ATV930D11N4 Altivar Process ATV930 drive: what the part number tells you

The ATV930D11N4 is a Schneider Electric Altivar Process ATV930 variable speed drive. The datasheet describes it as: Variable Speed Drive, Altivar Process ATV900, ATV930, 11kW, 400 to 480V, with braking unit, IP21. The ATV930 sits in the Altivar Process family for process and utilities applications and is specified by power class and by the supply and duty ratings shown below. Seven Star LLC supplies the ATV930D11N4 in Oman and the GCC as an independent supplier based in Muscat.

Reading the code against the datasheet: the ATV930 prefix is the range; the rating characters match the 11.0 kW normal duty; 7.5 kW heavy duty motor power and 23.5 A output current stated in the datasheet; N4 corresponds to the three-phase 400 V class, matching the listed supply of 380 to 480 V. Always confirm any variant by the complete reference, because neighbouring references differ in power class, format or options.

Technical specifications of the ATV930D11N4

Parameter Specification
Manufacturer / part number Schneider Electric / ATV930D11N4
Description Variable Speed Drive, Altivar Process ATV900, ATV930, 11kW, 400 to 480V, with braking unit, IP21
Range Altivar Process ATV900
Application Process for industrial
Variant Standard version; With braking chopper
Mounting mode Wall mount
Supply phases 3 phase
Rated supply voltage 380 to 480 V
Supply frequency 50-60 Hz
Nominal output current 23.5 A
Motor power 11.0 kW normal duty; 7.5 kW heavy duty
Continuous output current 23.5 A 4 kHz normal duty; 16.5 A 4 kHz heavy duty
Line current 19.8 A 380 V normal duty; 14.1 A 380 V heavy duty; 17.0 A 480 V normal duty; 12.5 A 480 V heavy duty
Maximum transient current 28.2 A 60 s normal duty; 24.8 A 60 s heavy duty
Switching frequency 2 to 16 kHz adjustable; 4 to 16 kHz with derating factor
Nominal switching frequency 4 kHz
Asynchronous motor control Variable torque standard
Brake chopper integrated True
EMC filter Integrated; With EMC plate option
Degree of protection IP21
Communication protocol EtherNet/IP; Modbus serial; Modbus TCP
Discrete inputs 10
Discrete outputs 2
Analogue inputs 3
Analogue outputs 2
Relay outputs 3
Safe torque off (STO) Yes
Prospective line Isc 50 kA
Dimensions 171 mm (W) x 409 mm (H) x 236 mm (D)
Net weight 7.7 kg
Operating temperature -15 to 50 °C (without derating)
Product certifications UL; TÜV; CSA
Standards UL 508C; IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1

How the ATV930D11N4 controls the motor

A frequency converter rectifies the incoming AC supply, stores energy on a DC bus and re-creates a three-phase output of adjustable frequency and voltage. For the ATV930D11N4 the datasheet lists a switching frequency of 2 to 16 kHz adjustable; 4 to 16 kHz with derating factor with a nominal value of 4 kHz. Higher switching frequency reduces audible motor noise but increases drive losses, which is why the datasheet notes derating at the upper end.

Motor control is selected by software profile. The datasheet lists Variable torque standard for asynchronous motors. Choosing the profile that matches the load is more important than chasing maximum dynamic performance: a centrifugal pump or fan is normally best served by a variable-torque or energy-saving profile, while conveyors and mixers usually need constant-torque behaviour with enough overload margin.

Where the ATV930D11N4 fits in a control system

Control wiring on the ATV930D11N4 follows the I/O count in the datasheet: 10 discrete inputs, 2 discrete outputs, 3 analogue inputs, 2 analogue output(s) and 3 relay output(s). Communication is by EtherNet/IP; Modbus serial; Modbus TCP.

Related parts in the same family are sold by power rating, so siblings of the ATV930D11N4 in the ATV930 series differ mainly in kW, current and enclosure size rather than in functions. This 11 kW version includes the integrated braking chopper listed in the datasheet.

Selection and ordering checklist for the ATV930D11N4

  • Motor nameplate: rated power, rated current, voltage and pole count. Size the drive on motor current, not only on kW; the 23.5 A output current of the ATV930D11N4 is the figure to compare.
  • Duty class: confirm whether the load is normal duty or heavy duty, because the datasheet gives separate ratings where both exist.
  • Supply: confirm the network matches 380 to 480 V and the frequency, and compare prospective short-circuit current with the 50 kA limit.
  • Enclosure: the drive has IP21; if the cabinet is dusty or wet, plan the enclosure and filtering accordingly.
  • Fieldbus: choose the option card, if one is needed, before ordering and note it in the enquiry.
  • Safety: the datasheet lists the safety functions fitted; compare them with your machine risk assessment.

Installation, commissioning and maintenance of the ATV930D11N4

Mount the drive in the position the datasheet specifies (vertical, within a small tilt tolerance), leave the ventilation space given in the installation manual and keep the ambient inside the range -15 to 50 °C (without derating). Oman cabinets that sit near the upper limit in summer need either derating, forced ventilation or an air-conditioned electrical room. Dimensions of this unit are 171 mm (W) x 409 mm (H) x 236 mm (D) and its net weight is 7.7 kg, which helps when checking cabinet layouts.

Commission in a fixed order: verify supply and motor cabling, run the auto-tuning or enter motor data, set ramps and limits, then configure I/O and communication. Keep a saved parameter file of the final configuration; it shortens replacement time if the unit is ever swapped. Periodic work is simple: clean the heat sink and fan path, check terminal tightness, review fault history and replace fans when the maintenance schedule calls for it.

Typical applications of the ATV930D11N4 in Oman and the GCC

Typical uses are demanding process machines, crane-type and high-dynamic duties as well as pumps and fans where the process range is specified. In Oman and across the GCC the drive meets heat, dust and humidity in water-treatment and desalination plants, oil and gas utilities, district cooling, food factories and general manufacturing. For coastal or sandy sites the cabinet design, filtering and temperature margin decide reliability at least as much as the drive itself.

Information to send with an RFQ for the ATV930D11N4

  • Full reference (ATV930D11N4) and quantity
  • Motor nameplate data and load type
  • Supply voltage and frequency, and site altitude and ambient temperature
  • Fieldbus and any accessory or option cards
  • Required delivery location and timing

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric ATV930D11N4 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ATV930D11N4 11 kW Process Drive

Answers from our engineering team on installation, compatibility and integration.

01What motor power is the ATV930D11N4 rated for?
The datasheet lists 11.0 kW normal duty; 7.5 kW heavy duty with a nominal output current of 23.5 A. Always size against the motor nameplate current as well as kW.
02What supply does the ATV930D11N4 need?
The rated supply voltage is 380...480 V. Compare it with the site network and the short-circuit current limit before installation.
03What communication does the ATV930D11N4 support?
It lists EtherNet/IP; Modbus serial; Modbus TCP on board. Option modules are described in the datasheet and are ordered separately.
04What degree of protection does the ATV930D11N4 have?
The datasheet lists IP21. Dust or moisture exposure needs a suitable cabinet around the drive.
05Does the ATV930D11N4 have safe torque off?
Yes, the datasheet lists the STO safety function.