Schneider Electric ATS22D47Q Altistart 22 Soft Starter 47 A

Description

ATS22D47Q: Altistart 22 soft starter for pumps and fans, 47 A

The ATS22D47Q is a Schneider Electric Altistart 22 soft starter for three-phase asynchronous motors, with the datasheet naming pumps and fans as the application. It is rated 47 A in the motor supply line, drives 11 kW at 230 V; 22 kW at 400 V and 440 V, and has a 230 V control circuit. This unit is a lifecycle-flagged product: the datasheet shows the status “To be discontinued on 31 Dec 2026”, with end of service planned for 29 Jun 2035, so confirm availability and plan a replacement path before committing it to a new design. Seven Star LLC supplies the ATS22D47Q in Oman and the GCC as an independent supplier based in Muscat.

The reference breaks down in a way that matches the datasheet: ATS22 is the range, D marks the 230 V control version, the digits (47) follow the starter rating of 47 A, and Q goes with the 230–440 V power supply. This is our reading, not a published ordering key.

ATS22D47Q compared with the other ATS22 ratings in this group

Reference Rating Motor at 400 V Size Weight Status
ATS22D32Q 32 A 15 kW 265 × 130 × 169 mm 7 kg Discontinued on 8 Jun 2026
ATS22D47Q 47 A 22 kW 265 × 130 × 169 mm 7 kg To be discontinued on 31 Dec 2026
ATS22D75Q 75 A 37 kW 295 × 145 × 207 mm 12 kg To be discontinued on 31 Dec 2026
ATS22D88Q 88 A 45 kW 295 × 145 × 207 mm 12 kg To be discontinued on 31 Dec 2026

All four share the 230 V control circuit, the torque-controlled start and the Modbus link. The ATS490 soft starters covered on neighbouring pages are a different family with a different supply and control arrangement.

Selection checklist and use of the ATS22D47Q in Oman and the GCC

  • Motor full-load current compared with 47 A, and the connection (line or delta) your wiring uses.
  • Power supply of 230–440 V and a 230 V control supply available at the panel.
  • Lifecycle status: to be discontinued on 31 dec 2026; check stock and a replacement plan.
  • Cabinet space for 265 × 130 × 169 mm and enough ventilation for 48 W of loss.
  • A type 12 or IP54 cabinet where dust is heavy.

This starter suits pumps and fans, for example water transfer, cooling and ventilation duty in Gulf plants, where gentle acceleration limits pipe surges and belt wear. Dusty sites need a filtered cabinet.

Torque-controlled starting on the ATS22D47Q

This unit starts the motor by torque control with the current limited to 3.5 times the nominal current, rather than by a plain voltage ramp. The output current can be set between 0.4 and 1 times the starter rating, and the factory setting for this reference is 42 A, so the first commissioning step is to adjust it to the motor nameplate. An internal bypass takes over at the end of the start, and the datasheet gives 48 W of dissipation for standard applications.

Connection is either in the motor supply line or to the motor delta terminals. The AC-3 power table in the datasheet gives 7–11 kW at 200–240 V; 15–25 kW at 380–440 V. Confirm the connection method with the motor terminal box layout.

Mounting and heat for the ATS22D47Q

This is a frame size A unit measuring 265 × 130 × 169 mm with a weight of 7 kg. Mount it within ± 10 degrees of vertical, leave free space so air can move from bottom to top, keep it away from heat-radiating parts, and arrange several starters in a row rather than stacking them, because heat from the lower unit raises the temperature around the upper one. Cooling is by forced convection, and the datasheet gives the noise level as 45 dB.

Ambient is −10 to 40 °C without derating and 40 to 60 °C with 2.2 % derating per degree. Altitude up to 1000 m is free of derating, with 2.2 % per additional 100 m up to 2000 m. The datasheet states pollution degree 2 and advises a type 12 or IP54 cabinet for pollution degree 3, which matters in dusty Gulf plants. Vibration, shock and EMC data (emissions level A) are listed, with certifications C-Tick, CCC, UL, CSA and GOST and CE marking.

