Fluke TiS60+ Thermal Camera, 320 x 240, 400 C

Description

TiS60+ 320 x 240 fixed-focus thermal camera with 45 mK sensitivity

The Fluke TiS60+ is a thermal camera for teams where operators of different experience share one unit. It has a 320 x 240 detector, a fixed-focus lens, a 3.5 in screen, a 400 °C range and the best sensitivity listed among the Fluke TiS cameras, 45 mK. The user simply points and shoots. Seven Star LLC supplies the TiS60+ in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The ordering list shows FLK-TiS60+ 30HZ and FLK-TiS60+ below 9HZ versions; the number is the frame rate.

TiS60+ technical specifications

Parameter Specification
Manufacturer / part number Fluke / TiS60+
Infrared resolution 320 x 240 (76,800 pixels)
IFOV 1.86 mRad, D:S 532:1
Field of view 34.1 ° H x 25.6 ° V
Focus Fixed; minimum focus distance 46 cm (18 in)
Thermal sensitivity (NETD) ≤ 0.045 °C at 30 °C (45 mK)
Temperature range -20 °C to 400 °C (not calibrated below -10 °C)
Accuracy ±2 °C or 2 % at 25 °C, whichever is greater
Display 3.5 in, 320 x 240 LCD
Visible camera / frame rate 5 MP / 30 Hz or below 9 Hz versions
Laser pointer / LED torch Yes / No
User spot markers 3, plus hot and cold spot markers
Memory Internal 4 GB and 4 GB micro SD
File formats Non-radiometric BMP or JPEG, or radiometric is2
Video Not available
IR-PhotoNotes 3 images
Battery Two lithium-ion smart packs, 4 hours continuous each, 2.5 hours charge
Operating / storage -10 °C to 50 °C / -20 °C to 50 °C without batteries
Enclosure / drop IP54 / 2 m
Size / weight 26.7 x 10.1 x 14.5 cm / 0.72 kg with battery

How the TiS60+ compares with its neighbours

The TiS60+ has the same 320 x 240 detector size as the Ti300+, but it trades laser focus and lens options for a simpler, lighter body and better sensitivity. It exceeds the TiS55+ in detector size and the TiS20+ MAX in temperature range. It is not intended for targets above 400 °C.

Model Detector Focus Max range NETD Weight
TiS60+ 320 x 240 Fixed 400 °C 45 mK 0.72 kg
Ti300+ 320 x 240 Laser auto 650 °C 75 mK 1.04 kg
TiS55+ 256 x 192 Manual 550 °C 40 mK 0.885 kg
TiS20+ MAX 120 x 90 Fixed 400 °C 60 mK 0.72 kg

Working with fixed focus and IR-Fusion

With fixed focus, images are sharp from 46 cm outward, so the camera suits quick scans of panels and machines. IR-Fusion records a visible image with each thermal image, and AutoBlend plus picture-in-picture modes let you view full infrared, full visible or mixed. This is valuable when contrast is low and the thermal picture alone does not show where the hot component is located.

Auto capture is also listed for the TiS60+, so the camera can log images at a chosen interval or temperature condition while it sits on a tripod facing a heating or cooling machine. Images and their visible companions are stored on the internal 4 GB memory or the micro SD card, and can be moved to a PC through the desktop software for reporting and trend comparison between inspection dates.

Three IR-PhotoNotes can be attached to each image, and three user-definable spot markers can be placed on the scene in addition to the hot and cold spot markers. Colour alarms for high temperature, low temperature and isotherms highlight pixels that fall inside or outside a chosen band, which is a quick way to flag components that exceed an acceptance limit during a walk-through.

Selection checklist for the TiS60+

  • Confirm 400 °C covers the hottest surface.
  • Pick 30 Hz or the below-9 Hz version.
  • Decide if fixed focus is acceptable; if not, choose the Ti300+.
  • Note that voice annotation needs a separately sold Bluetooth headset and that there is no text annotation or video.
  • Plan accessories: tripod mount, spare battery and charger.

Commissioning and care of the TiS60+

Supplied items include the camera, mains power supply with universal adapters, a two-bay smart battery charger, two batteries, USB cable, a 4 GB micro SD card, a hard carrying case, a soft transport bag and an adjustable hand strap. Check each item on receipt against the order.

Charge both batteries, fit the micro SD card and set emissivity from the material table. The camera has no transmission correction, so keep windows or protective screens out of the optical path unless you account for them separately. Clean the lens with a soft cloth. Calibration is recommended every two years in normal service, and the camera should be kept below 50 °C in operation.

Typical applications of the TiS60+ in Oman and the GCC

The TiS60+ is used for electrical inspections, mechanical bearings and couplings, HVAC and building thermal checks. In Oman and the wider Gulf, shared maintenance cameras on large sites benefit from the simple operation, while the 4 hour battery life covers a full inspection round. Direct sunlight on outdoor equipment can mislead readings, so scan shaded or cooled surfaces when possible.

Information to send with an RFQ for the TiS60+

  • Part number TiS60+ and frame-rate version
  • Quantity and accessories
  • Typical targets and temperatures
  • Delivery location and time frame
  • Calibration or warranty needs

Storage, handling and spares for the Fluke TiS60+

Keep the Fluke TiS60+ in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke TiS60+, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet for the TiS60+ is attached on this page.

Send us the part number TiS60+, the version and quantity and we will confirm availability and a quotation.

Other Models in the Fluke Tis Thermal Range

Seven Star LLC supplies models from the Fluke Tis Thermal range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke TiS20+ Thermal Imager, 120 x 90, IR-FusionThermal Imaging & IR ThermometersView details
Fluke TiS60+ Thermal Camera, 320 x 240, 400 CThermal Imaging & IR ThermometersYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke TiS60+ Thermal Camera, 320 x 240, 400 C

Answers from our engineering team on installation, compatibility and integration.

01What is the resolution of the Fluke TiS60+?
The TiS60+ has a 320 x 240 detector (76,800 pixels) with an IFOV of 1.86 mRad and a field of view of 34.1 by 25.6 degrees.
02Is the TiS60+ fixed focus?
Yes. It has fixed focus with a minimum focus distance of 46 cm, which makes it simple to use. It has no laser autofocus or interchangeable lens.
03What is the temperature range of the TiS60+?
The TiS60+ measures -20 °C to 400 °C. It is not calibrated below -10 °C, and its accuracy is the greater of 2 °C or 2 % at 25 °C.
04How good is the thermal sensitivity of the TiS60+?
The datasheet lists a thermal sensitivity (NETD) of 0.045 °C at a 30 °C target, or 45 mK, which is marked as the best possible value.
05How long does the TiS60+ run on a battery?
Each of the two lithium-ion smart batteries provides about 4 hours of continuous use, and a full charge takes about 2.5 hours.