Schneider Electric A9C22512 iCT 16 A 2NO 220 V Contactor

Description

A9C22512: two-pole 16 A contactor with a 220 V coil

The A9C22512 is a Schneider Electric Acti9 contactor listed in the datasheet as: iCT 16A 2NO 220V 50Hz contactor. The A9C22512 is a two-pole 16 A contactor in an 18 mm body with a 220 V AC coil. It is the lightest frame in this iCT group, intended for small single-phase loads and for installations where the control supply is exactly 220 V and not the 230 to 240 V of the other references. Seven Star LLC supplies the A9C22512 in Oman and the GCC as an independent supplier based in Muscat.

The coding gives A9C family, 16 A, two normally open poles (2P, 2 NO), coil 220 V AC 50 Hz. The datasheet lists 16 A AC-7A and 6 A AC-7B, and the compatible accessory code is given as IACTs, a narrower list than for the larger frames; the depth is 68.5 mm.

Technical specifications of the A9C22512

Parameter Specification
Manufacturer / part number Schneider Electric / A9C22512
Description iCT 16A 2NO 220V 50Hz contactor
Range of product Acti9
Product name Acti9 iCT
Product or component type Contactor
Device short name iCT
Device application Motor-heating-lighting
Poles 2P
[Ie] rated operational current 16 A AC-7A; 6 A AC-7B
Pole contact composition 2 NO
Network type AC
Control type Remote control
[Uc] control circuit voltage 220 V AC 50 Hz
Network frequency 50 Hz
[Ue] rated operational voltage 250 V AC 50 Hz
Maximum power 1.3 W at 250 V AC
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand 4 kV
Control signal type Maintained
Switching frequency 100 switching operations/day
Local signalling Action indicator
Hold-in power consumption in VA 3.8 VA
Inrush power in VA 15 VA
Mounting mode Clip-on
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 68.5 mm
Mechanical durability 1000000 cycles
Electrical durability 100000 cycles IEC/EN 61095 16 A 50 Hz AC-7A; 30000 cycles IEC/EN 61095 6 A 50 Hz AC-7B; 30000 cycles IEC/EN 61095 50 Hz AC-7C
Tightening torque Control circuit: 0.8 N.m; Power circuit: 0.8 N.m
Market segment Residential; Small commercial
Standards IEC/EN 61095
Noise level 30 dB
IP degree of protection IP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529
Relative humidity 95 % at 55 °C
Operating altitude 2000 m
Ambient air temperature, operation -5 to 60 °C
Ambient air temperature, storage -40 to 70 °C

Power circuit and coil data of the A9C22512

The rated operational current is 16 A AC-7A; 6 A AC-7B. Rated operational voltage: 250 V AC 50 Hz. Maximum power figure: 1.3 W at 250 V AC. Coil voltage: 220 V AC 50 Hz. Hold-in consumption: 3.8 VA. Inrush consumption: 15 VA. Rated insulation voltage: 500 V AC 50/60 Hz. Rated impulse withstand voltage: 4 kV. Mechanical durability: 1000000 cycles.

Coil consumption is 3.8 VA hold-in and 15 VA inrush, noticeably higher than the 2.7 VA and 9.2 VA of the 230 to 240 V coils in the 25 A, two-pitch references, so the coil figures do not simply follow the current rating. Compared with the A9C20732, which has the same two-pitch width at 25 A and a 230 to 240 V coil, this contactor trades current for a coil voltage that suits some older 220 V control supplies.

AC-7A and AC-7B ratings of the A9C22512: reading the load categories

The datasheet lists the load ratings by category from IEC/EN 61095. AC-7A covers slightly inductive loads of household and similar use, which is where lighting, heating and resistive circuits belong. AC-7B is the rating for the motor loads of household appliances and is always much lower than the AC-7A figure. A designer who reads only the headline current can therefore overload the contacts with a motor-type load; reading the category avoids that.

Electrical durability in the datasheet: 100000 cycles IEC/EN 61095 16 A 50 Hz AC-7A; 30000 cycles IEC/EN 61095 6 A 50 Hz AC-7B; 30000 cycles IEC/EN 61095 50 Hz AC-7C.

How the A9C22512 compares with neighbouring iCT contactors

The A9C20868 differs in poles 4P against 2P here; contacts 2 NO + 2 NC against 2 NO here; coil 220 to 240 V AC 50 Hz against 220 V AC 50 Hz here; current 63 A AC-7A against 16 A AC-7A here; width 54 mm against 18 mm here. The A9C20864 differs in poles 4P against 2P here; contacts 4 NO against 2 NO here; coil 220 to 240 V AC 50 Hz against 220 V AC 50 Hz here; current 63 A AC-7A against 16 A AC-7A here; width 54 mm against 18 mm here.

