- Automation & ControlView all 1,985 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Industrial Computers
- Pneumatic Cylinders
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric XB6AS8349B XB6 Emergency Stop 16 mm 1NO+2NC
Description
XB6AS8349B: XB6 emergency stop with 30 mm red mushroom head
The XB6AS8349B is a Schneider Electric Harmony XB6 complete emergency stop push-button for a 16 mm panel hole. It has a 30 mm unmarked red mushroom head, trigger action with mechanical latching, turn-to-release reset and a contact block of one normally open and two normally closed contacts. Seven Star LLC supplies the XB6AS8349B in Oman and the GCC as an independent supplier based in Muscat.
The 16 mm size is the smaller XB6 format, used on compact panels, pendant stations and equipment where a 22 mm hole would be too large. The word complete in the datasheet title means the head and the contact block are supplied together as one reference, which avoids ordering separate parts.
Electrical ratings of the XB6AS8349B
The contacts are silver alloy (Ag/Ni). Rated operational currents are 3 A at 120 V and 1.5 A at 240 V in AC-15, and 0.22 A at 125 V and 0.1 A at 250 V in DC-13. A 6 A gG cartridge fuse is required for short-circuit protection. Insulation voltage is 250 V at pollution degree 3 and the impulse withstand is 4 kV. Electrical durability is 1000000 cycles at 230 V in AC-15 and DC-13.
The electrical reliability figure of 10 to the minus 8 at 5 V and 1 mA indicates suitability for low-level signal circuits, so the XB6AS8349B can feed a safety relay or PLC input directly. Connections are Faston tabs of 2.8 × 0.5 mm.
Latching and contact action of the XB6AS8349B
Pushing the mushroom head latches it down mechanically and opens the two normally closed contacts, which are marked (21-22) and (31-32), while the normally open contact (13-14) closes. The head stays down until it is turned to release. The datasheet lists positive opening to IEC 60947-5-1 appendix K, meaning the operator itself forces the NC contacts open, so a welded contact cannot keep the circuit closed.
The travel figures show the sequence: the NC contacts change after 1 mm, the NO contact after 2 mm, and the total stroke is 3.5 mm. The operating force at the change points is 3.5 N for the NO contact and 4.5 N for the NC contacts. Mechanical durability is 100000 cycles, a figure suited to a device that is operated rarely.
Selection checklist and RFQ information for XB6AS8349B
Send the points below so that the part number can be confirmed against the datasheet and checked for availability in one reply.
- Part number XB6AS8349B and quantity, in multiples of 1.
- Contact arrangement required: this device has 1 NO + 2 NC.
- Circuit voltage and current of the stop loop and the safety relay used.
- Panel thickness, hole size (16 mm) and rear depth on the door.
- Any safety standard or certificate that must be shown, compared with the datasheet.
- Delivery location in Oman or the GCC and the lead time you need.
Where XB6AS8349B is used in Oman and the GCC
A compact emergency stop like XB6AS8349B suits portable control pendants, small machine panels, packaged skids, conveyors, workshop equipment and lifting aids in Oman and the GCC. Because the head is a mushroom of 30 mm and the hole only 16 mm, it works where space is limited but a clear stop target is still required.
In hot and dusty plants, mount it within easy reach, keep the head visible and tested, and inspect the latch periodically as part of the maintenance plan.
Mounting and environment of the XB6AS8349B
The this unit mounts in a 16 mm hole; the dimension drawing gives a panel thickness range of 1 to 6 mm. The head measures 30 mm across, and the overall depth is 77 mm, so check the rear clearance on a shallow door. The body weighs 0.041 kg. The datasheet gives IP65 for the front, UL and CSA NEMA 4, 4X and 13 equivalents where listed, operation from -25 to 70 °C and storage from -40 to 70 °C. Shock resistance is 30 gn for 18 ms and 50 gn for 11 ms.
The mounting position is any. IP65 applies to the front when the panel seal is in good order; the rear Faston terminals must be protected inside an enclosure.
