- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric A9MEM3250 Acti9 iEM3250 Energy Meter CT
Description
A9MEM3250 Acti9 iEM3250 DIN-rail energy meter for CT connection
The A9MEM3250 is a Schneider Electric product listed in the datasheet as: iEM3250 energy meter – CT – Modbus. The A9MEM3250 (iEM3250) is a three-phase DIN-rail energy meter for use with current transformers. It measures active energy with class 0.5S accuracy and communicates over Modbus RS485, making it useful for sub-billing and cost allocation. Seven Star LLC supplies the A9MEM3250 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: A9MEM is the Acti9 energy-meter family code and 3250 the iEM3250 model with CT inputs and Modbus. The datasheet lists 3P, 3P+N and 1P+N network types.
Technical specifications of the A9MEM3250
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9MEM3250 |
| Description | iEM3250 energy meter – CT – Modbus |
| Range | Acti9 |
| range of product | Acti9 iEM3000 |
| Product or Component Type | Energy meter |
| Device short name | iEM3250 |
| Market segment | Buildings small building cost management: billing: main incomer; Buildings small building cost management: billing: sub feeder |
| Poles description | 3P; 3P + N; 1P + N |
| Type of measurement | Active energy; Current; Voltage; Active power |
| Device Application | Sub billing; Partial meter |
| Accuracy class | Class 0.5S active energy IEC 62053-22; Class 0.5S active energy IEC 61557-12 |
| input type | Current transformer 1 A or 5 A |
| Line Rated Current | 5A; 1A |
| Rated voltage | 100 to 277 V; 173 to 480 V |
| Network Frequency | 50 Hz; 60 Hz |
| Technology Type | Electronic |
| Display Type | LCD display |
| Sampling rate | 32 samples/cycle |
| Measurement current | 1 to 32767000 mA |
| Maximum value measured | 99999999 MWh |
| Communication port protocol | Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none 4000 V |
| Communication port support | Screw terminal block RS485 |
| Local signalling | Green indicator light power ON; Yellow flashing LED accuracy checking |
| Number of inputs | 0 |
| Number of Outputs | 0 |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| Connections – terminals | Current circuit screw terminals 6 mm²; Voltage circuit screw terminals 2.5 mm² |
| Overvoltage category | III |
| Standards | BS EN 61557-12:2021; IEC 61557-12:2021; EN 61557-12:2021; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11:2020; IEC 62052-11:2020 |
| Product certifications | CE IEC 61010-1 safety; CE EN 61557-12 power monitor; CE EN/IEC 61326-1 EMC; UKCA BS EN 61010-1 safety; UKCA BS EN 61557-12 power monitor |
| Compatibility code | IEM3250 |
| IP degree of protection | IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529 |
| Pollution degree | 2 |
| Relative humidity | 5 to 95 % 50 °C |
| Ambient air temperature (operation or storage, as listed) | -25 to 70 °C – IEC |
| Operating altitude | < 3000 m |
| Color | White |
| 9 mm pitches | 10 |
| Width | 90 mm |
| Height | 95 mm |
| Depth | 69 mm |
Measurement, accuracy and display of the A9MEM3250
Measured quantities: Active energy; Current; Voltage; Active power. Accuracy class: Class 0.5S active energy IEC 62053-22; Class 0.5S active energy IEC 61557-12. CT secondary: 5A; 1A. Voltage: 100 to 277 V; 173 to 480 V. Display: LCD display. Sampling: 32 samples/cycle. Protocol: Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none 4000 V. Counter range: 99999999 MWh.
The meter counts energy locally and keeps its counters in non-volatile memory, so a power outage does not lose billing data. It reads current from external transformers of 1 A or 5 A secondary, which allows monitoring of large feeders in a small enclosure.
The A9MEM3250 in a DIN-rail metering layout
As a DIN-rail device it sits in the distribution board beside Acti9 circuit breakers. Other iEM3000 models include direct-connected versions and pulse-output versions; this CT version covers feeders above the direct limit.
Communication is Modbus RTU on RS485; a gateway can bring the data onto Ethernet for a supervisory system.
Selection checklist for the A9MEM3250
- Feeder current and the matching CT ratio.
- Accuracy class 0.5S sufficient.
- Modbus RS485 availability.
- Network type: 3P, 3P+N or 1P+N.
- Panel space: DIN rail module width.
- Whether a certified revenue meter is required by the utility.
Installing and commissioning the A9MEM3250
Clip onto the rail, wire the CT secondaries (observing polarity), voltage inputs with protective fuses, and the RS485 pair. Set the CT ratio and network type from the front buttons.
Check that the power direction is positive for a load; swap CT leads if negative. Record initial counters at handover.
Typical applications of the A9MEM3250 in Oman and the GCC
Tenant sub-billing, cost allocation in industrial parks, building energy management and large HVAC plant monitoring in the region.
Dimensions, environment and approvals of the A9MEM3250
For the A9MEM3250, plan the mounting space from the datasheet: 90 mm (W) x 95 mm (H) x 69 mm (D). Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -25 to 70 °C – IEC. Relative humidity: 5 to 95 % 50 °C. Ingress protection: IP40 front panel: conforming to IEC 60529; IP20 body: conforming to IEC 60529. Operating altitude: < 3000 m. Standards listed: BS EN 61557-12:2021; IEC 61557-12:2021; EN 61557-12:2021; BS EN 61326-1; IEC 61326-1; EN 61326-1; BS EN 62052-11:2020; IEC 62052-11:2020. Certifications listed for this reference: CE IEC 61010-1 safety; CE EN 61557-12 power monitor; CE EN/IEC 61326-1 EMC; UKCA BS EN 61010-1 safety; UKCA BS EN 61557-12 power monitor.
Information to send with an RFQ for the A9MEM3250
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Site conditions in Oman for the A9MEM3250
Electrical rooms and outdoor panels in the Gulf often operate well above the 25 °C reference temperature used in many catalogues. Before you finalise the A9MEM3250, compare the expected panel temperature with the operating range and any output derating stated in the manufacturer documentation, and leave the recommended clearance above and below the device for convection. Supply quality also varies between sites, so confirm the input voltage range, frequency and any requirements for protection on the supply side.
Where the device feeds or monitors critical loads, plan how faults will be signalled to the control system and how a replacement can be installed quickly. Keeping one spare A9MEM3250 per site and recording its settings helps maintenance teams in Oman restore service with minimum downtime.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric A9MEM3250 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9MEM3250 Acti9 iEM3250 Energy
Answers from our engineering team on installation, compatibility and integration.
01What accuracy class has the A9MEM3250?
The datasheet states Class 0.5S active energy IEC 62053-22; Class 0.5S active energy IEC 61557-12.
02What CT secondary does the A9MEM3250 accept?
Listed: 5A; 1A.
03What communication does it have?
Datasheet: Modbus RTU 9.6, 19.2 and 38.4 kbauds even/odd or none 4000 V.
04What voltage range does it measure?
Range: 100 to 277 V; 173 to 480 V.
05What display does it have?
Listed: LCD display.


















Reviews