- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa GP10 Portable Paperless Recorder, 5.7-inch Touch Screen
Description
Yokogawa GP10 overview
The Yokogawa GP10 is the small-display portable paperless recorder of the Yokogawa GP series. It uses the same measurement engine, touch-screen operation and modular input/output structure as the panel-mount GX series, but in a portable casing that can be placed on a bench, in a plant walk-down or on a test rig.
The model name Yokogawa GP10 starts the order code. The main unit is then specified by a type code (-1 standard, up to 100 measurement channels), a display language code E, a power supply code (1 for 100 V AC or 240 V AC, 2 for 12 V DC), a power cord code (D UL/CSA, F VDE, R AS, Q BS, H GB, N NBR, or W screw terminal without cord) and optional features. These power and cord codes are what separates a GP10 order from a GX10 order, and they are easy to get wrong for a GCC destination.
This page describes the GP10 as published in the manufacturer’s general specification GS 04L52B01, written in our own words for buyers who need to identify the exact part. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We supply against the part number you provide and do not substitute without your written agreement.
Key features of the GP10
- Touch-screen operation with flick, pinch-in and pinch-out gestures, and a trend display that shows past data seamlessly while recording continues.
- Input and output are modular: seven module types cover analog input, analog output, digital input, digital output, digital input/output, pulse input and PID control.
- Input signals per channel can be set to DC voltage, thermocouple, resistance temperature detector, contact or DC voltage DI, DC current or pulse, depending on the installed module.
- Large internal memory with data saved to an SD card, plus Ethernet for FTP file transfer, e-mail notification, web monitoring, Modbus/RTU and Modbus/TCP.
- Health Monitor and Profile functions for predictive detection, and a Future Pen function that draws a predicted waveform for reference alongside real-time data.
- Optional math function with report generation (hourly, daily, monthly), program control with up to 99 patterns, and PID control on up to 20 loops with PID modules (6 loops on the standard-memory type).
- Scan intervals from 1 ms to 5 s depending on module and measurement mode, including high-speed and dual-interval modes.
- Portable casing with a choice of AC power with a regional power cord, or 12 V DC supply, which suits vehicle-mounted or temporary installations.
GP10 technical specifications
| Item | Specification |
|---|---|
| Model | GP10, paperless recorder, portable type, small display |
| Type code | -1 standard (max. 100 measurement channels) |
| Display | 5.7-inch TFT color LCD, 640 x 480 dots, 4-wire resistive touch screen |
| Outside dimensions (modules fitted) | 144 x 168 x 248 mm (W x H x D) |
| Outside dimensions (no modules) | 144 x 168 x 197 mm |
| Weight | Approx. 1.9 kg, excluding modules |
| Module slots | Up to 3 modules in the main unit |
| Display groups | 30 groups, up to 10 channels each |
| Power supply codes | 1: 100 V AC or 240 V AC; 2: 12 V DC |
| Power consumption (100 V AC) | 16 VA backlight off, 20 VA normal operation, 48 VA maximum |
| Operating conditions | Ambient 0 to 50 degC, humidity 20 to 80 percent RH, no condensation |
| Communication | Ethernet (Modbus/TCP, FTP, e-mail, web); optional RS-232 (/C2) or RS-422/485 (/C3) |
The values above are taken from the manufacturer’s general specification for the GP10/GP20 portable paperless recorders. Treat the document as the controlling reference and confirm every figure against the latest revision before final design, because the manufacturer may change specifications without notice.
Typical applications in oil and gas, utilities, water and manufacturing
Paperless recorders suit temperature and process logging on heaters, boilers and furnaces, water and wastewater treatment plants, desalination units, power-station auxiliaries, pharmaceutical and food batch records, and test-bench or commissioning data capture in Oman and the GCC. They replace chart paper with SD card records that can be exported as files, which helps with audit trails and maintenance planning.
A buyer who already has the GP10 installed usually wants the same suffix code again, which keeps panel cutouts, terminal layouts, spare stocks and documentation unchanged. That is the main reason this exact part number is searched for rather than a generic description.