The table below lists the iCT references of this group with their main differences so that a purchase order can be checked against the family.

Reference Poles / contacts Rated current Coil Width
A9C20731 1P / 1 NO 25 A AC-7A, 8.5 A AC-7B 230 to 240 V AC 50 Hz 18 mm
A9C20732 2P / 2 NO 25 A AC-7A, 8.5 A AC-7B 230 to 240 V AC 50 Hz 18 mm
A9C20834 4P / 4 NO 25 A AC-7A, 8.5 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20838 4P / 2 NO + 2 NC 25 A AC-7A, 8.5 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20842 2P / 2 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20843 3P / 3 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C20844 4P / 4 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C20864 4P / 4 NO 63 A AC-7A 220 to 240 V AC 50 Hz 54 mm
A9C20868 4P / 2 NO + 2 NC 63 A AC-7A, 20 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C22512 (this page) 2P / 2 NO 16 A AC-7A, 6 A AC-7B 220 V AC 50 Hz 18 mm

Selection checklist for the A9C22512

  • Confirm the control supply is 220 V and not 230 to 240 V; choose the A9C20732 if the latter.
  • Check the load against 16 A AC-7A and 6 A AC-7B before use.
  • Match coil voltage and frequency to the control supply; this reference uses 220 V AC 50 Hz.
  • Check the width of 18 mm (2 pitches) against free rail space and spare gaps for heat.
  • Confirm the number of operations per day stays within the datasheet figure.

Mounting, wiring and maintenance of the A9C22512

Mount the contactor on a 35 mm DIN rail by clipping it on; no screws are needed for the body. Use the tightening torques from the datasheet: Control circuit: 0.8 N.m, Power circuit: 0.8 N.m. Leave a gap beside the contactor when several are fitted in a row, because every energised coil dissipates heat, and in a warm Gulf plant room the margin to the -5 to 60 °C operating limit is often small. Label the coil terminals A1 and A2 clearly, since a mistaken coil connection is the most common commissioning error.

The datasheet lists the environment as -5 to 60 °C in operation and -40 to 70 °C in storage, relative humidity of 95 % at 55 °C, an altitude limit of 2000 m and pollution degree 2.

Where the A9C22512 is used in Oman and the GCC

At 16 A, the contactor suits small water heaters, lighting circuits, door-motor supplies and fan circuits in small premises. In the GCC a 220 V control supply is still found in older imported equipment and in some industrial control transformers, which is where this reference is most often requested as a like-for-like replacement.

Check the real control voltage at site: a coil rated at 220 V that is fed from a 240 V network should be assessed against the voltage tolerance in the manufacturer’s documentation, because the datasheet summarised here does not give coil limits for this reference.

Information to send with an RFQ for the A9C22512

  • Full reference (A9C22512) and quantity required
  • Supply and control voltage at site, with the frequency
  • Existing panel, rail and neighbouring devices it must fit beside
  • Delivery location and timing
  • Whether it is a spare, a like-for-like replacement or a new installation
  • Load type and current: lighting, heating or motor-type

Documents and quotation

A datasheet for the A9C22512 is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it should be read together with the manufacturer’s installation instructions for the final design.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Acti9 Ict Range

Seven Star LLC supplies models from the Se Acti9 Ict range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric A9C20731 iCT 25 A 1NO 230-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20732 iCT 25 A 2NO 230-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20834 iCT 25 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20838 iCT 25 A 2NO+2NC 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20842 iCT 40 A 2NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20843 iCT 40 A 3NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20844 iCT 40 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20864 iCT 63 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20868 iCT 63 A 2NO+2NC 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C22512 iCT 16 A 2NO 220 V ContactorContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric A9C22512 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9C22512 iCT 16 A 2NO 220 V

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the A9C22512?
The datasheet gives 16 A AC-7A, 6 A AC-7B.
02What coil or control voltage does the A9C22512 use?
The datasheet lists 220 V AC 50 Hz. Check this against the real control supply before ordering.
03What are the dimensions of the A9C22512?
The datasheet gives a width of 18 mm; see the table above for height and depth.
04How many contacts does the A9C22512 have and how are they arranged?
The datasheet lists 2 NO. Check that this arrangement matches your control circuit before ordering.
05How is the A9C22512 mounted?
The datasheet gives: 35 mm symmetrical DIN rail.