Schneider Electric A9C20868 iCT 63 A 2NO+2NC 220-240 V Contactor

Description

A9C20868: 63 A contactor with two NO and two NC poles

The A9C20868 is a Schneider Electric Acti9 contactor listed in the datasheet as: iCT 63A 2NO+2NC 220 to 240V 50Hz contactor. The A9C20868 combines the 63 A frame with a split contact set of two normally open and two normally closed poles. One coil therefore connects two circuits and, at the same moment, disconnects two others, which is useful for changeover duty at the higher current level. Seven Star LLC supplies the A9C20868 in Oman and the GCC as an independent supplier based in Muscat.

Decoding: A9C family, 63 A, four poles arranged 2 NO + 2 NC, coil 220 to 240 V AC 50 Hz. The datasheet lists 63 A AC-7A and 20 A AC-7B, so, unlike the all-NO 63 A reference A9C20864, this one does give a motor-type category figure.

Technical specifications of the A9C20868

Parameter Specification
Manufacturer / part number Schneider Electric / A9C20868
Description iCT 63A 2NO+2NC 220 to 240V 50Hz contactor
Range of product Acti9
Product name Acti9 iCT
Product or component type Contactor
Device short name iCT
Device application Motor-heating-lighting
Poles 4P
[Ie] rated operational current 63 A AC-7A; 20 A AC-7B
Pole contact composition 2 NO + 2 NC
Network type AC
Control type Remote control
[Uc] control circuit voltage 220 to 240 V AC 50 Hz
Network frequency 50 Hz
[Ue] rated operational voltage 400 V AC 50 Hz
Maximum power 2.1 W at 400 V AC
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand 4 kV
Control signal type Maintained
Switching frequency 100 switching operations/day
Local signalling Action indicator
Hold-in power consumption in VA 6.5 VA
Inrush power in VA 53 VA
Mounting mode Clip-on
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 60 mm
Mechanical durability 1000000 cycles
Electrical durability 100000 cycles IEC/EN 61095 63 A 50 Hz AC-7A; 30000 cycles IEC/EN 61095 20 A 50 Hz AC-7B; 30000 cycles IEC/EN 61095 50 Hz AC-7C
Tightening torque Control circuit: 0.8 N.m; Power circuit: 3.5 N.m
Market segment Small commercial; Residential
Standards IEC/EN 61095
Noise level 30 dB
IP degree of protection IP20
Relative humidity 95 % at 55 °C
Operating altitude 2000 m
Ambient air temperature, operation -5 to 60 °C
Ambient air temperature, storage -40 to 70 °C

Power circuit and coil data of the A9C20868

The rated operational current is 63 A AC-7A; 20 A AC-7B. Rated operational voltage: 400 V AC 50 Hz. Maximum power figure: 2.1 W at 400 V AC. Coil voltage: 220 to 240 V AC 50 Hz. Hold-in consumption: 6.5 VA. Inrush consumption: 53 VA. Rated insulation voltage: 500 V AC 50/60 Hz. Rated impulse withstand voltage: 4 kV. Mechanical durability: 1000000 cycles.

With the coil energised, the NO contacts close and the NC contacts open, so a supply can be moved from one circuit to another with a single command. At 63 A this is the frame used when two feeders, for example a mains supply and an alternative one, must never be connected together; the mechanical movement of one contact block does the interlocking.

AC-7A and AC-7B ratings of the A9C20868: reading the load categories

It helps to read the datasheet current as a category-specific figure. The A9C family is built for building and light-commercial installations, so its categories refer to household-type duty. If a load is an ordinary resistive element, the AC-7A value applies; if it is a small appliance motor, the AC-7B value applies; if it is a heavy motor, a different product is correct.

Electrical durability in the datasheet: 100000 cycles IEC/EN 61095 63 A 50 Hz AC-7A; 30000 cycles IEC/EN 61095 20 A 50 Hz AC-7B; 30000 cycles IEC/EN 61095 50 Hz AC-7C.

How the A9C20868 compares with neighbouring iCT contactors

The A9C20864 differs in contacts 4 NO against 2 NO + 2 NC here; current 63 A AC-7A against 63 A AC-7A here. The A9C22512 differs in poles 2P against 4P here; contacts 2 NO against 2 NO + 2 NC here; coil 220 V AC 50 Hz against 220 to 240 V AC 50 Hz here; current 16 A AC-7A against 63 A AC-7A here; width 18 mm against 54 mm here.

The table below lists the iCT references of this group with their main differences so that a purchase order can be checked against the family.