Control, protection and communication on the ATS22D47Q

The control circuit runs from 230 V and draws 20 W. Two relay outputs, R1 and R2, can be assigned to running, alarm, trip, stopped, not stopped, starting or ready, rated 5 A at 250 V AC (resistive) or 2 A inductive. Three logic inputs (LI1 to LI3) work at 24 V, and a PTC probe input of 750 Ω brings in motor temperature. The datasheet lists protection against line phase failure and thermal protection of both the motor and the starter.

A Modbus RS485 multidrop link on an RJ45 connector runs at 4800, 9600 or 19200 bps and supports 31 installed devices, so the starter can be read or controlled from a PLC. The datasheet’s mounting pages require the starter to be fitted in an enclosure, since ATS22 units are open devices.

Technical specifications of the ATS22D47Q

Parameter Specification
Manufacturer / part number Schneider Electric / ATS22D47Q
Range of product Altistart 22
Application Pumps and fans
Lifecycle status To be discontinued on 31 Dec 2026; end of service 29 Jun 2035
Phases 3 phases
Power supply voltage 230–440 V (−15 / +10 %); limits 195–484 V
Frequency 50–60 Hz ± 10 %
Motor power 11 kW at 230 V; 22 kW at 400 V and 440 V
Starter rating (IcL) 47 A, in the motor supply line, standard applications
Factory setting current 42 A
Output current setting 0.4–1 Icl adjustable
Type of start Torque control, current limited to 3.5 In
Utilisation category AC-53a
Bypass Internal
Power dissipation 48 W, standard applications
Control circuit 230 V (−15 / +10 %), 50/60 Hz; 20 W
Outputs / inputs 2 relay outputs (R1, R2); 3 logic inputs; PTC probe input
Communication Modbus RS485, RJ45, 4800–19200 bps; up to 31 devices
Dimensions (H x W x D) 265 × 130 × 169 mm
Net weight 7 kg
Cooling Forced convection; 45 dB
Degree of protection IP20
Operating temperature −10 to 40 °C; 40–60 °C with 2.2 % derating per °C

Information to send with an RFQ for the ATS22D47Q

  • Reference ATS22D47Q and quantity.
  • Motor power, full-load current, voltage and the connection (line or delta).
  • Control voltage at the panel.
  • Whether the unit replaces an existing ATS22 and its reference.
  • Delivery location and deadline.

Documents and quotation

The manufacturer datasheet for the ATS22D47Q is attached on this page. It holds the full specification table, the dimension drawings and the mounting and wiring pages summarised above. The datasheet carries the lifecycle notice summarised above.

Send us the reference ATS22D47Q, the quantity and the delivery location and Seven Star LLC will reply to your request for quotation. We are an independent supplier based in Muscat.

Other Models in the Se Altistart 22 Range

Seven Star LLC supplies models from the Se Altistart 22 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric ATS22D32Q Altistart 22 Soft Starter 32 AMotor Soft StartersView details
Schneider Electric ATS22D47Q Altistart 22 Soft Starter 47 AMotor Soft StartersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric ATS22D47Q Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ATS22D47Q Altistart 22 Soft

Answers from our engineering team on installation, compatibility and integration.

01Is the ATS22D47Q still current?
The datasheet shows the status 'To be discontinued on 31 Dec 2026' and end of service on 29 Jun 2035, so confirm availability before design-in.
02What motors does the ATS22D47Q drive?
The datasheet lists 11 kW at 230 V; 22 kW at 400 V and 440 V, with a starter rating of 47 A in the motor supply line.
03What control supply does the ATS22D47Q need?
A 230 V control circuit (-15 / +10 %), 50/60 Hz, drawing 20 W.
04How does the ATS22D47Q start the motor?
By torque control with current limited to 3.5 In. The factory setting current is 42 A and can be adjusted from 0.4 to 1 Icl.
05What are the size and weight of the ATS22D47Q?
265 × 130 × 169 mm and 7 kg, IP20, forced convection cooling.