Schneider Electric LC1E0910M5 9 A 220 V AC Contactor

Description

LC1E0910M5: 9 A AC-3, 220 V AC coil EasyPact TVS contactor

The LC1E0910M5 is a Schneider Electric contactor described in the datasheet as: EasyPact TVS contactor 3P(3 NO) – AC-3 – <= 440 V 9A – 220 V AC coil. It belongs to the Easy TeSys control range and is a three-pole device for switching motors and resistive loads. Seven Star LLC supplies the LC1E0910M5 in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: LC1E is the contactor family; the digits correspond to the 9 A AC-3 rating shown in the datasheet title, and the suffix gives the control coil, which the datasheet states as 220 V AC 50 Hz. A 220 V AC coil lets this contactor sit directly on a single-phase control circuit derived from phase and neutral of a 380/220 V supply, without any transformer. The 9 A rating suits small pumps, fans and auxiliary motors.

Technical specifications of the LC1E0910M5

Parameter Specification
Manufacturer / part number Schneider Electric / LC1E0910M5
Description EasyPact TVS contactor 3P(3 NO) – AC-3 – <= 440 V 9A – 220 V AC coil
Range Easy TeSys Control
Product or component type Contactor
Device short name LC1E
Contactor application Motor control; Resistive load
Utilisation category AC-3; AC-3e; AC-1
Poles description / contact composition 3P / 3 NO
Rated operational voltage [Ue] Power circuit: <= 690 V AC 50/60 Hz
Rated operational current [Ie] 9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit; 9 A (at <55 °C) at <= 440 V AC AC-3e for power circuit; 25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
Control circuit voltage [Uc] 220 V AC 50 Hz
Control circuit voltage limits 0.85 to 1.1 Uc (-5 to 55 °C):operational 50 Hz; 0.3 to 0.6 Uc (-5 to 55 °C):drop-out 50 Hz
Motor power 2.2 kW at 220/230 V AC 50/60 Hz; 4 kW at 380/400 V AC 50/60 Hz; 4 kW at 415/440 V AC 50/60 Hz; 4 kW at 500 V AC 50/60 Hz; 4 kW at 660/690 V AC 50/60 Hz; 5.5 kW at 660 to 690 V AC 50/60 Hz
Making capacity (Irms) 117 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 76.5 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 20 A gG at <= 690 V coordination type 1 for power circuit; 10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Power dissipation per pole 0.2 W AC-3; 1.6 W AC-1
Inrush / hold-in power 95 VA 50 Hz cos phi 0.75 (at 20 °C); 95 VA 60 Hz cos phi 0.75 (at 20 °C) | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C); 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Mechanical durability 10000000 cycles
Electrical durability 1400000 cycles AC-3; 150000 cycles AC-1
Operating time 12 to 22 ms on closing; 4 to 19 ms on opening
Maximum operating rate 1800 cyc/h 60 °C
Auxiliary contact composition 1 NO
Tightening torque Power circuit: 1.2 N.m; Control circuit: 1.2 N.m
Mounting support Plate; DIN rail
Dimensions (W x H x D) 45 mm x 74 mm x 80 mm
Net weight 0.3 kg
IP degree of protection IP2X conforming to IEC 60529
Ambient air temperature around the device -5 to 55 °C operation; -60 to 80 °C storage
Altitude 3000 m without derating
Product certifications CB Scheme; CCC; CE; EAC; BIS
Standards EN/IEC 60947-1; EN/IEC 60947-4-1; EN/IEC 60947-5-1; GB/T 14048.1; GB/T 14048.4; GB/T 14048.5; EN/IEC 60335-1:Clause 30.2; EN/IEC 60335-2-40:Annex JJ; IS/IEC 60947-1; IS/IEC 60947-4-1; IS/IEC 60947-5-1

Coil supply, inrush and drop-out of the LC1E0910M5

The coil is rated 220 V AC 50 Hz. The datasheet gives the operating window as 0.85 to 1.1 Uc and the drop-out as 0.3 to 0.6 Uc, which translates here to operation between 187 and 242 V and drop-out between 66 and 132 V. Control-circuit designers should check that voltage drop over long cable runs and during motor starting still leaves the coil above the pick-up limit.

At 50 Hz the inrush is 95 VA and the hold-in is 8.3 VA, which at the rated voltage is about 0.43 A and 0.038 A respectively. These are the figures a control transformer or PLC output must carry, and the datasheet operating times are 12 to 22 ms on closing; 4 to 19 ms on opening, so closing and opening are quick events compared with the run-up of the motor.