Reference Poles / contacts Rated current Coil Width
A9C20731 1P / 1 NO 25 A AC-7A, 8.5 A AC-7B 230 to 240 V AC 50 Hz 18 mm
A9C20732 2P / 2 NO 25 A AC-7A, 8.5 A AC-7B 230 to 240 V AC 50 Hz 18 mm
A9C20834 4P / 4 NO 25 A AC-7A, 8.5 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20838 4P / 2 NO + 2 NC 25 A AC-7A, 8.5 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20842 2P / 2 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 36 mm
A9C20843 3P / 3 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C20844 4P / 4 NO 40 A AC-7A, 15 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C20864 4P / 4 NO 63 A AC-7A 220 to 240 V AC 50 Hz 54 mm
A9C20868 (this page) 4P / 2 NO + 2 NC 63 A AC-7A, 20 A AC-7B 220 to 240 V AC 50 Hz 54 mm
A9C22512 2P / 2 NO 16 A AC-7A, 6 A AC-7B 220 V AC 50 Hz 18 mm

Selection checklist for the A9C20868

  • Count the number of contacts needed in each state; this reference gives exactly two NO and two NC.
  • Check the 20 A AC-7B figure if a small motor-type load is in the circuit.
  • Match coil voltage and frequency to the control supply; this reference uses 220 to 240 V AC 50 Hz.
  • Check the width of 54 mm (6 pitches) against free rail space and spare gaps for heat.
  • Confirm the number of operations per day stays within the datasheet figure.

Mounting, wiring and maintenance of the A9C20868

Maintenance is mostly visual: check terminals for discolouration, re-torque after the first weeks of load cycles, and listen for coil hum, which the datasheet puts at 30 dB noise level. A loud buzz usually means an under-voltage coil or a dirty pole face. In dusty coastal sites an enclosure with filters or sealing helps, because the device is protected to IP20 only.

The datasheet lists the environment as -5 to 60 °C in operation and -40 to 70 °C in storage, relative humidity of 95 % at 55 °C, an altitude limit of 2000 m and pollution degree 2.

Where the A9C20868 is used in Oman and the GCC

Typical duty is source changeover for heating or lighting loads, where an auxiliary circuit must drop when the main one pulls in. Hotels and clinics in the Gulf use such schemes for non-essential load shedding when a generator takes over.

Because the NC contacts carry the same 63 A rating as the NO contacts in this frame, the load that stays connected when the coil is de-energised is a real continuous load; check temperature rise in the board when the contactor is held open for long periods without the coil energised, and allow the usual spacing.

Information to send with an RFQ for the A9C20868

  • Full reference (A9C20868) and quantity required
  • Supply and control voltage at site, with the frequency
  • Existing panel, rail and neighbouring devices it must fit beside
  • Delivery location and timing
  • Whether it is a spare, a like-for-like replacement or a new installation
  • Load type and current: lighting, heating or motor-type

Documents and quotation

A datasheet for the A9C20868 is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it should be read together with the manufacturer’s installation instructions for the final design.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Acti9 Ict Range

Seven Star LLC supplies models from the Se Acti9 Ict range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric A9C20731 iCT 25 A 1NO 230-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20732 iCT 25 A 2NO 230-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20834 iCT 25 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20838 iCT 25 A 2NO+2NC 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20842 iCT 40 A 2NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20843 iCT 40 A 3NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20844 iCT 40 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20864 iCT 63 A 4NO 220-240 V ContactorContactors & Overload RelaysView details
Schneider Electric A9C20868 iCT 63 A 2NO+2NC 220-240 V ContactorContactors & Overload RelaysYou are viewing this model
Schneider Electric A9C22512 iCT 16 A 2NO 220 V ContactorContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric A9C20868 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9C20868 iCT 63 A 2NO+2NC

Answers from our engineering team on installation, compatibility and integration.

01What are the dimensions of the A9C20868?
The datasheet gives a width of 54 mm; see the table above for height and depth.
02How many contacts does the A9C20868 have and how are they arranged?
The datasheet lists 2 NO + 2 NC. Check that this arrangement matches your control circuit before ordering.
03How is the A9C20868 mounted?
The datasheet gives: 35 mm symmetrical DIN rail.
04What ambient temperature range is listed for the A9C20868?
The datasheet lists -5 to 60 °C in operation and -40 to 70 °C in storage. In hot Gulf plant rooms the operating upper limit should be compared with the real panel temperature.
05What ingress protection does the A9C20868 have?
The datasheet states IP20, so it belongs inside a closed enclosure.