Selection and compatibility notes for the GP10
- Pick the power code to match the site: code 1 for mains supply, code 2 for 12 V DC; then pick the cord code for the destination country plug.
- The larger GP20 has a 12.1-inch display and bigger casing; use the GP10 when portability matters more than screen size.
- Modules are the same GX90 family used in the GX series, so spare analog input modules can be shared across GX and GP units of the same generation.
- Option /AS (advanced security function) and /BT (multi-batch function) are available as in the GX series.
Input modules and shunt resistors are listed in the I/O module general specification.
Installation and commissioning
Flush-mount the unit in a vertical panel within the panel thickness range, inclined backward no more than 30 degrees from horizontal, leaving room behind the panel for the module depth and wiring. Ground the case with a low-resistance connection, wire each input module to its terminal block, set input type, range and scale for each channel, then configure recording intervals, alarms, groups and the Ethernet or serial settings. Insert an SD card, check the date, time and daylight-saving setting, and verify a few channels against a calibrator before handing over.
Before energising a GP10 in a hazardous or critical service, confirm that the selected variant, enclosure rating and any approvals you require are covered by the order string and by your site rules.
Maintenance and spare parts
Maintenance consists of cleaning the screen, checking the SD card and internal memory status, backing up the configuration, verifying channel accuracy against a calibrator, and keeping firmware and security settings under review. Keep a spare SD card and record the main unit and module order strings, because modules must be matched to the host generation and terminal style when replaced.
Related products and ordering notes
The GP10 belongs to the GP10/GP20 portable paperless recorders group. Related family members, modules, software and accessories are listed in the same general specification, and we can quote them together with the GP10 when you need a complete panel or loop. Because many Yokogawa instruments are specified by long suffix strings, always quote the complete order code, the option codes, the quantity and the destination. If your installed unit is an older revision, send a nameplate photograph or the exact code printed on it so that compatibility can be checked before any quotation is issued.
Frequently asked questions about the GP10
- How is the GP10 different from the GX10? The GP10 has a portable casing with power supply and power-cord codes in the order string, while the GX10 is flush-mounted in a panel. Display size and channel capacity are similar.
- What power options exist for the GP10? Power supply code 1 covers 100 V AC or 240 V AC; code 2 is 12 V DC. The cord code selects the plug standard, or W for a screw terminal without a cord.
- How heavy is the GP10? The general specification gives approximately 1.9 kg excluding modules.
- Can the GP10 log temperature and 4-20 mA signals? Yes, with analog input modules it accepts thermocouple, RTD, DC voltage and DC current signals; the current input type module has a built-in shunt.
- What information do you need for a GP10 RFQ? Send the full order string with type, power supply code, power cord code and options, the quantity and the destination in Oman or the GCC.
Documents and quotation
The manufacturer’s datasheet for the GP10 is available on this page for download and lists the model and suffix codes, specifications and dimensions in full. To request a quotation, send the RFQ with the part number GP10, the quantity, any option codes and the delivery destination in Oman or the GCC. Our team will confirm availability, lead time and commercial terms for the GP10 by return.
Datasheets & Documents
- Datasheet Yokogawa GP10 Portable Paperless Recorder, 5.7-inch Touch Screen Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa GP10 Portable Paperless Recorder, 5.7-inch
Answers from our engineering team on installation, compatibility and integration.
01How is the GP10 different from the GX10?
The GP10 has a portable casing with power supply and power-cord codes in the order string, while the GX10 is flush-mounted in a panel. Display size and channel capacity are similar.
02What power options exist for the GP10?
Power supply code 1 covers 100 V AC or 240 V AC; code 2 is 12 V DC. The cord code selects the plug standard, or W for a screw terminal without a cord.
03How heavy is the GP10?
The general specification gives approximately 1.9 kg excluding modules.
04Can the GP10 log temperature and 4-20 mA signals?
Yes, with analog input modules it accepts thermocouple, RTD, DC voltage and DC current signals; the current input type module has a built-in shunt.
05What information do you need for a GP10 RFQ?
Send the full order string with type, power supply code, power cord code and options, the quantity and the destination in Oman or the GCC.


















Reviews