Power circuit ratings of the LC1E0910M5

For motor duty the datasheet lists AC-3 at 9 A and AC-3e at 9 A at up to 440 V AC (below 55 °C), and 25 A in AC-1 for resistive loads. The motor powers stated are 2.2 kW at 220/230 V, 4 kW at 380/400 V, and 4 kW at 660/690 V (with 5.5 kW listed at 660 to 690 V). The rated operational voltage of the power circuit is up to 690 V AC at 50/60 Hz.

Short-circuit data matter for coordination: the making capacity is 117 A, the breaking capacity is 76.5 A at 440 V, and the associated fuse for type 1 coordination is 20 A gG. Per-pole dissipation is 0.2 W AC-3; 1.6 W AC-1, and the average contact impedance is 2.5 mOhm, so heating in a closed panel can be estimated from these figures.

Selection checklist for the LC1E0910M5

  • Motor current: compare the nameplate current with 9 A (AC-3) and, if the motor is high efficiency, with the AC-3e value of 9 A.
  • Coil voltage: the control supply must be 220 V AC 50 Hz; the limits are 187 to 242 V.
  • Overload protection: add a thermal overload relay or motor circuit breaker sized to the motor; the contactor itself does not give overload protection.
  • Short-circuit protection: the datasheet quotes 20 A gG for type 1 coordination.
  • Space: 45 mm wide, 74 mm high and 80 mm deep, 0.3 kg.
  • Status: say whether you need a spare for an existing starter or a new installation.

Where the LC1E0910M5 sits in the LC1E range

The table compares the LC1E0910M5 with the nearest references of the same family from the datasheets, so that size, coil and body can be chosen together.

Reference AC-3 current Motor power at 380/400 V Coil Auxiliary contact Width x height x depth
LC1E0910B5 9 A 4 kW 24 V AC 1 NO 45 mm x 74 mm x 80 mm
LC1E0910M5 9 A 4 kW 220 V AC 1 NO 45 mm x 74 mm x 80 mm
LC1E0910U5 9 A 4 kW 240 V AC 1 NO 45 mm x 74 mm x 80 mm
LC1E1210M5 12 A 5.5 kW 220 V AC 1 NO 45 mm x 74 mm x 80 mm

Practical notes on choosing the LC1E0910M5

Confirm the actual control voltage on site: 220, 230 and 240 V circuits are not the same, and the coil operating window of 0.85 to 1.1 Uc defines how much deviation the contactor tolerates.

Contactors are often replaced under time pressure, so the safest approach is to read the full reference, the coil voltage and the frame from the old device and compare with the figures above. If the data on the nameplate and the datasheet disagree, send us the details and we will help to clarify before an order is placed.

Temperature, protection and certificates of the LC1E0910M5

The LC1E0910M5 is rated for -5 to 55 °C in operation and -60 to 80 °C in storage, with altitude up to 3000 m without derating. Protection is IP2X conforming to IEC 60529, so the device needs to be inside an enclosure. Mounting is on Plate or DIN rail. In Oman the upper limit of 55 °C is the figure to check against the real panel temperature in summer, because a closed panel in the sun can run far above the outdoor air.

Certifications listed for this reference are CB Scheme; CCC; CE; EAC; BIS. Only these should be assumed; if a project requires another approval, send the requirement and we will check it against the datasheet.

Information to send with an RFQ for the LC1E0910M5

  • Full reference LC1E0910M5 and the quantity required
  • Motor nameplate data or load description
  • Control circuit voltage and frequency
  • Required delivery location and timing
  • Whether it is a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Lc1e Range

Seven Star LLC supplies models from the Se Lc1e range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LC1E0910B5 EasyPact TVS 9 A 24 V AC ContactorContactors & Overload RelaysView details
Schneider Electric LC1E0910M5 9 A 220 V AC ContactorContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric LC1E0910M5 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LC1E0910M5 9 A 220 V AC Contactor

Answers from our engineering team on installation, compatibility and integration.

01What AC-3 current does the LC1E0910M5 carry?
The datasheet lists 9 A in AC-3 and 9 A in AC-3e at up to 440 V AC, below 55 °C, and 25 A in AC-1.
02What coil voltage does the LC1E0910M5 use?
The control circuit voltage is 220 V AC 50 Hz, with an operating window of 0.85 to 1.1 Uc (187 to 242 V).
03Does the LC1E0910M5 have an auxiliary contact?
Yes, the datasheet lists an auxiliary contact composition of 1 NO. Additional blocks are not part of this reference.
04What are the dimensions and weight of the LC1E0910M5?
The datasheet gives 45 mm wide, 74 mm high and 80 mm deep, and a net weight of 0.3 kg.
05What ambient temperature is the LC1E0910M5 rated for?
The datasheet gives -5 to 55 °C for operation and -60 to 80 °C for storage, with operation up to 3000 m without derating.