- Automation & ControlView all 1,652 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Schneider Electric
Schneider Electric ATV630D75N4 75 kW Process Drive
Description
ATV630D75N4 Altivar Process ATV630 drive: what the part number tells you
The ATV630D75N4 is a Schneider Electric Altivar Process ATV630 variable speed drive. The datasheet describes it as: Variable Speed Drive, Altivar Process ATV600, ATV630, 75kW, 100hp, 380 to 480V, IP21, UL type 1. The ATV630 belongs to the Altivar Process ATV600 range, aimed at process and utilities applications, with Ethernet-based Modbus TCP, an integrated EMC filter and STO safety function. Seven Star LLC supplies the ATV630D75N4 in Oman and the GCC as an independent supplier based in Muscat.
Reading the code against the datasheet: the ATV630 prefix is the range; the rating characters match the 75 kW normal duty; 55 kW heavy duty motor power and 145.0 A output current stated in the datasheet; N4 corresponds to the three-phase 400 V class, matching the listed supply of 380 to 480 V. Always confirm any variant by the complete reference, because neighbouring references differ in power class, format or options.
Technical specifications of the ATV630D75N4
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / ATV630D75N4 |
| Description | Variable Speed Drive, Altivar Process ATV600, ATV630, 75kW, 100hp, 380 to 480V, IP21, UL type 1 |
| Range | Altivar Process ATV600 |
| Application | Process and utilities |
| Variant | Standard version |
| Mounting mode | Wall mount |
| Supply phases | 3 phase |
| Rated supply voltage | 380 to 480 V |
| Supply frequency | 50 to 60 Hz (tolerance -5 % / +5 %) |
| Nominal output current | 145.0 A |
| Motor power | 75 kW normal duty; 55 kW heavy duty |
| Maximum horse power rating | 100 hp normal duty; 75 hp heavy duty |
| Continuous output current | 145 A 2.5 kHz normal duty; 106 A 2.5 kHz heavy duty |
| Line current | 131.3 A 380 V normal duty; 112.7 A 480 V normal duty; 98.9 A 380 V heavy duty; 86.9 A 480 V heavy duty |
| Maximum transient current | 159.5 A 60 s normal duty; 159 A 60 s heavy duty |
| Output frequency | 0.1 to 500 Hz |
| Switching frequency | 2.5 to 8 kHz with derating factor; 2 to 8 kHz adjustable |
| Nominal switching frequency | 2.5 kHz |
| Asynchronous motor control | Constant torque standard |
| EMC filter | Integrated 150 m IEC 61800-3 category C3 |
| Degree of protection | IP21 IEC 61800-5-1; IP21 IEC 60529 |
| Communication protocol | Ethernet; Modbus serial; Modbus TCP |
| Option cards | Slot A communication module, Profibus DP V1; Slot A communication module, PROFINET; Slot A communication module, DeviceNet; Slot A communication module, Modbus TCP/EtherNet/IP; Slot A communication module, CANopen daisy chain RJ45 |
| Discrete inputs | 8 |
| Discrete outputs | 0 |
| Analogue inputs | 3 |
| Analogue outputs | 2 |
| Relay outputs | 3 |
| Safe torque off (STO) | Yes |
| Prospective line Isc | 50 kA |
| Dimensions | 290 mm (W) x 922 mm (H) x 323 mm (D) |
| Net weight | 58 kg |
| Operating temperature | -15 to 50 °C (without derating) |
| Product certifications | CSA; ATEX zone 2/22; TÜV; ATEX INERIS; UL; DNV-GL |
| Standards | UL 508C; IEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
How the ATV630D75N4 controls the motor
A frequency converter rectifies the incoming AC supply, stores energy on a DC bus and re-creates a three-phase output of adjustable frequency and voltage. For the ATV630D75N4 the datasheet lists a switching frequency of 2.5 to 8 kHz with derating factor; 2 to 8 kHz adjustable with a nominal value of 2.5 kHz. Higher switching frequency reduces audible motor noise but increases drive losses, which is why the datasheet notes derating at the upper end.
Motor control is selected by software profile. The datasheet lists Constant torque standard for asynchronous motors. Choosing the profile that matches the load is more important than chasing maximum dynamic performance: a centrifugal pump or fan is normally best served by a variable-torque or energy-saving profile, while conveyors and mixers usually need constant-torque behaviour with enough overload margin.
