Brand:

Fluke 355 True-RMS 2000 A AC/DC Clamp Meter

Description

355 2000 A true-RMS clamp meter explained

The Fluke 355 True-RMS 2000 A Clamp Meter (355) is a heavy-duty true-RMS clamp meter for high-current work. A 58 mm jaw clamps large conductors and the instrument measures up to 1400 A AC and 2000 A DC, voltage to 1000 V, resistance and frequency. Seven Star LLC supplies 355 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The 355 shares a datasheet with the 353; the table below decodes the identifiers specific to the 355.

Element Value Meaning
355 Model 2000 A model of the 350 series
2000 A DC / 1400 A AC Current ranges Wide jaw for large cables and busbars
Inrush mode Peak capture Motor starting current measurement
CAT IV 600 V / CAT III 1000 V Safety rating Rugged enclosure

355 technical specifications

Parameter Specification
Manufacturer / part number Fluke / 355
AC current 40 A / 400 A / 1400 A, 1.5% rdg + 5 digits (10 Hz to 100 Hz)
DC current 40 A / 400 A / 2000 A, 1.5% rdg + 5 digits
AC voltage 4 V to 600 V, 1% rdg + 5 digits (10 Hz to 100 Hz)
DC voltage 4 V to 1000 V, 1% rdg + 5 digits
Resistance 400 Ω to 400 kΩ, 1.5% + 5 digits
Frequency 5.0 Hz to 1 kHz
Jaw size 58 mm (2.28 in)
Batteries Six AA, about 100 hours
Dimensions / weight 300 x 98 x 52 mm / 0.814 kg
IP rating 42 (indoor use only)
Drop test 1 m

Values are from the manufacturer product page and the 353/355 data sheet. The 355 is rated for indoor use.

How the Fluke 355 True-RMS 2000 A Clamp Meter works

The 355 uses a large Hall-effect jaw so that both AC and DC currents flow through its sensor without contact. The extra-wide jaw takes conductors typically used in high-current feeds, such as parallel cable runs and busbars.

In-rush mode measures the peak of motor starting current, and a low-pass filter smooths noisy loads. MIN, MAX and AVG are available to record changes, and the large display is backlit.

Key features

  • Jaw of 58 mm for large conductors
  • In-rush current mode
  • Low-pass filter
  • Voltage to 1000 V and resistance with continuity beeper
  • Frequency to 1 kHz

Where 355 fits and related Fluke models

The 355 is the instrument for feeders, transformer secondaries, battery banks and large motors. For smaller conductors and lower currents the 325 or 374 FC is easier to handle. When even larger or awkwardly routed conductors are involved, an iFlex-based clamp (375 FC) gives up to 2500 A AC.

The 353 is the 1400 A sibling that shares the datasheet.

Selection checklist for 355

Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.

  • Maximum current: 1400 A AC, 2000 A DC.
  • Jaw diameter 58 mm.
  • Indoor use only (IP 42).
  • Weight 0.8 kg; consider a case and strap.

Safe use, care and maintenance of 355

  • Close the jaw fully and check that the faces are clean. Dirt or rust on the jaw faces causes reading errors, and a jaw that does not close completely should be taken out of service.
  • Clamp only one conductor at a time. Two conductors of a single-phase pair or a three-phase set cancel each other and the 355 will show a value close to zero.
  • Verify the clamp on a known live circuit before and after any test that decides whether equipment is safe to touch.
  • Replace batteries when the low-battery indicator appears and remove them for long storage. Inspect the test leads for damage before each use of the voltage and resistance functions.
  • Keep the jaw and display free of dust. In dusty Gulf sites, use the supplied case and wipe the instrument after switchgear room work.
  • Respect the maximum conductor size and never clamp bare busbars unless the rating and your site procedure allow it. Treat the clamp as a measuring tool, not a switch or an isolator.
  • Allow the instrument to reach ambient temperature after moving it from an air-conditioned vehicle into a hot plant area, so that condensation does not form inside the housing and the display settles.
  • Schedule periodic calibration through your quality system, and keep the certificate with the instrument record so that readings used for reports remain traceable.

Typical applications of 355 in Oman and the GCC

Clamp meters are used for load checks on motors, feeders, chillers and pump drives. In Oman, maintenance teams at oil and gas plants, power and water utilities, desalination units and petrochemical sites use them for current surveys without opening circuits. A clamp reading showing a motor drawing more than its nameplate current points to a mechanical overload, a supply imbalance or a failing winding, while a reading near zero on a running pump suggests a lost phase or dry running. Because the circuit stays intact, these checks can be done on live equipment under a permit, which keeps downtime low during the hot summer months when cooling and pumping loads peak.

In Oman the 355 is used on DC battery systems in substations, on large pump and compressor feeders and on welding or electrolytic supplies. Its inrush mode helps commission motors and verify that starting current stays within protection settings.

355 compared with nearby models

Model Max AC Max DC Jaw
325 400 A 400 A 30 mm
374 FC 600 A (jaw) 600 A 34 mm
355 1400 A 2000 A 58 mm

The 374 FC and 375 FC extend range via an optional iFlex probe.

Information to send with an RFQ for 355

To prepare an accurate quotation, please send:

  • Exact model 355 and the quantity required.
  • Maximum conductor size and expected current, so the jaw or flexible probe option can be confirmed.
  • Whether wireless or smartphone use is needed on site.
  • Any extra accessories such as a hanging strap, leads or a case.
  • Calibration traceability paperwork if required on delivery.
  • Delivery point in Oman or elsewhere in the GCC and the required date.

Documents and quotation

A manufacturer datasheet for the Fluke 355 True-RMS 2000 A Clamp Meter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.

For a quotation, send the part number 355, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 355 True-RMS 2000 A AC/DC Clamp Meter

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum current of the Fluke 355?
1400 A AC and 2000 A DC, each at 1.5% reading plus 5 digits on the high ranges.
02How large is the jaw opening?
The jaw size is 58 mm (2.28 in), wide enough for the large conductors typical of high-current feeders.
03Does it have an inrush function?
Yes, an in-rush mode captures motor starting peak current.
04Is the 355 rated for outdoor use?
The manufacturer states IP 42 for indoor use only.
05What batteries does it use?
Six AA batteries with about 100 hours typical life with the backlight off.