- Automation & ControlView all 1,938 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Industrial Computers
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric LC1D09U7 TeSys Deca 9 A Contactor 240 V AC
Description
LC1D09U7: 9 A TeSys Deca contactor with 240 V AC coil
The LC1D09U7 is a Schneider Electric TeSys Deca contactor listed in the datasheet as: TeSys D contactor – 3P(3 NO) – AC-3 – ≤ 440 V 9 A – 240 V AC coil. The LC1D09 is the smallest frame of the TeSys Deca contactor family, rated 9 A in AC-3 at up to 440 V. It is built for small three-phase motors, solenoid and resistive loads, and for control-duty switching where panel space is limited. The same 45 mm wide body takes the larger 12, 18 and 25 A ratings, so cabinet layouts stay uniform. Seven Star LLC supplies the LC1D09U7 in Oman and the GCC as an independent supplier based in Muscat.
Decoding the reference from the datasheet title: LC1D is the three-pole TeSys Deca contactor, 09 is the 9 A frame, and U7 is the control voltage code, here a 240 V AC 50/60 Hz coil. The datasheet gives dimensions of 77 x 45 x 86 mm (H x W x D) and a net weight of 0.32 kg.
Technical specifications of the LC1D09U7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LC1D09U7 |
| Description | TeSys D contactor – 3P(3 NO) – AC-3 – ≤ 440 V 9 A – 240 V AC coil |
| Range of product | TeSys Deca Advanced |
| Device short name | LC1D |
| Product or component type | Contactor |
| Contactor application | Motor control; resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles / contact composition | 3P; 3 NO |
| Rated operational voltage [Ue] | Power circuit: up to 690 V AC (25 to 400 Hz); up to 300 V DC |
| Rated operational current [Ie] | 9 A at <60 °C at up to 440 V AC (AC-3 and AC-3e); 25 A in AC-1 |
| Control circuit voltage [Uc] | 240 V AC 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Inrush / hold-in power | 70 VA inrush; 7 VA (50 Hz) and 7.5 VA (60 Hz) hold-in |
| Motor power (AC-3), 400 V | 4 kW at 380/400 V |
| Motor power, 60 Hz | 5 hp at 460/480 V |
| Conventional free-air thermal current | 25 A at 60 °C |
| Rated making / breaking capacity | 250 A at 440 V |
| Associated fuse rating | 25 A gG (type 1) and 20 A gG (type 2) at up to 690 V |
| Auxiliary contacts | 1 NO + 1 NC, mechanically linked; NC mirror contact |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 2 Mcycles at 9 A AC-3; 0.6 Mcycles at 25 A AC-1 |
| Maximum operating rate | 3600 cycles per hour at 60 °C |
| Operating time | 12 to 22 ms closing; 4 to 19 ms opening |
| Power terminals | 1 to 4 mm² per terminal flexible without ferrule, 1 to 2.5 mm² per terminal with two ferruled conductors |
| Tightening torque (power) | 1.7 N.m |
| Mounting support | Rail; plate |
| IP degree of protection | IP20 front face (IEC 60529) |
| Ambient temperature | -40 to 60 °C; 60 to 70 °C with derating |
| Operating altitude | 0 to 3000 m |
| Dimensions (H x W x D) | 77 x 45 x 86 mm |
| Net weight | 0.32 kg |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
Ratings of the LC1D09U7 in motor and resistive duty
At 9 A AC-3 the datasheet lists 2.2 kW at 220/230 V, 4 kW at 380/400 V and 415/440 V and 5.5 kW at 500 V and 660/690 V, plus 5 hp at 460/480 V for three-phase motors. On resistive loads, AC-1, the contactor handles 25 A at 440 V.
| Supply voltage (AC-3) | Motor power |
|---|---|
| 220/230 V | 2.2 kW |
| 380/400 V | 4 kW |
| 415/440 V | 4 kW |
| 500 V | 5.5 kW |
| 660/690 V | 5.5 kW |
Those motor ratings apply to AC-3 and AC-3e starting at up to 440 V; for AC-4 (plugging and inching) the datasheet gives a reduced figure, so a repetitive-reversing duty needs its own check. For the Omani and GCC 415 V network, the 380/400 V and 415/440 V rows are the relevant ones. Power circuit insulation is rated 690 V with an impulse withstand of 6 kV, overvoltage category III and pollution degree 3.
The 240 V AC coil on the LC1D09U7
The coil of the LC1D09U7 is rated 240 V AC 50/60 Hz. The datasheet gives an inrush of 70 VA (cos phi 0.75, at 20 °C) and a hold-in of 7 VA at 50 Hz and 7.5 VA at 60 Hz (cos phi 0.3). Dividing by the coil voltage, that is roughly 0.29 A at the moment of closing and 0.03 A while held in at 50 Hz; these are our own calculations from the VA figures and are only an order-of-magnitude guide for sizing control fuses and transformers. The coil has no built-in suppressor module, so a surge suppressor or RC network is an add-on if the coil is switched by a PLC output or a small relay. Control circuit voltage limits per the datasheet: drop-out between 0.3 and 0.6 Uc, operational at 0.8 to 1.1 Uc at 50 Hz and 0.85 to 1.1 Uc at 60 Hz in the range from -40 to 60 °C, and 1 to 1.1 Uc between 60 and 70 °C. A 240 V AC coil is matched to the nominal single-phase voltage of the Omani network, so it connects directly to a phase and neutral without a control transformer. This keeps small starter panels simple: one fused supply, one stop button, one start button, and the coil.
