Brand: Hydac
Hydac HDA 4775-A-0750-000 Pressure Transmitter 750 psi, SAE-6
Description
Hydac HDA 4775-A-0750-000 is a precision 4 to 20 mA pressure transmitter for 0 to 750 psi, built on a stainless steel membrane with a thin-film strain-gauge cell. The process port is a 9/16-18 UNF 2A male SAE-6 thread and the plug is an EN175301-803 (DIN 43650) three-pole connector with earth, supplied with the instrument. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Overview of HDA 4775-A-0750-000
Within the HDA 4700 line, this part sits at the lower-middle of the range table of 150, 500, 750, 1000, 1500, 3000 and 5000 psi. The 750 psi span is typical for medium-pressure hydraulics such as boom lift circuits, pilot pressures and pump control loops. A cell tested to an overload of 1740 psi and a burst of 4350 psi gives the instrument more than twice its range in reserve before damage.
The 0.25 percent accuracy is twice as good as the HDA 4400 line and makes HDA 4775-A-0750-000 a sensible choice for closed-loop control rather than simple monitoring.
Because the process port is straight-threaded, the instrument seals on its O-ring, not on the thread. A used O-ring that has been compressed to a flat profile is the most frequent cause of weeping after a transmitter is re-fitted, so keep a few spare FKM rings in the toolbox. Before closing the loop, confirm that the shield of the control cable is grounded at one end only.
Key features of HDA 4775-A-0750-000
- Accuracy 0.25 percent FS, hysteresis 0.1 percent FS, repeatability 0.05 percent FS.
- Rise time 1 ms or less; long-term drift 0.1 percent FS per year.
- Temperature coefficient 0.008 percent FS per degC typical.
- Two-wire loop powered, 8 to 30 V DC.
- IP 67 with the supplied EN175301-803 connector.
- Life expectancy above 10 million full-range cycles.
Technical specifications for HDA 4775-A-0750-000
| Parameter | Value |
|---|---|
| Model code | HDA 4775-A-0750-000 |
| Material number (catalog) | 907185 |
| Measuring range | 0 to 750 psi |
| Overload pressure | 1740 psi |
| Burst pressure | 4350 psi |
| Process connection | 9/16-18 UNF 2A male (SAE 6) |
| Tightening torque | 15 lb-ft (20 N·m) |
| Output signal | 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm |
| Supply voltage | 8 to 30 V DC, ripple 5 percent or less |
| Current consumption | 25 mA or less |
| Accuracy (terminal based) | 0.25 percent FS typical and maximum at max. setting |
| Accuracy (best-fit line) | 0.15 percent FS typical, 0.25 percent maximum |
| Temperature coefficient | 0.008 percent FS per degC typical, 0.015 maximum (zero and span) |
| Non-linearity / hysteresis | 0.3 / 0.1 percent FS maximum |
| Repeatability | 0.05 percent FS |
| Rise time | 1 ms or less |
| Long-term drift | 0.1 percent FS per year typical |
| Electrical connection | EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied |
| Pins | 1 signal +, 2 signal -, 3 not connected, earth = housing |
| Protection class | IP 67 with the mating connector fitted |
| Wetted parts | Stainless steel connection; FKM seal |
| Compensated temperature | -13 to 185 degF |
| Fluid temperature | -13 to 212 degF |
| Storage temperature | -40 to 212 degF |
| Vibration | 20 g, 10 to 500 Hz |
| Life expectancy | more than 10 million cycles, 0 to 100 percent FS |
| Weight | about 145 g |
Applications in industry
The transmitter feeds PLCs and drives on hydraulic power units, test benches and mobile machinery in oil and gas service workshops, port cranes and construction equipment. Gulf plants also fit it to compressed-gas skids, since the stainless connection and FKM seal tolerate many oils and gases. It is not a hazardous-area device; for classified zones, use a flameproof HDA 4700 version.
