Hanna HI93414 Portable Turbidity and Chlorine Meter

Description

Hanna HI93414 portable turbidity and chlorine meter

The Hanna HI93414 is a portable microprocessor meter that combines ratio nephelometric turbidity measurement from 0.00 to 1000 NTU with free and total chlorine testing from 0.00 to 5.00 mg/L. One housing therefore covers the two parameters most often checked together on a treatment-plant walk. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

The turbidity side adapts US EPA Method 180.1 and Standard Method 2130 B; the chlorine side adapts US EPA Method 330.5 and Standard Method 4500-Cl G using DPD reagent. Many sites order the unit with its calibration standards and reagents so that it is usable on arrival.

HI93414 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments HI93414
Turbidity range 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU (automatic range selection)
Turbidity resolution 0.01 NTU to 9.99; 0.1 NTU from 10.0 to 99.9; 1 NTU from 100 to 1000
Turbidity accuracy ±2 % of reading plus 0.02 NTU
Turbidity repeatability / stray light ±1 % of reading or 0.02 NTU, whichever is greater; stray light below 0.02 NTU
Turbidity method Ratio nephelometric (90 degrees), ratio of scattered to transmitted light
Turbidity calibration Two, three or four points; standards below 0.1, 15, 100 and 750 NTU
Light source Tungsten filament lamp; lamp life above 100,000 readings
Chlorine ranges Free 0.00 to 5.00 mg/L; total 0.00 to 5.00 mg/L
Chlorine resolution / accuracy 0.01 mg/L to 3.50 mg/L, 0.10 above; ±0.02 mg/L at 1.00 mg/L
Chlorine detector Silicon photocell with 525 nm narrow-band interference filters
Memory / interface 200 log records; RS232 or USB 1.1
Display 60 × 90 mm LCD with backlight
Power Four 1.5 V AA alkaline batteries or AC adapter; auto shut-off after 15 minutes
Environment 0 to 50 °C; up to 95 % RH non-condensing
Size / weight 224 × 87 × 77 mm; 512 g
Warranty Two years

How the HI93414 works

For turbidity, a tungsten lamp lights the sample and detectors measure both light scattered at 90 degrees and light transmitted straight through; the meter uses the ratio of the two, which compensates for sample colour and lamp ageing and extends the linear range. Operators can choose normal, average or continuous measuring modes.

For chlorine, DPD reacts with free chlorine to give a pink tint, and a second reagent addition reveals total chlorine. The meter reads the tint at 525 nm and displays mg/L. A one-point chlorine calibration against 1 mg/L free and total standards is provided for periodic verification.

Where HI93414 fits: sensors, accessories and related models

Consumables are the turbidity standards (below 0.1, 15, 100 and 750 NTU), free and total chlorine reagent packets or liquids, cuvettes with caps, and silicone oil for cuvette wiping. The meter connects by RS232 or USB for data transfer, and can run from batteries or from an AC adapter on the bench.

The infrared ISO 7027 alternative for turbidity alone is the HI93703-11.

HI93414 family comparison

Model Turbidity method Other parameters Light source
HI93414 Ratio nephelometric, EPA 180.1 adaptation Free and total chlorine Tungsten lamp
HI93703-11 ISO 7027 infrared None Infrared LED

Choose the HI93414 when one instrument must give turbidity in NTU and chlorine residuals, as in filtration and disinfection monitoring; choose the HI93703-11 for ISO 7027 turbidity alone.

Selection and ordering checklist for HI93414

  • Confirm the need for both turbidity and chlorine in one instrument
  • Specify turbidity standards and calibration points (two, three or four)
  • Order DPD reagents for free and total chlorine and spare cuvettes
  • Decide on battery or AC adapter operation and RS232 or USB connection
  • Check whether silicone oil and cleaning supplies are needed

Installation, calibration and maintenance of HI93414

Calibrate turbidity with the standards below 0.1, 15, 100 and 750 NTU as appropriate to your range, using matched clean cuvettes. Calibrate chlorine against the 1 mg/L standards when verification is required. Always zero chlorine with the unreacted sample as directed in the manual.

Wipe cuvettes with lint-free cloth and a thin film of silicone oil, avoid fingerprints, and cap tightly to prevent evaporation. The lamp is rated for more than 100,000 readings, so lamp replacement is rare, but the optical well should be kept free from spills.

For turbidity near the bottom of the scale, bubbles and cuvette scratches dominate error. Let sample bubbles rise, invert gently, and keep a dedicated cuvette for low-level measurements. Run the continuous or averaging mode when the reading fluctuates, which smooths out particle noise.

For chlorine, analyse as soon as possible after sampling because chlorine decays; free and total tests use separate fresh samples and the reacted solution should be disposed of according to site rules.

Typical applications of HI93414 in Oman and the GCC

In Oman the HI93414 serves drinking-water works, hotel and resort water systems, bulk water tanker checks, desalination post-treatment and filtration monitoring, and municipal or industrial water distribution inspections where both clarity and disinfectant residual are logged. The 200-record memory and serial output help operators assemble compliance records.

A single bench-or-field meter simplifies training and calibration records for contractors who service many small water systems.

Information to send with an RFQ for HI93414

  • Quantity and calibration standards required
  • Chlorine reagent type and quantity (powder or liquid)
  • Spare cuvettes, silicone oil and AC adapter
  • Delivery location and lead time
  • Project or tender reference

Storage, handling and spares for the Hanna HI93414

Store the Hanna HI93414 in its case in a clean, dry place. Keep probes, electrodes and reagents as described in the user manual, as many of them need a storage solution or have a limited shelf life. In the GCC climate, keep reagents away from heat and direct sun and check expiry dates before use.

  • Calibrate the instrument with fresh standards at the interval your procedure requires.
  • Rinse probes and sample cells after each use and inspect them for scratches or deposits.
  • Keep spare consumables, such as reagents, standards, cuvettes and electrode solutions, in stock.
  • Record calibration results so that drift or probe ageing can be seen early.

When you order the Hanna HI93414, list the consumables and standards you need in the same RFQ, so the instrument can be used from the day it arrives.

Documents and quotation

The instruction manual for the HI93414 is attached on this page for specifications, calibration procedures and maintenance steps.

Send the part number HI93414, the quantity and your delivery location and we will reply with availability and a quotation.

Other Models in the Hanna Turbidity Range

Seven Star LLC supplies models from the Hanna Turbidity range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hanna HI93703-11 Portable ISO 7027 Turbidity MeterLiquid Analytical SystemsView details
Hanna HI93414 Portable Turbidity and Chlorine MeterLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Manual Hanna HI93414 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna HI93414 Portable Turbidity and Chlorine Meter

Answers from our engineering team on installation, compatibility and integration.

01What does the HI93414 measure?
Turbidity from 0.00 to 1000 NTU and free and total chlorine from 0.00 to 5.00 mg/L, in one portable meter.
02What turbidity method does it use?
Ratio nephelometric detection at 90 degrees, adapted from US EPA Method 180.1 and Standard Method 2130 B, with a tungsten lamp.
03How accurate is the turbidity reading?
Accuracy is 2 percent of reading plus 0.02 NTU, with repeatability of 1 percent of reading or 0.02 NTU and stray light below 0.02 NTU.
04How does it store and send data?
It logs 200 records and connects through RS232 or USB 1.1.
05How is it powered?
By four 1.5 V AA alkaline batteries or an AC adapter, with automatic shut-off after 15 minutes of non-use.