Brand: Endress+Hauser (E & H)
Micropilot FMR52 Radar Level Transmitter
Description
Overview
The Micropilot FMR52 is Endress+Hauser’s radar level transmitter designed for applications in aggressive liquids, offering extraordinary advantages with its completely PTFE-filled and flush-mounted horn antenna. The FMR52 also serves as the sensor of choice for hygiene-sensitive applications in the food and life sciences industry, carrying ASME BPE, USP Class VI, 3-A, and EHEDG approvals.
Seven Star LLC supplies the Micropilot FMR52 on request to chemical processing, food and beverage, and pharmaceutical facilities across the Sultanate of Oman, Muscat, and the wider GCC. Micropilot is used for continuous, non-contact level measurement of liquids, pastes, and slurries, with measurement unaffected by changing media, temperature changes, gas blankets, or vapors that would confuse a contact-based level instrument.
Measurement Principle
The Micropilot FMR52 operates as a downward-looking time-of-flight (ToF) measuring system: radar impulses are emitted by the antenna, reflected off the product surface, and received again by the radar system, with the distance from the reference point (process connection) to the product surface computed from the time delay. Operating in the K-band at approximately 26GHz, the FMR52 achieves ±2mm accuracy across a maximum measuring range of 40m (131 ft), extending to 60m (197 ft) in extended configurations.
The flush-mounted, PTFE-encapsulated horn antenna design eliminates crevices or protrusions into the process, making it ideally suited to aggressive, corrosive, or hygienic media where a conventional metallic antenna would be unsuitable. The measurement remains reliable even in the presence of gas blankets, vapor layers, and changing dielectric properties, thanks to Multi-Echo Tracking evaluation.
Engineering Design of the Micropilot FMR52
The Micropilot FMR52 operates across a process temperature range of -196°C to +200°C (-321°F to +392°F) and a pressure range of -1 to 25 bar (-14.5 to 362 psi), with hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy. HistoROM data management provides fast and easy commissioning, maintenance, and diagnostics, while Heartbeat Technology supports cost-effective and safe plant operation across the entire instrument life cycle.
The transmitter is available with a dual-compartment housing in either plastic PBT or 316L stainless steel construction, with 2-wire 4-20mA HART output as standard and optional Bluetooth remote access via the SmartBlue app. A 4-line SD02 display with push buttons and data backup function supports local operation, and seamless integration into control or asset management systems is achieved through an intuitive, menu-guided operation concept.
Key Features
The Micropilot FMR52 combines hygienic, flush-mounted antenna design with robust radar measurement performance. Core capabilities include:
- Completely PTFE-encapsulated, flush-mounted horn antenna for aggressive liquids.
- ASME BPE, USP Class VI, 3-A, and EHEDG approvals for food, life sciences, and pharmaceutical applications.
- ±2mm accuracy with 26GHz K-band radar operation.
- Measuring range up to 40m (131 ft), extending to 60m (197 ft) in enhanced configurations.
- SIL3-capable hardware and software (IEC 61508, homogeneous redundancy).
- HistoROM data management and Heartbeat Technology for lifecycle diagnostics.
- Optional Bluetooth remote access via SmartBlue app for commissioning and maintenance.
- Process temperature -196°C to +200°C; pressure range -1 to 25 bar.
Industrial Applications
The Micropilot FMR52 is well suited to chemical processing, food and beverage production, and pharmaceutical manufacturing across Oman requiring hygienic, non-contact level measurement of aggressive or sanitary liquids, pastes, and slurries. Its flush-mounted antenna design eliminates dead zones and crevices that could harbor contamination, making it a preferred choice for hygiene-sensitive process vessels.
Seven Star LLC quotes the Micropilot FMR52 to chemical plants, food processing facilities, and pharmaceutical manufacturers in Oman and the broader GCC region with the Micropilot FMR52’s reliable, hygienic level measurement capability.
Technical Specifications
Full technical parameters for the Micropilot FMR52 radar level transmitter:
| Parameter | Specification |
|---|---|
| Model | Micropilot FMR52 |
| Measurement Principle | Free-Space Radar (Time-of-Flight) |
| Accuracy | ±2mm (0.08 in) |
| Frequency | K-Band (~26GHz) |
| Max Measuring Range | 40m (131 ft); 60m (197 ft) Enhanced |
| Process Temperature | -196°C to +200°C (-321°F to +392°F) |
| Process Pressure | -1 to 25 bar (-14.5 to 362 psi); DN150 / 6-8 in flanges above +100 °C: 0 to 25 bar |
| Antenna | PTFE-Encapsulated, Flush-Mounted Horn |
| Communication | 4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus; Optional Bluetooth (SmartBlue App) |
| Safety Certification | SIL3-Capable (IEC 61508, Homogeneous Redundancy) |
| Hygienic Approvals | ASME BPE, USP Class VI, 3-A, EHEDG |
| Antenna sizes / beam angle | Flush-mount PTFE-filled horn 50 mm (2 in): 18 degrees; 80 mm (3 in): 10 degrees |
| Beam diameter examples | 50 mm antenna: 0.95 m at 3 m, 3.80 m at 12 m; 80 mm antenna: 0.53 m at 3 m, 2.1 m at 12 m |
| Range, 80 mm antenna, storage vessel | Standard: A 8 m, B 15 m, C 30 m, D 40 m; with Advanced dynamics: A 10 m, B 20 m, C 40 m, D 60 m |
| Range in stilling well / bypass | Stilling well 20 m for media groups A to D; bypass 20 m for groups C and D |
| Advanced dynamics | Application package (order feature 540, option EM); raises max range from 40 m to 60 m |
| Supply voltage (terminal) | HART: 10.4 to 35 V (Ex ia 10.4 to 30 V; Ex d(ia) 13 to 35 V); HART + switch output 13 to 35 V; +3 V with Bluetooth module |
| Process connections | ASME 2-8 in 150/300 lbs; EN DN50-DN150 PN10/16, DN80/DN100 PN25/40; JIS 10K 50A-150A; DIN 11851 DN50/DN80; Tri-Clamp 2, 3, 4 in |
| Housings | GT18 316L; GT19 plastic PBT; GT20 aluminium coated; IP66/IP68, NEMA 4X/6P |
| Ambient temperature | -50 to +80 °C |
| Nozzle / wall rules | Max nozzle height 500 mm for both antenna sizes; not closer than 15 cm to tank wall |
| Other approvals | WHG; NACE MR0175 / MR0103; marine GL, ABS, LR, BV, DNV |
FMR52 Antenna Sizes, Beam Angle and Measuring Range
The Micropilot FMR52 is supplied with a flush-mounted, PTFE-filled horn antenna in two sizes. The 50 mm (2 inch) antenna has a 3 dB beam angle of 18 degrees and the 80 mm (3 inch) antenna 10 degrees. In practical terms the beam diameter at 12 m distance is about 3.8 m for the small antenna and 2.1 m for the large one, so the 80 mm version is the better choice wherever internals or the tank wall lie close to the measuring path.
