Brand: Schneider Electric
Schneider Electric METSEPM1200 PowerLogic PM1200 Power Meter
Description
METSEPM1200 panel power meter with energy and demand and communication
The METSEPM1200 is a Schneider Electric product listed in the datasheet as: PM1200 power meter with energy and demand – with communication. The METSEPM1200 is a PowerLogic PM1200 panel-mounted power meter that measures electrical quantities, energy and demand, with a communication port. The datasheet marks it as discontinued. Seven Star LLC supplies the METSEPM1200 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: METSE is the PowerLogic prefix, PM1200 the model.
Technical specifications of the METSEPM1200
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / METSEPM1200 |
| Description | PM1200 power meter with energy and demand – with communication |
| Range of Product | PowerLogic PM1000 |
| Device short name | PM1200 |
| Product or Component Type | Power meter |
| Power quality analysis | Up to the 9th harmonic |
| Type of measurement | Current; Voltage; Frequency; Active and reactive power; Active and reactive energy; Power factor |
| supply voltage | 44 to 277 V AC 50/60 Hz; 44 to 277 V DC |
| Network Frequency | 50/60 Hz |
| Maximum power consumption in | 3 VA 240 V AC |
| Display Type | LED |
| Display Resolution | 3 lines with 4 digits |
| Sampling rate | 20 samples/cycle |
| Measurement current | 50 to 6000 mA |
| input type | Current 0 to 5 A (impedance <= 0.1 Ohm); Current 0 to 1 A (impedance <= 0.1 Ohm) |
| Measurement voltage | 80 to 480 V AC 50/60 Hz phase to phase; 0 to 999000 V AC 50/60 Hz with external VT |
| Measurement accuracy | Power 1 %; Current 1 %; Voltage 1 %; Energy 1 %; Frequency 0.1 %; Power factor 1 %; Apparent power 1 % |
| Accuracy class | Class 2 reactive energy IEC 62053-23; Class 1 active energy IEC 62053-21 |
| Communication port protocol | Modbus 19.2 kbauds |
| Communication port support | RS485 |
| Electromagnetic compatibility | Immunity to impulse waves IEC 61000-4-12; Electrostatic discharge immunity test IEC 61000-4-2 |
| Mounting Mode | Flush-mounted |
| Mounting support | Panel |
| Type of Installation | Indoor installation |
| Overvoltage category | III |
| IP degree of protection | IP51 front face: conforming to IEC 60529; IP40 back: conforming to IEC 60529 |
| Relative humidity | 5 to 95 % |
| Ambient air temperature (operation or storage, as listed) | -25 to 70 °C |
| Operating altitude | 0 to 2000 m |
| Standards | IEC 62053-21; IEC 62052-11 |
| Width | 96 mm |
| Depth | Embedded : 80 mm |
| Height | 96 mm |
| Net Weight | 0.4 kg |
Measurement data of the METSEPM1200
Network frequency: 50/60 Hz. Communication protocols: Modbus 19.2 kbauds. Display: LED. Resolution: 3 lines with 4 digits.
The meter measures voltage, current, power and energy. See the datasheet for accuracy and display.
Replacement and network use of the METSEPM1200
Confirm the successor, such as PM2100 or PM5000 series. Communicate via the port to a SCADA or energy system.
The datasheet downloaded for this page carries lifecycle notices: Discontinued on: Jan 23, 2021. For a plant that already runs this reference that makes the METSEPM1200 a spare-and-replacement item, and it is worth fixing the stock level and the long-term successor plan at the same time. We can discuss compatible alternatives once we know the installation.
Selection checklist for the METSEPM1200
- Measurements.
- Communication.
- Mounting.
- Lifecycle.
- CT ratio.
- Supply.
Wiring and set-up of the METSEPM1200
Connect voltage and CT inputs, set ratios and test readings.
Record parameters.
Typical applications of the METSEPM1200 in Oman and the GCC
In Oman and the GCC panel meters monitor feeders and motors.
Dimensions, environment and approvals of the METSEPM1200
For the METSEPM1200, plan the mounting space from the datasheet: 96 mm (W) x 96 mm (H) x Embedded : 80 mm (D). The METSEPM1200 weighs 0.4 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -25 to 70 °C. Relative humidity: 5 to 95 %. Ingress protection: IP51 front face: conforming to IEC 60529; IP40 back: conforming to IEC 60529. Operating altitude: 0 to 2000 m. Standards listed: IEC 62053-21; IEC 62052-11.
Panel power meters are valued for the data they give over years, so the set-up of the METSEPM1200 is important. Enter the CT and VT ratios correctly at commissioning, because an error here multiplies through every reading; check by comparing with a clamp meter. Where energy is used for cost allocation, record the meter serial number and the date of installation so that readings can be traced. The communication port allows the meter to send data to a SCADA or energy-management system; use the register map from the manual to choose the values to collect, such as current, power factor, kWh and demand. As the datasheet shows the reference as discontinued, plan for a successor from the PowerLogic range; the front-panel cut-out and CT connections need to be compared before replacement. Keep a spare if the meter is used for billing. If the meter feeds a building or energy management system, agree on the polling interval and the registers with the system integrator before commissioning; polling too fast can load a serial link, and polling too slowly loses short demand peaks. Keep a table of ratios, wiring mode and communication settings on the cabinet door or in the panel documentation, so a replacement meter can be configured in minutes. Where several feeders are metered, use a consistent naming scheme for the meter addresses.
Information to send with an RFQ for the METSEPM1200
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Site conditions in Oman for the METSEPM1200
Electrical rooms and outdoor panels in the Gulf often operate well above the 25 °C reference temperature used in many catalogues. Before you finalise the METSEPM1200, compare the expected panel temperature with the operating range and any output derating stated in the manufacturer documentation, and leave the recommended clearance above and below the device for convection. Supply quality also varies between sites, so confirm the input voltage range, frequency and any requirements for protection on the supply side.
Where the device feeds or monitors critical loads, plan how faults will be signalled to the control system and how a replacement can be installed quickly. Keeping one spare METSEPM1200 per site and recording its settings helps maintenance teams in Oman restore service with minimum downtime.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric METSEPM1200 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric METSEPM1200 PowerLogic PM1200
Answers from our engineering team on installation, compatibility and integration.
01What is the net weight of the METSEPM1200?
The datasheet gives 0.4 kg.
02What ingress protection does the METSEPM1200 list?
Stated as IP51 front face: conforming to IEC 60529; IP40 back: conforming to IEC 60529.
03Which standards does the METSEPM1200 list?
Listed: IEC 62053-21; IEC 62052-11.
04Which product range does the METSEPM1200 belong to?
The datasheet lists the range as PowerLogic PM1000.
05What is the device short name of the METSEPM1200?
The datasheet gives PM1200.