How HDA 4775-A-0750-000 differs from other HDA 4775 ranges
Against HDA 4775-A-1000-000 the range is 750 rather than 1000 psi and the overload and burst values are 1740 and 4350 psi instead of 2900 and 7250 psi. Against 3000 and 5000 psi the overload reaches 7250 and 11600 psi. The pin layout, plug, thread and electrical data are identical; only the measuring membrane and calibration change. The 750 psi span gives the finest resolution of these four.
Selection and compatibility
Make sure the mating port is an SAE-6 straight-thread port with an O-ring face; a tapered thread will not seal. Choose the range so that normal pressure is below two thirds of 750 psi. Load resistance must stay below (UB minus 8 V) divided by 20 mA, so at 24 V DC the loop may carry up to 800 ohms.
Installation and commissioning
Fit a clean O-ring, thread in by hand and tighten to 20 N·m (15 lb-ft) on the hex only. Fit the connector so the gasket seats evenly, tighten the central screw, and connect signal plus to pin 1 and signal minus to pin 2; the earth pin joins the housing. Check 4 mA at zero pressure and 20 mA at 750 psi on HDA 4775-A-0750-000.
Maintenance
Annual comparison against a reference gauge is enough. Replace the connector gasket if the cable is changed. If the zero drifts more than 0.25 percent of full scale, exchange the unit.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Hydac HDA 4775-A-0750-000, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Hydac pressure transmitters items can be checked against the bill of materials quickly.
Frequently asked questions about HDA 4775-A-0750-000
What do the digits in HDA 4775-A-0750-000 decode to? 47 is the series, 7 is the SAE-6 9/16-18 UNF male port, 5 is the EN175301-803 connector with PE, A is the 4 to 20 mA output, 0750 is the range in psi and 000 is the standard modification.
What are the overload and burst values? 1740 psi overload and 4350 psi burst for the 750 psi range.
Is the mating connector included? Yes. The catalog notes that the mating connector is supplied with the EN175301-803 version.
What accuracy can I expect? 0.25 percent of full scale at maximum setting, with a best-fit line figure of 0.15 percent typical.
How do I enquire for HDA 4775-A-0750-000? Send an RFQ with the part number, quantity and delivery location to Seven Star LLC.
Documents and quotation
The datasheet for HDA 4775-A-0750-000 is attached to this listing. Send an RFQ with HDA 4775-A-0750-000, quantity and delivery location for availability and lead time.
Other Models in the HDA 4700 Range
Seven Star LLC supplies models from the HDA 4700 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000 psi, SAE-6 | Pressure Transmitters | View details |
| Hydac HDA 4775-A-1000-000 Pressure Transducer 1000 psi, 4-20 mA | Pressure Transmitters | View details |
| Hydac HDA 4775-A-5000-000 High-Pressure Transducer 5000 psi | Pressure Transmitters | View details |
| Hydac HDA 4775-A-0750-000 Pressure Transmitter 750 psi, SAE-6 | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Hydac HDA 4775-A-0750-000 Pressure Transmitter 750 psi, SAE-6 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac HDA 4775-A-0750-000 Pressure Transmitter 750
Answers from our engineering team on installation, compatibility and integration.
01What do the digits in HDA 4775-A-0750-000 decode to?
47 is the series, 7 is the SAE-6 9/16-18 UNF male port, 5 is the EN175301-803 connector with PE, A is the 4 to 20 mA output, 0750 is the range in psi and 000 is the standard modification.
02What are the overload and burst values?
1740 psi overload and 4350 psi burst for the 750 psi range.
03Is the mating connector included?
Yes. The catalog notes that the mating connector is supplied with the EN175301-803 version.
04What accuracy can I expect?
0.25 percent of full scale at maximum setting, with a best-fit line figure of 0.15 percent typical.
05How do I enquire for HDA 4775-A-0750-000?
Send an RFQ with the part number, quantity and delivery location to Seven Star LLC.