Schneider Electric ATS01N112FT Altistart 01 Soft Starter 12 A

Description

ATS01N112FT: Altistart 01 soft starter, 12 A

The ATS01N112FT is a compact Schneider Electric Altistart 01 soft starter for asynchronous motors in simple machines. It is rated 12 A, uses a voltage-ramp start with an integrated bypass, and is only 45 mm wide, so it sits on a 35 mm DIN rail or on screws. This unit accepts a wide 110–480 V supply and offers three control voltages (110 V AC, 24 V AC/DC or 240 V AC), which makes one unit usable across several sites. Seven Star LLC supplies the ATS01N112FT in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference against the datasheet: the compatibility code is ATS01N1, the digits 112 line up with the 12 A starter rating, and the ending FT goes with the 110–480 V multi-voltage version. That is our interpretation, not a published ordering key.

Mounting, wiring and environment for the ATS01N112FT

The unit measures 124 × 45 × 131 mm and weighs 0.28 kg. It mounts on a 35 mm rail or with screws using retractable fixings, vertically within ± 10 degrees. Power terminals take 1 to 10 mm² rigid (tightening torque 1.9 to 2.5 N.m) and control terminals 0.5 to 2.5 mm² (0.5 N.m). The degree of protection is IP20, so mount it in an enclosure.

The temperature range is −10 to 40 °C without derating and up to 50 °C at 2 % per degree. Above 1000 m the current derates 2.2 % per additional 100 m. Relative humidity is 5 to 95 % without condensation, and vibration, shock and EMC data (emissions class B per CISPR 11) are listed. Certifications named are C-Tick, CCC, UL, CSA and GOST, with CE marking.

How the ATS01N112FT starts the motor

This starter raises the motor voltage along a ramp, which cuts the inrush and the starting torque shock compared with a direct-on-line start. The datasheet gives the starting torque as 30 to 80 % of the torque the motor would produce connected straight to the line, and the output voltage never exceeds the supply voltage. Once the ramp ends the integrated bypass takes the current, which is why the dissipation at full load is only 1 W while the transient state, at 61 W, is far higher. Current consumption at nominal load is listed as 60 A.

The starting time is adjustable from 1 to 5 s. The datasheet lists no deceleration time for this version, so it is a soft start only; choose a soft-stop version if the load needs a controlled stop.

Motor ratings of the ATS01N112FT

The datasheet lists these motor powers for this starter: 1.5 kW single-phase at 230 V; 2.2 kW three-phase at 230 V; 5.5 kW three-phase at 400 V. The power ranges quoted are 1.1–2 kW at 200–240 V single-phase; 2.2–3 kW at 200–240 V three-phase; 4–6 kW at 380–440 V three-phase. The wide supply range lets one type serve both 230 V and 400 V motors, with the starter current rating as the real limit. Always compare motor full-load current with the 12 A rating rather than relying on kW alone.

Technical specifications of the ATS01N112FT

Parameter Specification
Manufacturer / part number Schneider Electric / ATS01N112FT
Range of product Altistart 01
Application Simple machine; asynchronous motors
Starter rating (IcL) 12 A
Utilisation category AC-53B per EN/IEC 60947-4-2
Supply voltage 110–480 V (−10 / +10 %)
Supply voltage limits 99–528 V
Supply frequency 50–60 Hz ± 5 %
Motor power 1.5 kW single-phase at 230 V; 2.2 kW three-phase at 230 V; 5.5 kW three-phase at 400 V
Current consumption 60 A at nominal load
Power dissipation 1 W at full load, 61 W in transient state
Type of start Voltage ramp; starting torque 30–80 % of direct-on-line value
Starting time Adjustable 1–5 s
Control circuit 110 V AC / 35 mA; 24 V AC/DC / 30 mA; 240 V AC / 80 mA
Bypass Integrated
Dimensions (H x W x D) 124 × 45 × 131 mm
Net weight 0.28 kg
Degree of protection IP20; pollution degree 2
Operating temperature −10 to 40 °C; 40 to 50 °C with 2 % derating per °C
Altitude Up to 1000 m; above that 2.2 % derating per 100 m

Control and signalling on the ATS01N112FT

The control circuit is selectable between 110 V AC (35 mA), 24 V AC/DC (30 mA) and 240 V AC (80 mA), and the datasheet shows a control sequence with pushbuttons, protection fuses and a line contactor. Two LEDs, green and yellow, show the status. The discrete output rating is 2 A for DC-13 and 3 A for AC-15.

This version has no logic inputs or relay outputs listed in the datasheet, which keeps wiring to a minimum and is the point of the simple-machine range.

ATS01N112FT compared with other Altistart 01 ratings

Reference Rating Supply Height Weight
ATS01N112FT 12 A 110–480 V (−10 / +10 %) 124 mm 0.28 kg
ATS01N125FT 25 A 110–480 V (−10 / +10 %) 124 mm 0.35 kg
ATS01N209QN 9 A 380–415 V (−10 / +10 %) 124 mm 0.42 kg
ATS01N232QN 32 A 380–415 V (−10 / +10 %) 154 mm 0.56 kg

The N1 versions share the multi-voltage supply and the three control voltages, while the QN versions are three-phase 380–415 V with built-in control supply and soft stop. The ATSU01N232LT from the same lane is a related 32 A unit built for a TeSys U combination.

Selecting the ATS01N112FT for Oman and the GCC

  • Motor full-load current compared with 12 A and motor power with the table above.
  • Supply of 110–480 V (−10 / +10 %) at your site.
  • Soft stop needed? Only the QN versions list a deceleration time.
  • Enclosure space of 124 × 45 × 131 mm on a rail, and the 40 °C derating point in a warm switchroom.

Typical uses are small pumps, fans, compressors and conveyors on skids and utility cabinets in Gulf plants, where a gentle start protects belts, couplings and pipework. Fit it in a ventilated cabinet because summer ambient can approach the derating limit.

Information to send with an RFQ for the ATS01N112FT

  • Reference ATS01N112FT and quantity.
  • Motor power, full-load current, voltage and phases.
  • Need for soft stop and control voltage.
  • Ambient temperature and altitude.
  • Delivery location and deadline.

Documents and quotation

The manufacturer datasheet for the ATS01N112FT is attached on this page. It holds the full specification table, the dimension drawings and the mounting and wiring pages summarised above.

Send us the reference ATS01N112FT, the quantity and the delivery location and Seven Star LLC will reply to your request for quotation. We are an independent supplier based in Muscat.

Datasheets & Documents
  • PDF Datasheet Schneider Electric ATS01N112FT Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ATS01N112FT Altistart 01 Soft

Answers from our engineering team on installation, compatibility and integration.

01What is the rating of the ATS01N112FT?
The starter rating is 12 A, utilisation category AC-53B, with a voltage-ramp start and integrated bypass.
02Which motors can the ATS01N112FT start?
The datasheet lists 1.5 kW single-phase at 230 V; 2.2 kW three-phase at 230 V; 5.5 kW three-phase at 400 V.
03What supply does the ATS01N112FT use?
110-480 V (-10 / +10 %) with limits of 99-528 V. The control circuit can be 110 V AC, 24 V AC/DC or 240 V AC.
04Does the ATS01N112FT have a soft stop?
The datasheet lists no deceleration time, so it is a soft start only.
05What are the size and weight of the ATS01N112FT?
124 × 45 × 131 mm and 0.28 kg, IP20.