Emergency stop standards and limits of the XB6AS8349B
Among the standards named on the datasheet are IEC 60947-5-5, IEC 60204-1 and ISO 13850, the three references that govern emergency stop devices and their use on machines, as well as IEC 60947-5-1, UL 508 and CSA C22.2 No 14. The datasheet does not state a performance level or a safety-integrity rating, so the machine builder must show that the arrangement meets the risk assessment, normally by monitoring the NC contacts with a safety relay.
Use the second NC contact for redundancy or for a separate circuit, and the NO contact for a status signal to a controller. Certifications listed are CSA, CCC, GOST and UL.
Technical specifications of the XB6AS8349B
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / XB6AS8349B |
| Product type | Complete emergency stop push-button |
| Operator | Red mushroom, 30 mm, unmarked |
| Actuation / reset | Trigger action, mechanical latching; turn to release |
| Bezel material | Plastic |
| Contacts | 1 NO + 2 NC |
| Terminal marking (ISO) | (31-32)NC, (13-14)NO, (21-22)NC |
| Operating travel | 1 mm NC change; 2 mm NO change; 3.5 mm total |
| Operating force | 3.5 N (NO change); 4.5 N (NC change) |
| Mechanical durability | 100000 cycles |
| Range | Harmony XB6 |
| Mounting diameter | 16 mm |
| Contact operation | Slow-break |
| Contacts material | Silver alloy (Ag/Ni) |
| Terminals | Faston connectors, 2.8 × 0.5 mm |
| Short-circuit protection | 6 A cartridge fuse type gG |
| Rated insulation voltage [Ui] | 250 V, pollution degree 3 |
| Rated impulse withstand [Uimp] | 4 kV |
| Rated operational current | 3 A at 120 V AC-15; 1.5 A at 240 V AC-15; 0.1 A at 250 V DC-13; 0.22 A at 125 V DC-13 |
| Electrical durability | 1000000 cycles, AC-15 at 230 V and DC-13 at 230 V, up to 3600 cycles/h, load factor 0.5 |
| Electrical reliability | 10<sup>-8</sup> at 5 V and 1 mA, 90 % confidence level |
| Protective treatment | TC |
| Electrical shock protection class | Class II (IEC 61140) |
| Positive opening | Yes, per IEC 60947-5-1 appendix K |
| Degree of protection | IP65; NEMA 4, 4X, 13 |
| Operating / storage temperature | -25 to 70 °C / -40 to 70 °C |
| Shock resistance | 30 gn (18 ms); 50 gn (11 ms) |
| Dimensions (H x W x D) | 30 × 30 × 77 mm |
| Net weight | 0.041 kg |
| Certifications | CSA, CCC, GOST, UL |
| Warranty | 18 months |
Documents and quotation
The Schneider Electric datasheet for the XB6AS8349B is attached on this page for your technical file. It holds the electrical, mechanical and environmental data summarised above, together with the dimension and panel cut-out drawings.
To request a quotation, send the part number and quantity through the enquiry form and we will reply with availability and delivery terms. Seven Star LLC is an independent supplier and does not act for the manufacturer, so please check the datasheet against your project requirements before ordering.
Datasheets & Documents
- Datasheet Schneider Electric XB6AS8349B Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric XB6AS8349B XB6 Emergency Stop 16
Answers from our engineering team on installation, compatibility and integration.
01How is the XB6AS8349B released?
It latches mechanically when pushed and is released by turning the head, per the datasheet.
02What contacts does the XB6AS8349B have?
One normally open (13-14) and two normally closed (21-22, 31-32) slow-break contacts with positive opening.
03What panel hole does the XB6AS8349B need?
A 16 mm hole, with a panel thickness of 1 to 6 mm shown on the datasheet drawing.
04Does the datasheet of the XB6AS8349B give a safety rating?
No performance level or safety-integrity rating is listed, and the machine builder must justify the safety function.
05Does Seven Star LLC supply the XB6AS8349B in Oman?
Yes, as an independent supplier in Muscat serving Oman and the GCC. Send the part number and quantity and we confirm availability and documents.


















Reviews
There are no reviews yet.