Schneider Electric RM35HZ21FM RM35-HZ frequency relay
Description
RM35HZ21FM: RM35HZ21FM frequency control relays in the Harmony range
The RM35HZ21FM is a Schneider Electric Harmony frequency control relays from the RM35 family, built to supervise overfrequency and underfrequency 50 or 60 Hz. It is powered from a separate 120–277 V AC supply, offers 1 changeover + 1 changeover output contact, and is housed in a 35 mm wide DIN-rail case. Seven Star LLC supplies the RM35HZ21FM in Oman and the GCC as an independent supplier based in Muscat.
The datasheet we reviewed is dated 8 Nov 2026. It describes a unit without a test button on the front.
Where the RM35HZ21FM is used in Oman and the GCC
Typical uses include standby and island generators, where the frequency tells you the engine is not at speed or the grid is unstable. It is also found in marine and offshore style networks and small isolated systems fed from engine-driven alternators, and in critical loads that should be disconnected or transferred when the supply drifts away from 50 or 60 Hz. Heat, dust, humidity and unstable supplies make supervision relays a low-cost way to protect larger equipment, but project specifications and local rules decide which protection is required.
Technical specifications of the RM35HZ21FM
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RM35HZ21FM |
| Relay type | Frequency control relays |
| Relay name | RM35HZ21FM |
| Monitored parameters | Overfrequency and underfrequency 50 or 60 Hz |
| Time delay type | Adjustable 0.1–10 s, ± 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum power consumption | 6 VA AC |
| Measurement range | 40–70 Hz |
| Reset time | 2000 ms time delay |
| Maximum switching voltage | 250 V AC/DC |
| [Us] rated supply voltage | 120–277 V AC |
| [Un] rated nominal voltage | 120–277 V AC, non self-powered |
| Supply voltage limits | 102–308 V AC |
| Nominal output current | 5 A |
| Maximum input frequency | 70 Hz |
| Delay at power up | 0.5 s |
| Hysteresis | 0.3 % fixed |
| Repeat accuracy | ± 0.5 % for input and measurement circuit; ± 0.5 % for time delay |
| Threshold setting | -2–10 Hz; -10–2 Hz |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation resistance | > 500 MΩ at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MΩ at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MΩ at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MΩ at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MΩ at 500 V DC between measurement and relay output conforming to IEC 60255-5; > 1 MΩ at 500 V DC between supply and measurement conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Operating voltage tolerance | – 15 % + 10 % Un |
| Operating position | Any position without derating |
| Connections – terminals | Screw terminals, 1 × 0.5–1 × 4 mm² (20 AWG–11 AWG) solid without cable end; Screw terminals, 2 × 0.5–2 × 2.5 mm² (20 AWG–14 AWG) solid without cable end; Screw terminals, 1 × 0.2–1 × 2.5 mm² (24 AWG–12 AWG) flexible with cable end; Screw terminals, 2 × 0.2–2 × 1.5 mm² (24 AWG–16 AWG) flexible with cable end |
| Tightening torque | 0.6–1 N.m conforming to IEC 60947-1 |
| Housing material | Polycarbonate |
| Local signalling | 1 LED green for power ON; 1 LED yellow for correct frequency (high R1); 1 LED yellow for correct frequency (low R2) |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Control type | Without test button |
| Standards | IEC 60255-6, NF EN 60255-6 |
| Product certifications | GL, UL, CSA, C-Tick, GOST |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Storage temperature | -40 to 70 °C |
| Operating temperature | -20 to 50 °C |
| Width | 35 mm |
| Packing | 1 piece, 126 g; 48 pieces in the second package level |
| Country of origin | Indonesia |
| Warranty | 18 months |
Output contacts and durability of the RM35HZ21FM
The output is 1 changeover + 1 changeover contact, rated 5 A nominal at up to 250 V AC/DC, with a switching capacity of 1250 VA and a minimum switching current of 10 mA at 5 V DC. The listed durability is 100000 cycles electrical and 30000000 cycles mechanical. The contacts of the RM35HZ21FM are intended for pilot duty such as contactor coils, signal lamps and PLC inputs. For larger loads use an interposing contactor and keep the relay contact for the control circuit.
Because the minimum switching current is small, the same output can also feed a low-level signal such as a PLC input, but a contact that has switched heavy inductive loads should not later be reused for low-level signals.
