- Automation & ControlView all 2,674 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Motor Soft Starters
- Safety Switches & Guard Locking
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: IMI STI
IMI STI SAR Snap Acting Relay
Description
IMI STI SAR overview
The IMI STI SAR snap acting relay from IMI STI is a narrow-band pneumatic controller with an adjustable set point. Pressure in the input chamber opposes the load on an adjusting spring. When the input pressure exceeds the spring setting, the input signal seat closes and the open supply seat passes full supply pressure straight to the output. When the input pressure is below the setting, the supply seat closes and the signal seat opens, so the output equals the signal.
It is generally used on the input signal of pneumatically controlled positioners, giving a precise switching pressure and low hysteresis.
Buyers searching for the IMI STI SAR are usually replacing a unit on an existing valve package or extending a project that already uses IMI STI equipment, so matching the exact designation shown on the nameplate is the safest route to a correct quotation.
Key features of the SAR
- Compact design in anodised aluminium
- Lockable adjusting screw with a safety design
- Precise switching pressure and low hysteresis
- Suitable for standard, offshore, sandstorm and copper free ambient conditions
- Single and double acting actuators
- Low and high ambient temperature execution
SAR technical specifications
The table below lists the data for the SAR taken from the manufacturer’s published documents. Values that are not stated by the manufacturer are left out on purpose.
| Function | Narrow-band pneumatic snap acting relay with adjustable set point |
|---|---|
| Housing material | Anodised aluminium |
| Pilot signal connection | 1/8 inch NPT |
| Feeding connections | 1/4 inch NPT |
| Output connections | 1/4 inch NPT |
| Operating pressure | Minimum 1.4 bar, maximum 2.5 bar (design pressure 10 bar) |
| Operating temperature | -20 to 70 degC |
| Weight | 4 kg |
Temperature and ambient variants are available on request according to the manufacturer.
Typical applications in oil and gas, utilities, water and manufacturing
Power and desalination plants use the SAR where reliable control or safety stroking is needed on steam, feedwater, bypass and cooling circuits. Utilities and water treatment operators also use this type of equipment for dampers, control valves and isolation valves driven by instrument air, and the SAR helps maintenance teams keep like-for-like replacements on the shelf.
In oil and gas facilities in Oman and across the GCC, the SAR is typically found on pneumatic control loops where a positioner input signal needs a definite snap switching action. Pneumatic accessories decide how fast and how stably an actuator strokes, so they are specified together with the actuator and positioner. Production, gathering and processing sites in the desert and offshore installations value equipment whose behaviour is well documented and whose spare parts can be identified by a clear part number.
Refineries, petrochemical units and general manufacturing plants apply the SAR to pneumatic control loops where a positioner input signal needs a definite snap switching action. Because the exact configuration affects performance, engineers normally confirm the supply pressure, temperature range and connection arrangement against the nameplate of the existing equipment before ordering.
Selection and compatibility notes for the SAR
When selecting the SAR, start from the actuator or valve it will serve and from the control signal and supply available on site. Temperature and ambient variants are available on request according to the manufacturer.
Check the supply medium and pressure, the ambient temperature range and any hazardous-area requirement before ordering the SAR. If a certificate or approval is needed for the installation in Oman or elsewhere in the GCC, state it in the request so that it can be checked against the manufacturer’s documents rather than assumed.
Installation and commissioning of the SAR
Install the SAR in the pneumatic circuit in the position shown in the manufacturer’s drawing, use clean instrument air, and check every connection for leaks. Adjust any setting screw in small steps and confirm the result with actual stroking times before locking the setting.
Record the model code, the part number and the final settings of the SAR on the commissioning sheet so that future maintenance and any reorder can refer to the same data.
Maintenance and service for the SAR
When a unit fails, identify the exact model code and part number from the nameplate before ordering a replacement. For the SAR this removes the risk of receiving a body with a different size, material or temperature range.
Plan periodic inspection of the SAR according to the instruction manual of the manufacturer. Typical checks are leakage at joints, condition of the air supply, mechanical wear or contamination, and confirmation that the setting still gives the required response.
Poor air quality is the most common cause of pneumatic accessory problems, so keep filter regulators and dryers serviced upstream of the SAR. Replace elastomer parts only with the materials specified for the application, and do not modify the unit in the field.
Related products and ordering notes for the SAR
Items that are commonly specified together with the SAR include: CRP-3/M, SA-1, UP-2, SR/CCK, MC motion converter. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; product names and part numbers are used only to identify the items offered.
Lead times, availability and alternatives depend on the stock position at the time of the request. If the SAR is not the exact configuration needed, send the nameplate data and we will suggest the closest match from the manufacturer’s published model selection.
SAR frequently asked questions
What does the SAR do? It switches its output between supply pressure and the input signal depending on whether the input pressure is above or below an adjustable spring setting.
What pilot connection does it use? The pilot signal connection is 1/8 inch NPT, with 1/4 inch NPT feeding and output connections.
What is its operating pressure range? The brochure lists 1.4 bar minimum and 2.5 bar maximum, with a design pressure of 10 bar.
Can the setting be locked? Yes, the unit has a lockable adjusting screw with a safety design.
How do I request a quotation for the SAR? Send the part number SAR with quantity to Seven Star LLC and we will reply to your RFQ.
Documents and quotation
The manufacturer’s datasheet for the SAR is available from Seven Star LLC on request and is listed on this page for download. It should be read together with the nameplate data of the installed equipment.