The standard device has a maximum measuring range of 40 m. The 60 m figure is only reached with the Advanced dynamics application package (order feature 540, option EM). For the 80 mm antenna in a storage vessel with a calm surface, Endress+Hauser gives 8 m, 15 m, 30 m and 40 m for medium groups A, B, C and D as standard, and 10 m, 20 m, 40 m and 60 m with Advanced dynamics. Moving surfaces and agitators reduce these values considerably.
Where the dielectric constant is low or the surface is turbulent, a stilling well or bypass is the remedy recommended by the manufacturer. In a stilling well the FMR52 measures up to 20 m in all medium groups from A to D; in a bypass 20 m applies to groups C and D. The device works in the K-band at about 26 GHz, which allows up to eight Micropilot transmitters in one tank.
FMR52 Process Connections, Pressure Limits and Mounting
All FMR52 process connections are PTFE clad, so only PTFE is wetted. For flanges from DN50 to DN100 (2 to 4 inch), DIN 11851 couplings and Tri-Clamp fittings, the permitted range is -196 to +200 °C at -1 to 25 bar. The large flanges (DN150, 6 and 8 inch) keep the 25 bar limit, but vacuum is only allowed up to +100 °C; between 100 and 200 °C the lower pressure limit is 0 bar gauge. The actual rating is always limited by the flange class selected.
Because the antenna is flush, a nozzle up to 500 mm high is acceptable for both antenna sizes. The PTFE flange cladding normally serves as the gasket between nozzle and device flange. The device should sit at least 15 cm from the tank wall. For loop design, the HART version needs 10.4 to 35 V at the terminals, 13 V minimum with switch output or flameproof electronics, and 3 V more when the Bluetooth module is fitted.
Why Choose Seven Star LLC for Hygienic Radar Level Measurement
A flush-mounted, PTFE-encapsulated antenna is specified precisely because a conventional metallic antenna would either corrode in an aggressive chemical service or fail a hygienic-design audit in a food or pharmaceutical vessel – getting the antenna material, process connection, and hygienic certificate combination wrong is a common and expensive ordering mistake. Seven Star LLC’s engineers confirm the exact process connection standard (tri-clamp, DIN, ASME BPE) and the required hygienic certificates against the customer’s actual vessel and industry auditor requirements before the Micropilot FMR52 is ordered. We also help plan spare transmitter electronics around the instrument’s SIL3-capable architecture for safety-relevant installations, and note that the optional Bluetooth module allows commissioning with the SmartBlue app without opening the process connection.
Request a Quote for Micropilot FMR52 Radar Level Transmitter
To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Micropilot FMR52 Radar Level Transmitter, please contact the instrumentation division at Seven Star LLC today. Our team can review your requirement and confirm lead time at quotation for your hygienic and aggressive-liquid level measurement projects.
Related Products
- ABB-STW
- ABB MT5200 Guided Wave Radar Level Transmitter
- JUMO NESOS R20 LT Float Level Transmitter
- ABB-Magnetic level gauge KM26
- Endress+Hauser Micropilot FMR20 Compact Radar Level Transmitter
- VEGA VEGAPULS 64 Radar Level Sensor
See also: Endress+Hauser Liquiphant FTL51 Vibronic Point Level Switch.
Datasheets & Documents
- Instruction Manual Endress+Hauser (E & H) Micropilot FMR52 Radar Level Transmitter Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Micropilot FMR52 Radar Level Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What makes the FMR52 suitable for hygienic applications?
The FMR52 features a completely PTFE-encapsulated, flush-mounted horn antenna with ASME BPE, USP Class VI, 3-A, and EHEDG approvals, eliminating crevices that could harbor contamination.
02What accuracy and range does the FMR52 achieve?
The FMR52 achieves ±2mm accuracy using 26GHz K-band radar, with a maximum measuring range of 40m (131 ft), extending to 60m (197 ft) in enhanced configurations.
03Is the FMR52 suitable for safety instrumented systems?
Yes. Hardware and software are developed according to IEC 61508 up to SIL3 in homogeneous redundancy.
04Can the FMR52 be configured remotely?
Yes. Optional Bluetooth connectivity via the SmartBlue app allows remote commissioning, maintenance, and diagnostics.
05Is Seven Star LLC a trusted supplier for Endress+Hauser products?
Seven Star LLC supplies Endress+Hauser instrumentation to customers in Oman and the GCC on request, with lead time confirmed at quotation.