Lovato ADXL0115600 Soft Starter 115 A with Built-in Bypass

Description

Lovato ADXL0115600 soft starter, 115 A with built-in bypass

The Lovato ADXL0115600 is a 115 A soft starter with built-in bypass for three-phase motors on supplies of 208 to 600 V AC. Under IEC conditions it handles 55 kW at 400 V, 75 kW at 500 V and 37 kW at 230 V. Seven Star LLC supplies the ADXL0115600 in Oman and the GCC as an independent supplier in Muscat.

The code follows the ADXL pattern: 0115 gives 115 A and 600 the voltage class. Compared with the ADXL0060600 it is a larger body of 95 x 226 x 182 mm and 2.9 kg, but the control platform, the display and the protections are shared. That makes it practical to standardise on one family for several pump sizes.

ADXL0115600 technical specifications

Parameter Specification
Manufacturer / part number Lovato / ADXL0115600
Rated supply voltage 208 to 600 V AC, 50/60 Hz
Auxiliary supply 100 to 240 V AC
Rated current Ie 115 A
IEC motor power in-line 37 kW at 230 V; 55 kW at 400 V; 75 kW at 500 V
UL motor power 40 HP at 220-240 V; 60 HP at 380-415 V; 75 HP at 440-480 V; 100 HP at 550-600 V
Controlled phases 2
Bypass Built in
Trip classes Start: 2, 10A, 10 to 40; run: 2, 10A, 10 to 30
Interface Backlit LCD, NFC, optical port
Digital inputs / outputs 3 / 3
Operating temperature -20 to +60 °C; derate 0.5 percent per degree above 40 °C
Altitude 1000 m, then 0.5 percent per 100 m
Pollution degree 2; installation category III
Size and weight 95 x 226 x 182 mm; 2.9 kg
Protection IP00

Choosing the ADXL0115600 for larger pumps

At 55 kW the motor current approaches the range where direct starting causes voltage dips and mechanical shock. A soft starter reduces both. For a centrifugal pump the torque ramp gives a smooth acceleration and, with a soft stop, avoids the pressure surge on shutdown. For a compressor or conveyor the constant-torque start with current limit keeps the line current within the utility or generator limit.

Heavy starts raise the thyristor temperature. The thermal capacity depends on the starting current, the start time and the number of starts per hour, so a long start of 30 seconds at 4 times current requires a check against the manual curves or a larger unit.

Protection and diagnostics in the ADXL0115600

Besides motor overload, locked rotor, phase loss, asymmetry and dry-run detection, the starter reports its own faults: overtemperature of the thyristors, bypass failure and fan faults. The event log records the cause and a snapshot of values, which is valuable when a plant operator reports a trip without knowing why. A maintenance counter requests service after a set number of starts or hours.

Neighbours of the ADXL0115600

The ADXL0085600 handles 85 A and the ADXL0135600 handles 135 A, so a 55 kW motor with a high current can be matched to either size depending on nameplate. Above this range the ADXT family takes over with its 3-phase control and forced cooling.

ADXL0115600 selection checklist

  • Motor nameplate current and whether it is under 115 A
  • Supply voltage and frequency
  • Starting time and starts per hour
  • Auxiliary supply of 100 to 240 V AC
  • Cooling: natural or optional forced
  • Panel temperature and altitude derating
  • Available space of 95 x 226 x 182 mm

Installing and commissioning the ADXL0115600

Use the screw fixing or rail with the accessory, observe the clearances above and below for airflow, and wire line to the top and motor to the bottom as marked. Protect the starter with semiconductor fuses when coordination type 2 is wanted.

Set rated current, ramp times, current limit and trip class at the keypad. Verify the direction of rotation first on a bump start, then run the pump with the discharge valve in its normal start position. Record the settings.

Typical ADXL0115600 applications in Oman and the GCC

Typical uses are large water transfer pumps, desalination feed pumps, fans in tunnels and industrial buildings, and process compressors. The ability to limit starting current is valuable in remote sites supplied by diesel generators, where a hard start can cause a trip of the whole set.

A final point on coordination: the starter does not replace the short-circuit protection of the feeder. A fuse or breaker of the correct rating must still sit upstream, and when the plant requires the starter to survive a fault, semiconductor fuses chosen from the manufacturer tables are normally specified. Cable sizing follows the motor current, not the starter rating, so a 100 A motor on this starter needs a cable for 100 A at the site temperature. Keep a copy of the programmed parameters with the panel documents, because a replacement unit can then be set up in minutes.

Information to send with an RFQ for the ADXL0115600

  • Part number ADXL0115600 and quantity
  • Motor power, voltage, current
  • Load type and start duration
  • Starts per hour
  • Control supply
  • Delivery site

Site conditions in Oman for the ADXL0115600

Low-voltage switching and protection devices in Oman often sit in motor control centres and outdoor panels where internal temperatures are high for much of the year. When you select the ADXL0115600, check its rated values at your real ambient temperature, as stated in the manufacturer documentation, and confirm the coordination with upstream protection and with the motor or load it serves. Short-circuit levels differ from site to site, so verify the breaking capacity required at the point of installation.

Standardising ratings and coil voltages across a project reduces the number of spare part numbers that need to be stocked. Keeping a small stock of the ADXL0115600 and recording settings such as trip ranges or ramp times shortens repair work during a breakdown.

Documents and quotation

Send the part number ADXL0115600 and we will confirm the documents available for it, such as the technical data sheet, wiring diagram and instruction sheet, together with availability and lead time.

Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Share the quantity, delivery location and project reference with the request and we will answer with a formal quotation.

Other Models in the Lovato Adxl Softstarter Range

Seven Star LLC supplies models from the Lovato Adxl Softstarter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Lovato ADXL0075600 Soft Starter 75 A with BypassMotor Soft StartersView details
Lovato ADXL0060600 Soft Starter 60 A with Built-in BypassMotor Soft StartersView details
Lovato ADXL0115600 Soft Starter 115 A with Built-in BypassMotor Soft StartersYou are viewing this model
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.

Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.

Lovato Electric at a glance

Established 1922, Bergamo, Italy
Headquarters Gorle (Bergamo), Italy
Ownership Private, family-run for four generations
Product families Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs

Lovato products we list

Family Models Typical use
Contactors BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing Switching motors, heaters, lighting and capacitor banks
Motor protection and starters SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay Short-circuit and overload protection and direct starting of motors
Soft starters ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 Reducing starting current and mechanical shock on pumps, fans and compressors
Variable speed drives VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 Speed control of pumps, fans and conveyors to save energy
Power management and control DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC Power factor correction, mains/generator changeover and energy monitoring

Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.

Where Lovato products are used

In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.

Ordering Lovato products: what we need

Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.

Facts checked against Lovato Electric company profile brochures, October 2026.

FAQ

Questions about the Lovato ADXL0115600 Soft Starter 115 A with Built-in

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the ADXL0115600?
It is 115 A, which corresponds to 55 kW at 400 V and 75 kW at 500 V under IEC conditions.
02What size is the starter?
The catalogue gives 95 x 226 x 182 mm and a weight of 2.9 kg.
03Is a bypass built in?
Yes, the bypass is internal, so no external bypass contactor is needed for continuous running.
04What auxiliary supply does it need?
An auxiliary supply of 100 to 240 V AC is required for the electronics.
05How is it programmed?
Through the front keypad and backlit LCD, by NFC, or through the optical port.