Where the ATV630D75N4 fits in a control system
Control wiring on the ATV630D75N4 follows the I/O count in the datasheet: 8 discrete inputs, 0 discrete outputs, 3 analogue inputs, 2 analogue output(s) and 3 relay output(s). Communication is by Ethernet; Modbus serial; Modbus TCP. Optional modules listed: Slot A communication module, Profibus DP V1; Slot A communication module, PROFINET; Slot A communication module, DeviceNet; Slot A communication module, Modbus TCP/EtherNet/IP; Slot A communication module, CANopen daisy chain RJ45; Slot A communication module, CANopen SUB-D 9; Slot A communication module, CANopen screw terminals; Slot A/slot B digital and analog I/O extension module.
Related parts in the same family are sold by power rating, so siblings of the ATV630D75N4 in the ATV630 series differ mainly in kW, current and enclosure size rather than in functions. At 75 kW this is a large wall-mounted frame of the ATV630 range, for big pumps, fans and compressors.
Selection and ordering checklist for the ATV630D75N4
- Motor nameplate: rated power, rated current, voltage and pole count. Size the drive on motor current, not only on kW; the 145.0 A output current of the ATV630D75N4 is the figure to compare.
- Duty class: confirm whether the load is normal duty or heavy duty, because the datasheet gives separate ratings where both exist.
- Supply: confirm the network matches 380 to 480 V and the frequency, and compare prospective short-circuit current with the 50 kA limit.
- Enclosure: the drive has IP21 IEC 61800-5-1; IP21 IEC 60529; if the cabinet is dusty or wet, plan the enclosure and filtering accordingly.
- Fieldbus: choose the option card, if one is needed, before ordering and note it in the enquiry.
- Safety: the datasheet lists the safety functions fitted; compare them with your machine risk assessment.
Installation, commissioning and maintenance of the ATV630D75N4
Mount the drive in the position the datasheet specifies (vertical, within a small tilt tolerance), leave the ventilation space given in the installation manual and keep the ambient inside the range -15 to 50 °C (without derating). Oman cabinets that sit near the upper limit in summer need either derating, forced ventilation or an air-conditioned electrical room. Dimensions of this unit are 290 mm (W) x 922 mm (H) x 323 mm (D) and its net weight is 58 kg, which helps when checking cabinet layouts.
Commission in a fixed order: verify supply and motor cabling, run the auto-tuning or enter motor data, set ramps and limits, then configure I/O and communication. Keep a saved parameter file of the final configuration; it shortens replacement time if the unit is ever swapped. Periodic work is simple: clean the heat sink and fan path, check terminal tightness, review fault history and replace fans when the maintenance schedule calls for it.
Typical applications of the ATV630D75N4 in Oman and the GCC
Typical uses are process and utility duties: centrifugal pumps, fans, compressors and water-treatment lines running on a wall-mounted IP21 drive. In Oman and across the GCC the drive meets heat, dust and humidity in water-treatment and desalination plants, oil and gas utilities, district cooling, food factories and general manufacturing. For coastal or sandy sites the cabinet design, filtering and temperature margin decide reliability at least as much as the drive itself.
Information to send with an RFQ for the ATV630D75N4
- Full reference (ATV630D75N4) and quantity
- Motor nameplate data and load type
- Supply voltage and frequency, and site altitude and ambient temperature
- Fieldbus and any accessory or option cards
- Required delivery location and timing
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Atv630 Range
Seven Star LLC supplies models from the Se Atv630 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric ATV630D75N4 75 kW Process Drive | AC Drives | You are viewing this model |
| Schneider Electric ATV630D22N4 22 kW Process Drive | AC Drives | View details |
Datasheets & Documents
- Datasheet Schneider Electric ATV630D75N4 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric ATV630D75N4 75 kW Process Drive
Answers from our engineering team on installation, compatibility and integration.
01What motor power is the ATV630D75N4 rated for?
The datasheet lists 75 kW normal duty; 55 kW heavy duty with a nominal output current of 145.0 A. Always size against the motor nameplate current as well as kW.
02What supply does the ATV630D75N4 need?
The rated supply voltage is 380...480 V. Compare it with the site network and the short-circuit current limit before installation.
03What communication does the ATV630D75N4 support?
It lists Ethernet; Modbus serial; Modbus TCP on board. Option modules are described in the datasheet and are ordered separately.
04What degree of protection does the ATV630D75N4 have?
The datasheet lists IP21 IEC 61800-5-1; IP21 IEC 60529. Dust or moisture exposure needs a suitable cabinet around the drive.
05Does the ATV630D75N4 have safe torque off?
Yes, the datasheet lists the STO safety function.


















Reviews
There are no reviews yet.