Brand: AMETEK
AMETEK 71072SE WDG-V Ferro Filter Assembly 30 Micron Probe
Description
AMETEK 71072SE overview
AMETEK 71072SE is the ferro filter assembly for the metal probe of the Thermox WDG-V analyzer, with a 30 micron rating. The AMETEK listing categorises it as a WDG-V 30 micron ceramic or metal probe filter. A probe filter protects the sample path from particulate in flue gas, and it is one of the parts that clogs first in dirty combustion processes, which makes it a frequent spare. The datasheet probe options include 316 SS, 310 SS and Hexoloy probes covering process temperatures up to 1648 degrees C.
The Thermox WDG-V is AMETEK Process Instruments’ close-coupled extractive analyzer for excess oxygen in flue gas. The datasheet describes a zirconium oxide sensor, measurement redundancy, continual diagnostic functions and SIL 2 capability for burner management systems, with flue gas temperatures up to 1648 degrees C (3000 degrees F) depending on the probe. It is completely field-serviceable, and the manual lists the spare parts by AMETEK part number.
Key features of 71072SE
- 30 micron probe filter assembly for WDG-V
- Intended for the metal probe version
- Protects the sample line from flue gas particulate
- Photo shows a dark rod with a threaded metal end
- Listed by AMETEK in the filters group of the WDG-V
- Used with 316 SS or 310 SS probe tubes
71072SE technical specifications
| Item | Detail |
|---|---|
| Part number | 71072SE |
| Description | Ferro filter assembly, metal probe, 30 micron |
| Category (AMETEK) | Filters, WDG-V 30 micron ceramic or metal probe |
| Probe options (datasheet) | 316 SS to 704 C, 310 SS to 1024 C, Hexoloy to 1648 C |
| Probe lengths (datasheet) | 910 to 2740 mm for metal probes, 600 to 1820 mm for Hexoloy |
| Max sample dew point (datasheet) | 200 C (392 F) |
| Principle (datasheet) | Zirconium oxide for excess oxygen |
| Output range | 0-1 percent to 0-100 percent O2 |
| Accuracy | Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent, whichever is greater |
| Response | 90 percent of a step change in under 11 seconds with flame arrestors |
| Aspirator air | About 3 SCFH at 3 to 6 psig, instrument air or nitrogen |
| Outputs | Three isolated linear current outputs, five alarms, Modbus RTU, HART option |
| Enclosure | Hinged IP65 (NEMA 4X) stainless steel |
| Power | 115 VAC or 230 VAC, plus or minus 10 percent, 740 VA maximum |
Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 71072SE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.
Typical applications in oil and gas, utilities, water and manufacturing
Process heaters, steam boilers and thermal oxidizers are the applications named in the datasheet, and the key markets are refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and across the GCC those applications correspond to refinery heaters, gas processing furnaces, utility boilers and thermal oxidizers on petrochemical and fertilizer sites, where excess oxygen is the primary indicator for burner efficiency and safe combustion.
Where 71072SE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.
Selection and compatibility notes for 71072SE
Confirm the analyzer version (O2 only, combustibles, or combustibles and methane), the supply voltage of the unit and, if possible, the AMETEK serial number before ordering. The WDG-V manual spare parts table is the reference that ties each number to a version.
Part number 71072SE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.
Installation and commissioning
Let the probe cool and isolate the analyzer from the process. Withdraw the probe and remove the used filter from the probe end following the maintenance information supplied with the analyzer, then fit 71072SE and refit the probe through the flange with new gaskets as needed. Check the aspirator air supply of about 3 SCFH at 3 to 6 psig stated in the datasheet and verify the oxygen reading after warm-up.
Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 71072SE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.
Maintenance and service life
Dirty filters show as reduced sample flow and slower response. Plan filter changes according to the particulate loading of the process, and keep a spare of 71072SE for processes with heavy dust.
Related products and ordering notes
Consider the exhaust tube 70619KE and sample probe (by serial number) listed in the manual, and the aspirator kit 7001-216-TE.
For a spare parts plan, list 71072SE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.
Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.
Frequently asked questions about 71072SE
- What is AMETEK 71072SE? It is a 30 micron ferro filter assembly for the metal probe of the Thermox WDG-V analyzer.
- Which probes does the WDG-V use? The datasheet lists 316 SS, 310 SS and Hexoloy probes with different temperature limits and lengths, so check the probe fitted to your analyzer.
- What air does the WDG-V aspirator need? The datasheet states about 3 SCFH at 3 to 6 psig of instrument air or nitrogen.
Documents and quotation
The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 71072SE, send the RFQ with the part number 71072SE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.
Datasheets & Documents
- Datasheet AMETEK WDG-V Flue Gas Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 71072SE WDG-V Ferro Filter Assembly 30
Answers from our engineering team on installation, compatibility and integration.
01What is AMETEK 71072SE?
It is a 30 micron ferro filter assembly for the metal probe of the Thermox WDG-V analyzer.
02Which probes does the WDG-V use?
The datasheet lists 316 SS, 310 SS and Hexoloy probes with different temperature limits and lengths, so check the probe fitted to your analyzer.
03What air does the WDG-V aspirator need?
The datasheet states about 3 SCFH at 3 to 6 psig of instrument air or nitrogen.
04How do I know the filter is blocked?
A blocked filter reduces sample flow, which the analyzer reports through its low sample flow diagnostic.
05How do I request a quotation for 71072SE?
Send the part number 71072SE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.


















Reviews
There are no reviews yet.