Brand:

Fluke 115 True-RMS Field Technician Digital Multimeter

Description

115 compact field-technician multimeter explained

The Fluke 115 True-RMS Digital Multimeter (115) is a compact true-RMS digital multimeter for field service. It measures AC and DC voltage up to 600 V and current up to 10 A, with resistance, continuity, frequency and capacitance, in a body designed for one-handed use. Seven Star LLC supplies 115 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 110 series uses plain model numbers, so the table explains the identifiers and the figures that matter on a work order.

Element Value Meaning
115 Model Field-technician model of the 110 series
True-RMS Measurement Accurate on non-sinusoidal waveforms
CAT III 600 V Safety category IEC 61010-2-033
6000 counts Resolution Backlit digital display plus 33-segment bar graph

115 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 115
DC voltage 6.000 V to 600.0 V, accuracy 0.5% + 2
AC voltage (true-RMS) Up to 600 V, 1.0% + 3 (45 Hz to 500 Hz)
DC / AC current Up to 10 A (20 A overload for 30 s), 1.0% + 3 DC, 1.5% + 3 AC
Resistance 600 Ω to 40 MΩ, 0.9% + 1 up to 6 MΩ
Capacitance 1 nF to 9999 µF, 1.9% + 2 up to 1000 µF
Frequency Up to 50 kHz, 0.1% + 2
Display 6000 counts, 4 updates per second; bar graph 33 segments
Temperature (operating) -10 °C to +50 °C
Battery 9 V alkaline, about 400 hours typical without backlight
Size / weight 167 x 84 x 46 mm / 550 g
Warranty 3 years

Data are from the manufacturer product page and the detailed specification sheet for the 114/115/116/117 family.

How the Fluke 115 True-RMS Digital Multimeter works

The 115 measures with one-handed operation in mind: a rotary switch selects the function, the display shows a six-thousand-count value, and a bar graph supports trend watching. True-RMS conversion lets it read distorted waveforms from drives and electronic loads correctly within the stated frequency range.

Min/Max/Average with elapsed time records fluctuations over a period, which is useful for supply dips and intermittent contacts. The holster has probe holders, so leads can be parked without loose ends in a toolbag.

Key features

  • Min/Max/Average with elapsed time
  • Backlit 6000-count display
  • Frequency and capacitance functions
  • Holster with probe holders
  • Three-year warranty

Where 115 fits and related Fluke models

The 115 sits between the 114 (go/no-go with AutoVolt and LoZ) and the 117 (adds non-contact voltage detection and AutoVolt). The 116 is the HVAC-oriented variant with temperature and microamp functions. The 115 is the one for general field service when you do not need those extras.

For 1000 V environments, the 170 series (175, 177, 179) is the step up in rating.

Selection checklist for 115

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • Voltage rating: CAT III 600 V; for 1000 V work choose a 170 series model.
  • No temperature function; choose the 116 for HVAC temperature and microamps.
  • Current direct up to 10 A.
  • Leads and case: the pack includes a holster and PVC leads.

Safe use, care and maintenance of 115

  • Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 115 touches any live circuit.
  • Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
  • Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 115 True-RMS Digital Multimeter.
  • Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
  • Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.

Typical applications of 115 in Oman and the GCC

Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.

The 115 suits maintenance technicians on building services, small motors, lighting and control panels across industrial estates, utilities and facility management in Oman. Its compact size makes it easy to carry on an inspection round in hot, dusty plant areas.

115 compared with nearby models

Model Special function Category Typical user
113 VCHEK LoZ and capacitance CAT IV 600 V per specification table Utility, basic testing
114 AutoVolt and LoZ CAT III 600 V Go/no-go testing
115 Min/Max/Avg, frequency, capacitance CAT III 600 V Field technician
116 Temperature and microamps CAT III 600 V HVAC technician

The 113 uses a separate datasheet; the 114, 115 and 116 share a detailed specification sheet.

Information to send with an RFQ for 115

To prepare an accurate quotation, please send:

  • Exact model 115 and the quantity required.
  • Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
  • Required test lead type and any extra clips or probes.
  • Temperature probe, case or magnetic hanger requirements.
  • Whether calibration traceability paperwork is needed on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Storage, handling and spares for the Fluke 115

Store the Fluke 115 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.

  • Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
  • Use only leads and accessories rated for the same or a higher measurement category than the work you do.
  • Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
  • Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.

If your team uses several units of the Fluke 115, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.

Documents and quotation

A manufacturer datasheet for the Fluke 115 True-RMS Digital Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.

For a quotation, send the part number 115, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Other Models in the Fluke 110 Series Dmm Range

Seven Star LLC supplies models from the Fluke 110 Series Dmm range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Fluke 115 True-RMS Field Technician Digital MultimeterElectrical Testers & MultimetersYou are viewing this model
Fluke 116 HVAC True-RMS Multimeter with Temperature and uAElectrical Testers & MultimetersView details
Fluke 114 True-RMS Electrical Multimeter with AutoVoltElectrical Testers & MultimetersView details
Fluke 113 Utility Digital Multimeter with VCHEK LoZElectrical Testers & MultimetersView details
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 115 True-RMS Field Technician Digital

Answers from our engineering team on installation, compatibility and integration.

01What voltage can the Fluke 115 measure?
It measures AC and DC voltage up to 600 V and is rated CAT III 600 V. For up to 1000 V use one of the 170 series meters.
02Does the 115 measure temperature?
No. The 115 does not include a temperature input. The 116 adds temperature measurement and microamp ranges for HVAC work.
03What current ranges does the 115 offer?
It measures AC and DC current up to 10 A, with a 20 A overload permitted for a maximum of 30 seconds. Higher currents need a clamp meter.
04Is the display backlit?
Yes. It has a backlit 6000-count display with a 33-segment bar graph that updates 32 times per second.
05How long is the warranty?
The manufacturer lists a three-year warranty for the 115. Confirm warranty handling for units supplied in the GCC when quoting.