Brand:

C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel

Description

Overview

The C-TEC CFP708-4 is an eight-zone conventional fire alarm control panel, LPCB certified to EN54 parts 2 and 4, and manufactured by C-TEC in the UK. It provides eight detector zone circuits and four conventional sounder circuits in an attractive flush- or surface-mountable plastic enclosure, with an intuitive user interface using colour-coded buttons and combined keypad/keyswitch entry. The panel is supplied with an integral 1.5 A EN54-4/A2 compliant switch-mode power supply and space for two 12 V VRLA backup batteries.

Engineering and Design

A wide range of engineering functions is built in, including zone test, coincidence, zone delay and non-latching zones, plus comprehensive test and fault-finding facilities. The panel includes two on-board relays (fire and fault), two open-collector outputs (remote and reset), and class change and alert inputs for integration with building management systems. Eight zone circuits support a maximum circuit length of 500 m with up to 25 detectors per zone (32 combined with manual call points), and the quiescent current draw is a low 25 mA.

The CFP708-4 operates from a 230 V 50/60 Hz mains supply with a maximum 350 mA current draw, providing an internal supply of 19-28.5 V DC (nominal 27 V) with total output current limited to 1.5 A. Two 12 V VRLA batteries (max 3.2-3.3 Ah) in series provide standby power, with a minimum battery size of 1.2 Ah. Expansion connections support up to eight two-wire repeaters (one CFP761 network card per system) and optional CFP relay boards, and the panel is fully compatible with C-TEC’s ActiV range of conventional detectors with options for EN54-13 compliant sounder circuit boards.

Key Features

  • Eight detector zone circuits and four conventional sounder circuits
  • Third-party certified to EN54 parts 2 and 4 by LPCB; EN54-13 compliance option via BSI
  • Integral 1.5 A EN54-4/A2 compliant switch-mode PSU
  • 230 V 50/60 Hz mains supply with low 25 mA quiescent current
  • Two on-board relays (fire and fault) plus two open-collector outputs (remote and reset)
  • Class change and alert inputs for BMS integration
  • Zone test, coincidence, zone delay and non-latching zone engineering functions
  • Up to 25 devices per zone (32 with call points), 500 m max zone circuit length
  • Space for two 12 V 3.3 Ah VRLA batteries in series for standby power
  • Flush or surface mount plastic enclosure with keypad/keyswitch entry
  • Expansion to eight repeaters via CFP761 network card and optional relay boards
  • Fully compatible with C-TEC ActiV range of conventional detectors

Applications

Conventional fire detection and alarm systems for offices, retail, schools, hotels, residential buildings, small industrial facilities and public buildings requiring an EN54-certified multi-zone panel.

Specifications

Zones8 detector zone circuits (500 m max per circuit)
Sounder circuits4 conventional sounder circuits
CertificationEN54 parts 2 and 4 (LPCB); EN54-13 compliance option (BSI)
Mains supply230 V AC, 50/60 Hz, 350 mA max
Internal supply19-28.5 V DC (nominal 27 V); total output limited to 1.5 A
Batteries2 x 12 V VRLA in series, max 3.3 Ah (min 1.2 Ah)
Quiescent current25 mA
Alarm voltage20 V min / 27 V max
Devices per zoneUp to 25 (32 combined with manual call points)
Outputs2 relays (fire, fault); 2 open-collector (remote, reset)
InputsClass change, alert
ExpansionUp to 8 two-wire repeaters (CFP761 card), CFP relay boards, EN54-13 sounder boards
CompatibilityC-TEC ActiV conventional detector range
EnclosurePlastic, flush or surface mount
ManufacturerC-TEC, UK

Why Seven Star LLC

Seven Star LLC supplies C-TEC fire alarm panels, detectors and accessories with verified specifications and certificates across Oman and the GCC. Our team supports panel selection, zone planning and spare parts for commercial and industrial fire detection systems.

Call To Action

Send your building layout, zone count and detector requirements to our engineering team for a quotation. Use the Inquiry Form below – we confirm the CFP708-4 configuration, batteries and pricing for your project. | Inquiry Form

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel”

Your email address will not be published.Required fields are marked *

About brand

C-TEC is a UK-based manufacturer specializing in high-quality fire alarm control panels, voice evacuation systems, and emergency communication products. With decades of engineering expertise, C-TEC has built a global reputation for designing dependable and user-friendly life safety solutions that meet international standards and certifications.

Its product range includes conventional and addressable fire alarm systems, power supplies, call systems, and assistive technology devices for hospitals, offices, and industrial facilities. C-TEC solutions are recognized for their reliability, intuitive design, and ease of installation, making them a trusted choice for critical safety applications.

Seven Star LLC supplies genuine C-TEC fire detection and safety systems, ensuring customers in the Middle East benefit from certified, efficient, and compliant solutions for protecting people, property, and industrial operations.

Frequently Asked Questions

What is the C-TEC CFP708-4?
An eight-zone conventional fire alarm control panel manufactured by C-TEC in the UK, LPCB certified to EN54 parts 2 and 4, with four conventional sounder circuits.
How many devices can connect to each CFP708-4 zone?
Up to 25 detectors per zone (32 combined with manual call points), with a maximum zone circuit length of 500 m.
What is the power supply of the CFP708-4?
230 V AC 50/60 Hz mains (350 mA max) with an integral 1.5 A EN54-4/A2 compliant switch-mode PSU and an internal supply of 19-28.5 V DC (nominal 27 V).
Does the CFP708-4 support battery backup?
Yes. Space is provided for two 12 V VRLA batteries in series (max 3.3 Ah, min 1.2 Ah) for standby power.
What outputs and expansion does the CFP708-4 offer?
Two on-board relays (fire and fault), two open-collector outputs (remote and reset), class change and alert inputs, plus expansion for up to eight two-wire repeaters (CFP761 card) and optional relay boards.