Schneider Electric LRE14 EasyPact TVS 7-10 A Overload Relay
Description
What the LRE14 protects, in plain terms
The LRE14 is a Schneider Electric product listed in its datasheet as: EasyPact TVS differential thermal overload relay 7…10 A – class 10A. It is the thermal overload part of a motor starter: it follows the current drawn by the motor and opens a signalling contact when an overload or a lost phase would otherwise overheat the windings. Seven Star LLC supplies the LRE14 in Oman and the GCC as an independent supplier based in Muscat.
The reference tells you the family and the band. LRE is the device short name given in the datasheet, the range is Easy TeSys Protect, and the title states the adjustable window, 7 to 10 A, together with trip class 10A. The two or three digits after LRE are the range code of that band. The LRE14 is built on the compact body (45 mm wide) for LC1E contactors up to the LC1E38 size. The 7 to 10 A window is a very common band, because a lot of small pumps, fans, compressors and conveyors draw somewhere between 7 and 10 A.
LRE14 datasheet values at a glance
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LRE14 |
| Description | EasyPact TVS differential thermal overload relay 7…10 A – class 10A |
| Range | Easy TeSys; Easy TeSys Protect |
| Relay application | Motor protection |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 7 to 10 A |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
| Network / frequency | AC / 50…60 Hz |
| Rated operational voltage [Ue] | ≤ 690 V AC |
| Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 |
| Auxiliary contacts | 1 NO + 1 NC |
| Signalling circuit thermal current [Ith] | 5 A for signalling circuit |
| Associated fuses | 20 A gG or 12 A aM (power circuit); 5 A gG (signalling circuit) |
| Product compatibility | LC1E09 to LC1E38 |
| Mounting | Under contactor; Plate, with specific accessories; Rail, with specific accessories |
| Power terminals | Screw clamp, flexible cable without ferrule 1.5 to 6 mm² |
| Tightening torque | Power circuit: 1.7 N.m – on screw clamp terminals; Signalling circuit: 1.7 N.m – on screw clamp terminals |
| Dimensions (W x H x D) | 45 mm x 44.5 mm x 70 mm |
| Net weight | 0.13 kg |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient temperature, operation | -20 to 60 °C without derating conforming to IEC 60947-4-1; -20 to 70 °C with derating |
| Ambient temperature, storage | -60 to 80 °C |
| Product certifications | CB Scheme; CCC; CE; EAC |
Fitting the LRE14 to a contactor
The datasheet lists the compatible contactors for the LRE14 as LC1E09 to LC1E38. Mounting options are listed as under contactor; plate, with specific accessories; rail, with specific accessories. In a normal starter the relay plugs directly under the contactor, which keeps the power wiring short and gives a compact direct-on-line starter without extra links.
The body measures 45 mm wide, 44.5 mm high and 70 mm deep with a net weight of 0.13 kg; the packed unit weighs 148 g. A nameplate current of 10 A sits at the top of this dial and at the bottom of the 9 to 13 A relay; decide which gives the more comfortable middle-of-scale setting.
Typical uses in Oman and the GCC
Starters of this type are found in water and desalination auxiliaries, oil and gas utility skids, power station balance-of-plant and building services across Oman and the GCC. The 7 to 10 A window is a very common band, because a lot of small pumps, fans, compressors and conveyors draw somewhere between 7 and 10 A..
Heat and dust are the practical enemies. The datasheet allows -20 to 60 °C without derating conforming to IEC 60947-4-1 without derating and IP20 protection, so the LRE14 belongs inside a closed, ventilated panel; in summer the inside of a sunlit enclosure can be far above the outdoor mean, so compare your measured panel temperature with that limit.
How the LRE14 trips: threshold, phase loss and class
The dial of the LRE14 spans 7 to 10 A. The datasheet states a tripping threshold of 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1, so the relay is designed to act when the motor current reaches about 1.14 times the dialled value, with a tolerance of 0.06 times. At the top of the scale that is roughly 11.4 A and at the bottom roughly 7.98 A.
It is a differential relay, which matters on a three-phase motor. The datasheet gives a tripping current of 130 % of Ir on two phases while the third phase is at zero, conforming to IEC 60947-4-1; at the top of the dial 10 A that corresponds to about 13 A in each of the two live phases. A broken fuse or loose terminal therefore does not leave the motor running single-phased unnoticed.
