Brand: SICK
SICK V2D631R-MKMEB1 Lector63x Identification Sensor
Description
V2D631R-MKMEB1 is a SICK Lector63x identification device (part no. 1080076) that reads codes or RFID tags so that products and containers can be tracked automatically. The catalogue summary lists: variant: Complete device; optical focus: Adjustable focus (manual); sensor resolution: 1,280 px x 1,024 px (1.3 MP); illumination color: White; focal length: 16 mm.
V2D631R-MKMEB1: function, principle and typical use
Identification readers feed the control system with the identity of each item: a barcode or 2D code on a label, or an RFID transponder. Most readers send decoded data over Ethernet or serial interfaces and can trigger from a photoelectric sensor or run in continuous mode.
Telegram format and filtering are configured in the SICK software. RFID reads many tags in a field at once and does not need line of sight, which suits tote and pallet tracking.
Technical specifications
| Parameter | Specification |
|---|---|
| Type code | V2D631R-MKMEB1 |
| Part number | 1080076 |
| Product family | Lector63x |
| Variant | Complete device |
| Optical focus | Adjustable focus (manual) |
| Sensor | CMOS monochrome |
| Sensor resolution | 1,280 px x 1,024 px (1.3 MP) |
| Illumination | Integrated |
| Illumination color | White, LED, Visible, |
| Feedback spot | LED, Visible, green, 525 nm, ± 15 nm; LED, Visible, Red, 630 nm, ± 20 nm |
| Alignment aid | Laser, Red, 630 nm … 680 nm |
| Laser class | 1, Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed.3., as described in “Laser Notice No. 56” dated May 8, 2019 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021) |
| Lens | C-mount (compact) |
| Optical format | 1/1.8″ |
| Focal length | 16 mm |
| Aperture | 8 |
| Scanning frequency | ≤ 50 Hz, With resolution of 1.3 megapixels |
| Code resolution | ≥ 0.1 mm |
| Working range | 50 mm … 2,200 mm |
| Connection type | 1 x M12, 17-pin plug (serial, CAN, I/Os, power supply); 1 x M12, 8-pin socket (Ethernet, 1 GBit/s); 1 x M8, 4-pin socket (USB); 1 x M12, 4-pin socket (external illumination control) |
| Supply voltage | 12 V DC … 24 V DC, ± 20 % |
| Power consumption | Typ. 10 W, ± 20 % |
| Output current | ≤ 100 mA |
| Housing material | Aluminum die cast |
| Window material | Plastic |
| Enclosure rating | IP67 (EN 60529 (1991-10), EN 60529/A2 (2002-02)) |
| Electrical safety | EN 60950-1 (2011-01) |
| Weight | 590 g |
| Dimensions (L x W x H) | 108 mm x 63.1 mm x 96.4 mm |
| Readable code structures | 1D codes, Stacked, 2D codes |
| Declarations and certificates in the data sheet | EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; China RoHS; cULus certificate; Profinet certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854) |
Type code V2D631R-MKMEB1 and what to check before ordering
For the control cabinet and the cable run, the relevant figures are supply is 12 V DC … 24 V DC, ± 20 %; interface is optional over external fieldbus module CDF600-2; power draw is typ. 10 W, ± 20 %; frequency is ≤ 50 Hz, With resolution of 1.3 megapixels; resolution is 1,280 px x 1,024 px (1.3 MP); current is ≤ 100 mA.
For the mounting location, note vibration of EN 60068-2-6:2008-02; weight of 590 g; operating temperature of 0 °C … +50 °C; enclosure rating of IP67 (EN 60529 (1991-10), EN 60529/A2 (2002-02)); dimensions of 108 mm x 63.1 mm x 96.4 mm; housing of aluminum die cast; storage temperature of –20 °C … +70 °C; shock of EN 60068-2-27:2009-05.
Typical uses are conveyor sorting, pallet and tote tracking, work-in-process traceability and warehouse gates.
Keep the reader window and the code area clean; label quality is often the weakest link.
Documents and quotation
The official SICK data sheet for V2D631R-MKMEB1 (part no. 1080076) is attached as a PDF. Send the type code, quantity and delivery location through the RFQ form and Seven Star LLC, an independent supplier in Muscat, will respond with a quotation. Similar products sit under Machine Vision. Confirm the full code against the device it replaces; if this page and the data sheet ever disagree, follow the data sheet.
Datasheets & Documents
- Data Sheet SICK V2D631R-MKMEB1 official data sheet (part no. 1080076) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
Related products
Frequently Asked Questions
It is a SICK identification sensor (Lector63x), part no. 1080076. The catalogue summary reads: Variant: Complete device; Optical focus: Adjustable focus (manual); Sensor resolution: 1,280 px x 1,024 px (1.3 MP); Illumination color: White.
Supply voltage is 12 V DC ... 24 V DC, ± 20 %. Check the output and interface rows in the table for the signal levels.
Enclosure rating: IP67 (EN 60529 (1991-10), EN 60529/A2 (2002-02)). Ambient operating temperature: 0 °C ... +50 °C. Confirm both against the site before ordering.
Yes. The official SICK data sheet for part no. 1080076 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
Compare the full type code and part number 1080076 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.