet lists 100–120 V AC single phase, terminal(s): N-L1; 200–240 V AC phase to phase, terminal(s): L1-L2 with limits of 85–132 V AC and 170–264 V AC.
03Can the ABL8RPM24200 be paralleled?
The datasheet allows at most two units in series or in parallel, recommended only for identical references. For redundancy it points to the ABL8RED24400 redundancy module.
04What protections does the ABL8RPM24200 include?
Overload and short-circuit (manual or automatic reset), overvoltage (30–32 V, manual reset), undervoltage (trips below 21.6 V) and thermal protection with automatic reset.
05How is the ABL8RPM24200 installed?
It clips onto a 35 mm DIN rail in a vertical position. Size is 146 × 125 × 145 mm and weight 1.6 kg; protection is IP20.


















Reviews