Class 10A is the fast characteristic for motors that start quickly; the class number is the longest tripping time in seconds at 7.2 times the setting current under IEC 60947-4-1. Temperature compensation is listed over -20 to 60 °C, so the setting does not wander with panel temperature inside that band.
Before you order the LRE14
- Motor nameplate current inside 7 to 10 A, ideally near the middle of the dial.
- Contactor in the starter must be one of LC1E09 to LC1E38.
- Class 10A: confirm that the load starts quickly enough for this characteristic.
- Upstream short-circuit device: 20 A gG or 12 A aM, per the datasheet.
- Space: allow 45 mm x 44.5 mm x 70 mm and 0.13 kg.
- Say whether the relay is for a new starter or replaces one that has tripped out of service.
Neighbouring ranges around the LRE14
The table places the LRE14 between its nearest neighbours in this group, using the datasheet values of each. It helps when the nameplate current sits near a boundary or when the contactor decides the frame.
| Reference | Setting range | Listed contactors | Power fuse | Width x height x depth |
|---|---|---|---|---|
| LRE12 | 5.5 to 8 A | LC1E09 to LC1E38 | 20 A gG | 45 mm x 44.5 mm x 70 mm |
| LRE14 | 7 to 10 A | LC1E09 to LC1E38 | 20 A gG | 45 mm x 44.5 mm x 70 mm |
| LRE16 | 9 to 13 A | LC1E12 to LC1E38 | 25 A gG | 45 mm x 44.5 mm x 70 mm |
Commissioning, reset and spares
Set the dial of the LRE14 to the nameplate current of the motor, not to the contactor rating. Use the red stop push-button to confirm the contactor drops and the green reset push-button to restore the relay afterwards. After any short-circuit event inspect the relay and starter, because the overload relay does not replace the upstream fuse or breaker.
For spares keep the same reference instead of choosing by range alone, since the compatible contactor list differs from band to band (LC1E09 to LC1E38 for the LRE14). If you are unsure, send the contactor reference and the motor nameplate current and we will confirm the matching member of the family.
Information to send with an RFQ for the LRE14
- Full reference LRE14 and the quantity required
- Motor nameplate current, voltage and power
- Contactor reference the relay will be fitted to
- Delivery location and timing
- New starter, replacement or spare
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Lre Compact Range
Seven Star LLC supplies models from the Se Lre Compact range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LRE01 EasyPact TVS 0.1-0.16 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE02 EasyPact TVS 0.16-0.25 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE03 EasyPact TVS 0.25-0.4 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE04 EasyPact TVS 0.4-0.63 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE10 EasyPact TVS 4-6 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE12 EasyPact TVS 5.5-8 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE14 EasyPact TVS 7-10 A Overload Relay | Contactors & Overload Relays | You are viewing this model |
| Schneider Electric LRE21 EasyPact TVS 12-18 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRE22 EasyPact TVS 16-24 A Overload Relay | Contactors & Overload Relays | View details |
Datasheets & Documents
- Datasheet Schneider Electric LRE14 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LRE14 EasyPact TVS 7-10 A
Answers from our engineering team on installation, compatibility and integration.
01What current range does the LRE14 cover?
The datasheet gives a thermal protection adjustment range of 7 to 10 A with class 10A tripping. The motor nameplate current should fall inside that window.
02Which contactors can the LRE14 be mounted on?
The datasheet lists LC1E09 to LC1E38. The relay mounts under the contactor, and it can also be used on a plate or rail with specific accessories.
03How does the LRE14 react to a lost phase?
It is a differential relay. The datasheet states a tripping current of 130 % of Ir on two phases with the third at zero, in addition to the 1.14 +/- 0.06 Ir overload threshold.
04Which fuses does the datasheet associate with the LRE14?
For the power circuit it names 20 A gG or 12 A aM, and for the signalling circuit 5 A gG. These protect against short circuits; the relay itself handles overload.
05What are the size and contact arrangement of the LRE14?
The datasheet gives 45 mm wide, 44.5 mm high, 70 mm deep and a net weight of 0.13 kg, with one normally open and one normally closed auxiliary contact.