Schneider Electric RPZF4 Socket for RPM4 Relays
Description
RPZF4 relay socket: what it is
RPZF4 is a 16 A mixed-contact socket for four-pole RPM power relays. In the Schneider Electric Harmony Electromechanical Relays range it belongs to the RPZ socket line, and the datasheet records the compatible relay as: Plug-in relay RPM with 4 C/O contact.
A socket like this is the part of a relay installation that outlasts relays: it carries the wiring, takes the clip-in relay and lets a failed relay be swapped without touching a single conductor. Sockets in this family look alike, so check the part number against the relay series and contact count before ordering.
Seven Star LLC supplies RPZF4 in Oman and the GCC as an independent industrial supplier in Muscat; the datasheet we hold is dated 8 Nov 2026.
Wiring and terminal details
The datasheet lists these conductor sizes for RPZF4: – screw clamp terminals, flexible cable with cable end 1 × 0.5–1 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 1 × 0.5–1 × 1.5 mm² / 20 AWG–16 AWG – screw clamp terminals, flexible cable with cable end 2 × 0.5–2 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 2 × 0.5–2 × 1.5 mm² / 20 AWG–16 AWG. Tighten to the value stated, which is < 1 N.m for M3.5 screw(s), and use ferrules on stranded wire in line with the flexible-with-cable-end entries.
The contact terminal arrangement is described as mixed and the pin shape as flat. That pin shape must match the relay, so the extra width compared with the two-pole socket needs to be planned on the rail.
Installation and maintenance notes
RPZF4 can be fixed by panel screws or clipped onto a 35 mm symmetrical rail. The listed ambient range is -40–55 °C for operation and -40–85 °C for storage; IP20 on the socket means it belongs inside an enclosure.
Good practice is to identify each socket on the panel drawing, retorque terminals after the first thermal cycle, and inspect for discoloured terminals at routine shutdowns. A failed relay is replaced by unplugging it; the socket stays wired, which keeps downtime short.
Relays and parts that go with RPZF4
This is the four-contact member of the RPZ socket line. Two-pole relays such as RPM22BD and RPM22P7 use the narrower RPZF2 socket instead, so check the contact count of the relay first.
For reference, the compatibility entry in the RPZF4 datasheet reads: Plug-in relay RPM with 4 C/O contact. Where a project needs a time function, the RUW101MW multifunction timer module lists sockets of the RPZ and RUZ lines as compatible; check its own datasheet for the exact sockets that apply.
RPZF4 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / RPZF4 |
| Product type | Socket for plug-in relay (RPM series) |
| Compatible relays | Plug-in relay RPM with 4 C/O contact |
| Contacts | 4 C/O |
| Thermal current (free air) | 16 A |
| Rated operational voltage | < 250 V |
| Contact terminal arrangement | Mixed |
| Pin shape | Flat |
| Terminals | – screw clamp terminals, flexible cable with cable end 1 × 0.5–1 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 1 × 0.5–1 × 1.5 mm² / 20 AWG–16 AWG – screw clamp terminals, flexible cable with cable end 2 × 0.5–2 × 2.5 mm² / 20 AWG–14 AWG – screw clamp terminals, solid cable without cable end 2 × 0.5–2 × 1.5 mm² / 20 AWG–16 AWG |
| Tightening torque | < 1 N.m for M3.5 screw(s) |
| Fixing | By screw (panel); Clip-on (35 mm symmetrical DIN rail) |
| Impulse withstand | 4 kV |
| Overvoltage category / pollution degree | III / 3 |
| Width / net weight | 50 mm / 0.094 kg |
| Sold in multiples of | 10 |
| Protection | IP20 conforming to IEC 60529 |
| Standard | IEC 61984 |
| Certifications | UL; CSA |
| Operating / storage temperature | -40–55 °C / -40–85 °C |
Typical use of RPZF4 in Oman and the GCC
Typical uses are multi-contact switching where one relay must handle several circuits at once, such as interlocks, status feedback and load control in the same enclosure. Such panels are found in power stations, desalination plants, oil and gas facilities and building services across Oman, usually in air-conditioned rooms or sealed cabinets.
The datasheet limits operation to -40–55 °C and lists pollution degree 3 and overvoltage category III; heat build-up in sun-exposed enclosures and dust ingress through poor cable entries are the practical risks to design around.
Socket family comparison
| Socket | Relay | Thermal current | Width |
|---|---|---|---|
| RPZF2 | RPM 2 C/O | 16 A | 30 mm |
| RPZF4 (this page) | RPM 4 C/O | 16 A | 50 mm |
| RSZE1S48M | RSB 2 C/O | 10 A | 15.5 mm |
| RUZC3M | RUM 3 C/O | 10 A | 38 mm |
| RUZSC3M | RUM 3 C/O | 12 A | 36 mm |
Information to send with an RFQ
To quote correctly we need:
- Part number RPZF4 and the quantity.
- The relay part number that will sit in the socket.
- Wire size, ferrule use and panel or rail mounting.
- Delivery location in Oman or the GCC and any project reference.
Selection and ordering checklist for RPZF4
Confirm the following before you order this unit:
- The relay type and contact count must match: this socket is for 4 C/O RPM relays.
- Current: the datasheet gives 16 A conventional free-air thermal current and operational voltage < 250 V.
- Width on the rail: 50 mm; net weight 0.094 kg.
- Wire sizes and whether ferrules are fitted, against the terminal table above.
- Packaging: the datasheet shows a sale quantity of 10, so confirm how many you need.
Documents and quotation
The datasheet for this unit is attached to this page (document dated 8 Nov 2026). Please treat it as the reference for every figure above, and tell us if your project specification asks for anything the datasheet does not state.
Send the part number, quantity, required delivery point and any project reference through the quotation form or by email. Seven Star LLC is an independent industrial supplier based in Muscat, serving customers across Oman and the GCC, and we reply with availability and lead time for this exact part number.
Other Models in the Schneider Harmony Rpm Socket Range
Seven Star LLC supplies models from the Schneider Harmony Rpm Socket range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric RPZF2 Socket for RPM2 Relays | Contactors & Overload Relays | View details |
| Schneider Electric RPZF4 Socket for RPM4 Relays | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric RPZF4 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric RPZF4 Socket for RPM4 Relays
Answers from our engineering team on installation, compatibility and integration.
01Which relays fit RPZF4?
The datasheet lists Plug-in relay RPM with 4 C/O contact. Always match the relay series and contact count.
02What current is RPZF4 rated for?
The conventional free-air thermal current is 16 A, with rated operational voltage < 250 V.
03How is RPZF4 mounted?
By panel screws or clip-on to a 35 mm symmetrical DIN rail; it is 50 mm wide.
04What terminals does RPZF4 use?
Screw terminals with the conductor sizes shown in the specification table; tightening torque is < 1 N.m for M3.5 screw(s).
05What temperature range applies to RPZF4?
Operation -40–55 °C, storage -40–85 °C; protection is IP20.