Schneider Electric LC2D09BD 9 A TeSys Deca Reversing Contactor
Description
LC2D09BD contactor: a pre-assembled reversing pair with 24 V DC coils
The LC2D09BD is a Schneider Electric contactor described in the datasheet as: TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 24 V DC coil. A reversing contactor lets a three-phase motor run in both directions by swapping two phases. The LC2D09BD supplies two 9 A contactors preassembled with a mechanical interlock and wired power connections, so the installer does not have to build the reversing circuit. Seven Star LLC supplies the LC2D09BD in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: LC2 indicates the reversing version of the Deca contactor, D09 the 9 A frame and BD the 24 V DC coil, as confirmed by the coil rows. The datasheet also shows one NO plus one NC auxiliary contact.
Technical specifications of the LC2D09BD
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LC2D09BD |
| Description | TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 24 V DC coil |
| Range | TeSys; TeSys Deca |
| Product name | TeSys D; TeSys Deca |
| Product or Component Type | Reversing contactor |
| Device short name | LC2D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-1; AC-3e |
| Poles description | 3P |
| power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25 to 400 Hz; Power circuit <= 300 V DC |
| [Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Motor power kW | 2.2 kW at 220 to 230 V AC 50-60 Hz; 4 kW at 380 to 400 V AC 50-60 Hz; 4 kW at 415 V AC 50-60 Hz; 4 kW at 440 V AC 50-60 Hz |
| Maximum Horse Power Rating | 0.5 hp at 115 V AC 60 Hz for 1 phase motors; 1 hp at 230/240 V AC 60 Hz for 1 phase motors; 2 hp at 200/208 V AC 60 Hz for 3 phase motors |
| Control circuit type | DC standard |
| [Uc] control circuit voltage | 24 V DC |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand | 6 kV IEC 60947 |
| Overvoltage category | III |
| [Ith] conventional free air thermal | 10 A (at 60 °C) for signalling circuit |
| current | 61 A 40 °C – 1 min for power circuit; 105 A 40 °C – 10 s for power circuit; 210 A 40 °C – 1 s for power circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand | 30 A 40 °C – 10 min for power circuit |
| Associated fuse rating | 25 A gG at <= 690 V coordination type 1 for power circuit; 20 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2.5 mOhm – Ith 25 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1 |
| Electrical durability | 0.6 Mcycles 25 A AC-1 <= 440 V; 2 Mcycles 9 A AC-3 <= 440 V; 2 Mcycles 9 A AC-3e <= 440 V |
| Power dissipation per pole | 0.2 W AC-3; 1.56 W AC-1; 0.2 W AC-3e |
| Front cover | With |
| Interlocking type | Mechanical |
| Mounting Support | Rail; Plate |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1 |
| Product Certifications | DNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA |
| Connections – terminals | Power circuit screw clamp terminals 1 1 to 4 mm²flexible without cable end |
| Operating time | 53.55 to 72.45 ms closing; 16 to 24 ms opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 30 Mcycles |
| Maximum operating rate | 3600 cyc/h 60 °C |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1 to 0.25 Uc (-40 to 70 °C):drop-out DC; 0.7 to 1.25 Uc (-40 to 60 °C):operational DC; 1 to 1.25 Uc (60 to 70 °C):operational DC |
| Time constant | 28 ms |
Power circuit and coil data of the LC2D09BD
Utilisation categories: AC-3; AC-1; AC-3e. Rated operational voltage: Power circuit <= 690 V AC 25 to 400 Hz; Power circuit <= 300 V DC. Rated operational current: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit. Motor power ratings: 2.2 kW at 220 to 230 V AC 50-60 Hz; 4 kW at 380 to 400 V AC 50-60 Hz; 4 kW at 415 V AC 50-60 Hz; 4 kW at 440 V AC 50-60 Hz. Coil voltage: 24 V DC. Coil operating limits: 0.1 to 0.25 Uc (-40 to 70 °C):drop-out DC; 0.7 to 1.25 Uc (-40 to 60 °C):operational DC; 1 to 1.25 Uc (60 to 70 °C):operational DC. Inrush coil consumption: 5.4 W 20 °C. Hold-in consumption: 5.4 W 20 °C.
Because the coil is 24 V DC, the contactor can be driven directly from a PLC output sized for the coil current, which is useful on machines with a 24 V control supply.
Why the interlock and the wiring in a reversing set matter
If the two contactors close at once the three phases short-circuit. The mechanical interlock between the two devices prevents that physically, and the pre-wired power links remove the common error of mis-wiring the reversing connections.
A good reversing control also adds an electrical interlock through the auxiliary contacts and a short delay before the reverse command so that the motor has time to decelerate. For heavy loads, take the plugging category into account: reversing from full speed is a hard duty for the contacts.
Choosing the LC2D09BD: a short selection checklist
- Motor power and current, and whether reversing is done from standstill or on the run.
- Control voltage: 24 V DC for this reference.
- Auxiliary contacts required by the interlock scheme.
- Matching thermal overload relay or motor circuit breaker.
- Whether a coil surge suppressor is already present in the datasheet.
- Panel space for the pair and the wiring kit.
Mounting, wiring and service life of the LC2D09BD
Mount on a rail, wire the supply to the upper terminals and the motor to the lower ones, and connect only the control side. Because the power circuit is pre-wired, check that the phase rotation is correct on both directions during commissioning.
Test the interlock by trying to energise both coils with the motor disconnected; neither contactor should accept the second command. Check contacts for wear at the interval set by the duty.
Where the LC2D09BD is used in Oman and the GCC
Reversing contactors are used on door and gate motors, hoists, conveyors that run both directions, valve actuators and small positioning drives in the region. Their 24 V DC coil is common in OEM machines imported to the Gulf.
Dimensions, environment and approvals of the LC2D09BD
For the LC2D09BD, plan the mounting space from the datasheet: 90 mm (W) x 77 mm (H) x 95 mm (D). The LC2D09BD weighs 1.017 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -40 to 60 °C. Ingress protection: IP20 front face IEC 60529. Operating altitude: 0 to 3000 m. Standards listed: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60335-2-40:Annex JJ; IEC 60335-1. Certifications listed for this reference: DNV; CSA; CCC; UL; GL; LROS (Lloyds register of shipping); BV; RINA; GOST; UKCA.
Information to send with an RFQ for the LC2D09BD
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric LC2D09BD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LC2D09BD 9 A TeSys Deca
Answers from our engineering team on installation, compatibility and integration.
01What is the rated current of the LC2D09BD?
Listed: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit.
02What is the coil voltage of the LC2D09BD?
The coil is rated 24 V DC.
03Is the LC2D09BD pre-interlocked?
The datasheet states: Preassembled with reversing power busbar.
04What motor power can the LC2D09BD handle?
Values: 2.2 kW at 220 to 230 V AC 50-60 Hz; 4 kW at 380 to 400 V AC 50-60 Hz; 4 kW at 415 V AC 50-60 Hz; 4 kW at 440 V AC 50-60 Hz; 5.5 kW at 500 V AC 50-60 Hz; 5.5 kW at 660 to 690 V AC 50-60 Hz.
05What auxiliary contacts has the LC2D09BD?
Listed: 1 NO + 1 NC.