Schneider Electric GVAD0101 TeSys GV2/GV3 2 NC Contact Block
Description
GVAD0101: discontinued 2 NC side contact block for GV2 and GV3
The GVAD0101 is a Schneider Electric add-on auxiliary contact block for the TeSys Deca GV2 and GV3 motor circuit-breakers. The datasheet title describes it as one fault-signalling normally closed contact plus one normally closed contact, mounted on the side, for GV2 and GV3 except the GV3ME. Seven Star LLC supplies the GVAD0101 in Oman and the GCC as an independent supplier based in Muscat, and because the datasheet carries a discontinuation notice we position it as a spare for installed breakers.
It is the all-normally-closed version of the GVAD family: both contacts are NC, and the one that carries the fault role is also NC. That makes it unusual, since most indication circuits want a normally open contact for a lamp. A normally closed pair fits a loop that must open when the breaker moves.
Technical specifications of the GVAD0101
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / GVAD0101 |
| Description | Product datasheet Add-on contact block,TeSys Deca Frame 2/3,1NC(fault)+1NC,side,for GV2/GV3(except GV3ME) |
| Range | TeSys; TeSys Deca |
| Device short name | GVAD |
| Product or component type | Auxiliary contact block |
| Product compatibility | GV3L; GV2P; GV2LE; GV2RT; GV2L; GV2ME; GV3P |
| Mounting location | Left side |
| Auxiliary contacts operation | Fault signal 1 NC |
| Pole contact composition | 2 NC |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14 |
| [Ue] rated operational voltage | 48 to 690 V AC; 24 to 240 V DC |
| [Ith] conventional free air thermal | 6A |
| Mechanical durability | 100000 cycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Protection type | GB2CB– circuit breaker; GG fuse 10 A |
| Rated operational power in VA | 300 VA at 48 V AC-15 – electrical durability: 100000 cycles; 414 VA at 690 V AC-15 – electrical durability: 100000 cycles |
| Rated operational power in W | 120 W at 240 V DC-13 – electrical durability: 100000 cycles; 140 W at 110 V DC-13 – electrical durability: 100000 cycles |
| Height | 89 mm |
| Width | 9.3 mm |
| Depth | 66 mm |
| Net weight | 0.055 kg |
| Environmental characteristic | Normal environment |
| Product certifications | UKCA |
Lifecycle status of the GVAD0101
The datasheet header states Discontinued on 17 Jul 2023. Anyone who maintains panels built before that date should treat this reference as end-of-range: stocks are finite, and a replacement plan should be written down before the last breaker with this accessory fails.
The practical rule is simple. If the panel already has a GVAD0101, a like-for-like spare keeps the control wiring unchanged. If the panel is new, the active siblings in the same family, such as the GVAD0110, GVAD1001 and GVAD1010, are the sensible starting point, and we can compare the contact patterns with you.
Which breakers accept the GVAD0101
The datasheet compatibility list names the GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV3L and GV3P families, while the title excludes the GV3ME. The block sits on the left flank of the breaker, so the left side must be free of another accessory.
Because the block is only 9.3 mm wide, it adds very little to the footprint of a breaker row. This is why add-on contacts of this style are chosen for compact motor starter feeders.
The block mounts on the left side of the breaker and is 9.3 mm wide, 89 mm high and 66 mm deep, with a net weight of 0.055 kg. The datasheet lists a rated operational voltage of 48 to 690 V AC and 24 to 240 V DC, a conventional thermal current of 6 A, and 2.5 A for the fault-signalling contact. Rated operational power at AC-15 is 720 VA at 230 to 240 V and 850 VA at 380 to 415 V, each with an electrical durability of 100000 cycles; the DC-13 figures include 120 W at 240 V DC.
GVAD0101 checks before ordering
- Confirm the contact pattern: 2 NC, with one of them the fault-signal contact.
- Confirm the breaker model is on the compatibility list and is not a GV3ME.
- Confirm that the signalling circuit stays inside 6 A thermal and 2.5 A fault limits.
- Ask whether the installed breaker is itself still current, since spare accessories are of little use on a stranded breaker.
- Check the minimum switching level: the datasheet gives 5 mA and 17 V for reliable operation.
Fitting and testing the GVAD0101 on site
Switch the breaker off and isolate the feeder first. The block clips to the side of the device and its terminals face the wiring duct, so a labelled ferrule on each wire helps later fault-finding.
After fitting, test both states: close the breaker, confirm the NC pair opens as the circuit requires, then trip it with the test method of the breaker and confirm the fault contact changes state. The mechanical durability is 100000 cycles, so a block that has been through many trip tests deserves attention.
GVAD0101 in Oman and GCC plants
Older motor starter panels at water pumping stations, desalination plants and industrial utilities often still carry GV2 breakers with this class of block. A failed contact block can leave a PLC reading a permanent fault, and a spare on the shelf is the quickest cure.
In dusty or hot panels, check the terminals at each planned shutdown, since screw terminals on auxiliary circuits are easy to forget.
GVAD family: the GVAD0101 against its siblings
The four references below share the same left-side mounting and ratings and differ only in contact pattern and lifecycle status.
| Reference | Contacts | Fault signal contact | Status in datasheet |
|---|---|---|---|
| GVAD0101 | 2 NC | Fault signal 1 NC | Discontinued (17 Jul 2023) |
| GVAD0110 | 1 NO + 1 NC | Fault signal 1 NC | Listed |
| GVAD1001 | 1 NO + 1 NC | Fault signal 1 NO | Listed |
| GVAD1010 | 2 NO | Fault signal 1 NO | Listed |
Information to send with an RFQ for the GVAD0101
- Full reference and quantity required
- Breaker model (GV2 or GV3 type) the block must fit
- Contact logic needed (NO or NC fault signal)
- Signal voltage and the input card that reads it
- Delivery location and timing
Documents and quotation
A datasheet for the GVAD0101 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.
Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric GVAD0101 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric GVAD0101 TeSys GV2/GV3 2 NC
Answers from our engineering team on installation, compatibility and integration.
01Is the GVAD0101 still in production?
The datasheet shows it as discontinued on 17 Jul 2023, so it should be treated as a spare for installed equipment.
02Which breakers does the GVAD0101 fit?
The datasheet lists GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV3L and GV3P; the title says except GV3ME.
03How many contacts does the GVAD0101 have?
Two normally closed contacts, one of them the fault-signal contact.
04Which side does the GVAD0101 mount on?
The left side of the breaker. Follow the installation guide for clearances and tightening torques.
05What are the size and weight of the GVAD0101?
9.3 mm wide, 89 mm high, 66 mm deep, 0.055 kg.