Installing and commissioning the RM35HZ21FM
The relay clips onto a 35 mm DIN rail. The datasheet lists the operating position as Any position without derating. Terminals are screw type: Screw terminals, 1 × 0.5–1 × 4 mm² (20 AWG–11 AWG) solid without cable end; Screw terminals, 2 × 0.5–2 × 2.5 mm² (20 AWG–14 AWG) solid without cable end. Tightening torque is 0.6–1 N.m conforming to IEC 60947-1.
Before energising the RM35HZ21FM, check the nameplate range against the supply and compare the wiring with the diagram on the datasheet and on the side of the housing. Switch on and confirm the green supply LED and the output indication. Then provoke the monitored fault in a safe way, for example by removing a fuse on a spare circuit or by simulating the condition, and confirm that the output behaves as intended.
Settings, measurement and timing of the RM35HZ21FM
The measuring range is 40–70 Hz. Thresholds are set as -2–10 Hz or -10–2 Hz. Time delay: Adjustable 0.1–10 s, ± 10 % Tt- time delay upon fault. Hysteresis is 0.3 % fixed. Reset time is listed as 2000 ms time delay.
When commissioning the RM35HZ21FM, set the thresholds against the real running values of the plant, not against the nameplate alone. Where an adjustable fault delay is available, a longer time suits starting transients and short disturbances, while a short time protects equipment faster. Note the dial positions on the commissioning sheet so the settings can be restored after maintenance.
Environment, insulation and approvals for the RM35HZ21FM
Storage is listed at -40 to 70 °C. Operation is listed at -20 to 50 °C. Relative humidity is 95 % at 55 °C conforming to IEC 60068-2-30. Protection is IP20 (terminals) conforming to IEC 60529, pollution degree 3 conforming to IEC 60664-1, rated insulation voltage 400 V conforming to IEC 60664-1. The housing is polycarbonate.
Certifications listed on the datasheet for this reference: GL, UL, CSA, C-Tick, GOST. Check the marks against your project specification, because requirements differ between sites.
In a closed panel in an Omani summer the air near the relay can be much hotter than the room, so leave space around it and keep it away from contactors and power resistors.
What the RM35HZ21FM monitors
According to the datasheet, this relay covers the following functions. Each one is explained in practical terms below.
- Overfrequency and underfrequency. The relay measures the supply frequency and releases when it moves outside the window around 50 Hz or 60 Hz. Generator sets and weak islanded networks are typical places where frequency drifts before voltage does.
Information to send with an RFQ for the RM35HZ21FM
- Exact reference RM35HZ21FM and quantity.
- Supply voltage, frequency and type of network.
- The load or machine being supervised and the required alarm or trip behaviour.
- Required contact arrangement and rating.
- Related relays, sockets or accessories needed on the same order.
- Delivery location and timeline.
Documents and quotation
The Schneider Electric datasheet for the RM35HZ21FM is attached on this page and holds the complete specification summarised above, as printed on the manufacturer’s document dated 8 Nov 2026.
Send us the reference this unit, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric RM35HZ21FM Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RM35HZ21FM RM35-HZ frequency
Answers from our engineering team on installation, compatibility and integration.
01What does the RM35HZ21FM monitor?
It is the RM35HZ21FM Harmony control relay for overfrequency and underfrequency 50 or 60 Hz. See the functions list on this page for how each one works.
02What supply and measuring range does the RM35HZ21FM have?
The datasheet lists the supply as 120...277 V AC with limits of 102…308 V AC, and a measurement range of 40...70 Hz.
03What output does the RM35HZ21FM provide?
The output is 1 C/O + 1 C/O contact, rated 5 A nominal at up to 250 V AC/DC. Electrical durability is listed as 100000 cycles and mechanical durability as 30000000 cycles.
04How is the RM35HZ21FM mounted and what size is it?
It clips onto a 35 mm DIN rail and measures 35 mm wide. Terminals are screw type, tightened to 0.6…1 N.m conforming to IEC 60947-1.
05What environment is the RM35HZ21FM rated for?
Operation is listed at -20 to 50 °C, storage at -40 to 70 degrees C, relative humidity 95 % at 55 °C conforming to IEC 60068-2-30 and protection IP20 (terminals) conforming to IEC 60529.