To request a quotation, send an RFQ with the part number SAR, the quantity, the required delivery location in Oman or the GCC, and any special requirement such as certification or documentation. We will reply with availability and commercial terms.
Datasheets & Documents
- Datasheet IMI STI SAR Snap Acting Relay Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
IMI STI is an Italian manufacturer of pneumatic, hydraulic and direct-gas valve actuators, valve positioners and actuator accessories. It is based in Levate, near Bergamo, and is part of the IMI plc group (IMI Process Automation).
Seven Star LLC is an independent supplier in Muscat. We list IMI STI positioners, actuators and switches for valve automation in Oman and the GCC and source them by full model code.
IMI STI company profile
| Established | 1960, in Gorle (Bergamo), Italy |
|---|---|
| Manufacturing site | Levate (Bergamo), Italy, since 2014. The plant is about 15 km from the original Gorle site. |
| Group | IMI plc, Process Automation division. STI S.r.l. is the legal entity and IMI STI is the brand name. |
| Product families | Quarter-turn Scotch yoke actuators, linear actuators, lift-and-turn actuators, stepper actuators, valve positioners, limit switches, pressure switches and pneumatic accessories |
| Typical duty | Emergency shutdown and isolation valves, anti-surge valves, turbine bypass and steam valves, dampers and process control valves |
| Industries | Oil and gas, power, petrochemicals, process industries, water and metals |
Milestones
- 1960: STI is founded in Gorle, Bergamo.
- 2002: IMI plc acquires STI, according to the company's own literature.
- 2014: Manufacturing moves to the new plant in Levate, about 15 km from Gorle.
IMI STI product series
| Series | Type | Key published data |
|---|---|---|
| RTC | Pneumatic Scotch yoke quarter-turn actuator | Up to 12 bar supply, -30 to +100 °C ambient, 90° rotation; single-acting, double-acting or spring-return; air, nitrogen, sweet or sour gas; ISO 5211 mounting; SIL 3, ATEX, PED, IP66/67M |
| RTQ | High-torque pneumatic Scotch yoke actuator | For large ball, plug and butterfly valves in harsh environments; canted or symmetrical yoke |
| RTQD / RTQH | Direct-gas and hydraulic Scotch yoke actuators | RTQD: gas-over-oil, operating pressure up to 114 bar, -20 to +100 °C; RTQH: hydraulic version for sites with a hydraulic power supply |
| SC/V, SC | Pneumatic linear actuators | For globe and gate valves (SC/V) and for dampers (SC); SC/VLT is the lift-and-turn version |
| SHP | Smart high-performance positioner | HART 7, self-tuning, Cv up to 2.3, 2.5 to 10.5 bar supply, ATEX and IECEx, IP66 aluminium or stainless steel housing |
| SHP-SIS | Safety positioner | IEC 61508:2010 up to SIL 3, built-in partial stroke testing, -55 to +85 °C ambient |
| FasTrak FT, QuickTrak | Smart digital positioners and valve control systems | Digital positioning with valve diagnostics |
| SA/CL | Analog positioner | Analog positioner for control valve actuators |
| 2130 | Limit switch box | Position feedback for rotary valve actuators |
Scotch yoke actuators give their highest torque at the start and end of the stroke. That is where a ball, plug or butterfly valve needs the most break-out and seating torque, so a Scotch yoke can be smaller than a rack-and-pinion actuator for the same valve. A canted yoke moves the torque peak toward one end of the stroke, for valves whose highest demand is when they close. A symmetrical yoke gives the same curve in both directions.
Where IMI STI products are used
In the GCC, IMI STI actuators and positioners appear mostly on emergency shutdown (ESD) and blowdown valves, compressor anti-surge valves, steam turbine bypass valves and large dampers in oil and gas, refining, petrochemical and power plants. On shutdown valves the SHP-SIS positioner adds partial stroke testing, so the valve can be proven to move without taking the plant down.
Ordering and replacement: what we need
For an actuator, send the full model code from the nameplate, the valve type and size, required torque or thrust with safety factor, supply medium and pressure, fail position (fail-close, fail-open or fail-last), stroke time, mounting flange (ISO 5211) and stem adaptor, ambient temperature range and the hazardous-area certification required. For a positioner, send the model, actuator type, signal (4-20 mA, HART), whether partial stroke testing or a SIL rating is needed, and the cable entry thread. When a series has been superseded, we quote the successor that IMI names in its documentation and point out any differences in mounting or signal.
Facts checked against IMI Process Automation product pages and published company history, October 2026.
Browse IMI STI products by category: Valve Positioners, Valve Actuators.
FAQ
Questions about the IMI STI SAR Snap Acting Relay
Answers from our engineering team on installation, compatibility and integration.
01What does the SAR do?
It switches its output between supply pressure and the input signal depending on whether the input pressure is above or below an adjustable spring setting.
02What pilot connection does it use?
The pilot signal connection is 1/8 inch NPT, with 1/4 inch NPT feeding and output connections.
03What is its operating pressure range?
The brochure lists 1.4 bar minimum and 2.5 bar maximum, with a design pressure of 10 bar.
04Can the setting be locked?
Yes, the unit has a lockable adjusting screw with a safety design.
05How do I request a quotation for the SAR?
Send the part number SAR with quantity to Seven Star LLC and we will reply to your RFQ.