Wiring a 240 V AC coil: it connects directly to the phase and neutral of the Omani 240 V supply, so a small starter needs no control transformer. A single fused feed can supply the stop button, the start button, the overload contact and the coil in series, which keeps the panel simple and inexpensive to wire.
Commissioning check on a 240 V AC coil: measure the control supply at the coil and confirm it stays in the 192 V to 264 V window (0.8 to 1.1 Uc) with all loads on. If a feeder is long or heavily loaded, the lower end of that window is the one that matters at motor start, when many coils can drop out together.
Typical homes for the LC1D09U7: locally built starter panels, small water-transfer pump sets, ventilation fans and compressor controls where the local network is 240 V single-phase for control. It is also a sensible choice for a machine arriving with a nameplate of 240 V.
Contacts, terminals and service life of the LC1D09U7
The power terminals are open screw clamps taking 1 to 4 mm² flexible conductors, and the datasheet gives a tightening torque of 1.7 N.m. It carries one NO and one NC auxiliary contact, mechanically linked, with the NC also acting as a mirror contact for safety circuits.
Mechanical life is 15 million operations; at 9 A AC-3 the electrical life is 2 million, and 0.6 million at 25 A AC-1. With a 3600 operations per hour maximum rate at 60 °C, the 9 A frame suits frequent-start duties such as small conveyors and dosing pumps.
The LC1D09U7 within the LC1D09 range
All references below share the 9 A power section and differ in coil voltage. The datasheet data for ratings, terminals and endurance are the same across them; only the coil voltage changes. Against its neighbours, the 240 V AC coil is the one that matches the nominal supply of the Omani network, so no tapping or transformer is needed. The 230 V version also works on most 240 V supplies because of its window, but the 240 V coil sits closer to the middle of its range at local voltage.
| Part number | Coil voltage | Note |
|---|---|---|
| LC1D09U7 | 240 V AC | This page |
Choosing the LC1D09U7: a checklist
- Motor power (up to 4 kW at 400 V in AC-3) and its full-load current at the supply voltage.
- Utilisation category: AC-3 for squirrel-cage starting, AC-1 for resistive loads up to 25 A, AC-4 only with the reduced rating.
- Coil voltage and whether the control supply is AC (this reference) or DC.
- Overload protection: thermal overload relay or motor circuit breaker that matches the 9 A frame.
- Auxiliary contact needs beyond the built-in 1 NO + 1 NC.
- Check that the control supply is nominally 240 V (not 230 V), and that the contactor coil label in the existing starter matches.
- Confirm the control supply really is 240 V AC before ordering the LC1D09U7; coil voltage cannot be changed on the contactor.
Where the LC1D09U7 works in Oman and the GCC
A 9 A contactor typically drives small circulation pumps, fan units, dosing and chemical metering pumps, roller shutters and gate motors, plus heater elements in HVAC equipment. In the Gulf it is common in packaged equipment shipped from OEMs, where the smallest frame is chosen to keep panels compact.
The 240 V AC coil matches the nominal single-phase supply of the Omani network and is easy to use in locally built starter panels. Ambient temperatures inside outdoor panels in Oman often exceed the 60 °C limit for full rating in summer; the datasheet allows operation to 70 °C with derating, but the usual practice is to shade, ventilate or air-condition the enclosure. Fine dust and humid coastal air call for sealed enclosures because the contactor itself is only IP20 on the front face.
Information to send with an RFQ for the LC1D09U7
- The reference LC1D09U7 and the quantity required
- Whether it replaces an existing LC1D09 contactor and the coil voltage printed on it
- Motor power, supply voltage and starting method (direct-on-line, reversing, star-delta)
- Number of auxiliary contacts and overload relay that will be fitted
- Delivery location in Oman or the GCC and the timing needed
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number LC1D09U7, the quantity and the application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric LC1D09U7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LC1D09U7 TeSys Deca 9 A
Answers from our engineering team on installation, compatibility and integration.
01What is the AC-3 current rating of the LC1D09U7?
The datasheet lists 9 A at up to 440 V (AC-3 and AC-3e) and 25 A in AC-1.
02What coil voltage does the LC1D09U7 use?
The control circuit voltage is 240 V AC 50/60 Hz, a coil without a built-in suppressor module.
03How large a motor can the LC1D09U7 start at 400 V?
The datasheet gives 4 kW at 380/400 V in AC-3, and 5 hp at 460/480 V for three-phase 60 Hz motors.
04What are the dimensions and weight of the LC1D09U7?
The datasheet lists 77 x 45 x 86 mm (H x W x D) and a net weight of 0.32 kg.
05Does the LC1D09U7 include auxiliary contacts?
The datasheet lists an auxiliary contact composition of 1 NO + 1 NC, mechanically linked, with the NC acting as a mirror contact.


















Reviews
There are no reviews yet.